Extended Features

Beyond the basic functions, Smart Building Automation can be adapted to individual requirements with additional functions.

Alarm System

The "Alarm System" app enables the configuration of an individual alarm system for the Smart Building Automation System. The alarm system is divided into a central alarm system and one or more alarm groups. Alarm groups divide the alarm system into several areas.

The app "alarm system" is located under "all apps" – "alarm system".

Configuration

Duration of silent alarm
Enter the time for silent alarm here.

Automatically deactivate alarm after
Automatically deactivates the alarm after expiration of this time. This is important if you are holiday and something triggers the alarm. If this option was not available, the alarm would never switch off and your neighbours would not be too pleased with you.

Duration of patrol
This is the time the alarm should be deactivated for while you make a patrol.

Button to activate the alarm system
Select a button to activate the alarm system.

Button to deactivate the alarm system
Use the button “add” to select a button to deactivate the alarm system. Warning! This button can deactivate the alarm system without a password. Consider the use of such a button carefully.

Button to start patrol
Select a button to let you start a patrol.

Button to end patrol
Select a button to tell the system you have completed your patrol.

Status light
Select a light that will flash twice when the alarm system has been activated and once when deactivated.

Actions when alarm triggers
Use the button “add” to select all the actions you wish to happen when an alarm is triggered (e.g. switch lights on, activate siren, etc.).

Actions when alarm stops
Select what should happen when the alarm is deactivated. Caution! Do not forget to deactivate the actions started when the alarm was triggered.

Change password
Change the password to deactivate your alarm system.

Operate

The initial password for the Alarm System is set to "1234".

It is highly recommended to change it on initial setup. You can find the related options in the SettingsPanel (See section configuration).

If the alarm system or one or more alarm groups have been activated, the defined activation delay for each alarm group must first expire before the alarm can be triggered. Once the activation delay has expired, if a movement detector is triggered then a trigger delay is activated. During this time, the alarm system can be de-activated without an alarm being triggered. Once the trigger delay has expired, the silent alarm is triggered and a notification is sent. Once the silent alarm time has expired, the actual alarm is triggered and a further notification is sent and the outputs linked to the alarm system are switched.

Activation time is necessary for the following situation: you want to leave the house and activate the alarm before you go. To make sure that you do not inadvertently trigger the alarm yourself, you need the activation delay.

If you want to activate the alarm system, you can either do this via the app by opening the alarm system (“all apps” –“alarm system”) and select the button “activate” in the operator panel for the alarm system, or you define a button to activate the alarm and you use this button (how you do this is described in the chapter configuration). Deactivating the alarm is done the same way via the app, only that you have to enter a password. Deactivation via a button works identically to activation.

You can also find a history of past events in the OperatorPanel of the alarm system which gives you detailed records about the dates and times when it got triggered, activated or deactivated.

Warning, since the alarm system can be deactivated without a password using a button, you need to select a button that is not immediately visible!

Szenen

Das Alarmsystem bietet folgende Auslöser für Szenen (wenn ...):

  • Alarm wurde ausgelöst: Der Alarm wurde durch einen konfigurierten Auslöser aktiviert
  • Alarm wurde gestoppt: Der Alarm wurde gestoppt
  • Alarm wurde still ausgelöst: Der stille Alarm wurde ausgelöst
  • Alarmsystem ist aktiviert: Das Alarmsystem wurde aktiviert
  • Alarmsystem wurde deaktiviert: Das Alarmsystem wurde deaktiviert

Das Alarmsystem bietet folgende Funktionen für Szenen (dann ...):

  • Aktivieren: Das Alarmsystem wird aktiviert (Achtung: die Alarmgruppe muss zusätzlich aktiviert werden).
  • Deaktivieren: Das Alarmsystem wird deaktiviert (Die Alarmgruppe bleibt aktiviert)
  • Kontrollgang beenden: Die Funktion „Kontrollgang“ wird beendet, das Alarmsystem wird wieder scharf geschaltet.
  • Kontrollgang starten: Die Funktion „Kontrollgang“ wird für die eingestellte Dauer aktiviert.
  • Alarmgruppe aktivieren: Die ausgewählte Gruppe wird scharf geschaltet.
  • Alarmgruppe deaktivieren: Die ausgewählte Gruppe wird unscharf geschaltet.

Alarm Group

An "Alarm Group" represents a section of your alarm system which you want to secure. You can create an unlimited number of groups and use them to arrange your house into various segments. This makes it possible to create different settings for each group and only activate the ones you need.

You can, for example, create a new alarm group for each floor and by using a scene, only secure the ones which are not occupied at the moment.

Operation

The OperatorPanel shows you the current state of the group. If the lock is closed, the group is currently active and will be taken into account when you activate the alarm system.

To change the state of the group, you can click on the small lock in the ObjectPanel of the group or use the button in the OperatorPanel.

Be aware that once the alarm system is activated, you can not change the state of each alarm group. If you want to activate or deactivate a group, you will have to deactivate the alarm system first.

Configuration

Activation delay
If the alarm system and this group have been activated, then the alarm in this group can only be triggered after this time has expired. (Important if you wish to leave the house without triggering an alarm yourself).

Trigger delay
The silent alarm is triggered after this time has expired.

Trigger if
Select all the triggers that you wish to be able to set off this alarm.

camera
Select one or more cameras which will capture up to 6 images if the alarm goes off. You can change the interval for the captured images by using the provided slider. For example: If you set the interval to 2 seconds, each camera will try to capture an image every 2 seconds until 6 images are recorded. You can view the captured images in the "pictures" section below this setting.

Test alarm
The button “test alarm” lets you trigger an alarm in this group. The group and the central alarm system are activated, the panel is closed and an alarm is triggered. Use this to test your alarm system.

Amazon Alexa

Alexa ist ein digitaler Sprachassistent von Amazon, der Sprachbefehle verarbeitet und abhängig von der jeweiligen Anwendung Antworten liefert oder verbundene Dienste steuert. Die Sprachbefehle werden dazu aufgezeichnet, an die Server von Amazon übertragen und dort verarbeitet. Anschließend werden die entsprechenden Funktionen ausgeführt oder Antworten bereitgestellt.
Alexa ist nicht an ein bestimmtes Gerät gebunden, sondern als Dienst auf verschiedenen von Amazon unterstützten Geräten und Plattformen verfügbar.

Alexa ist unter anderem bereits auf folgenden Geräten und Plattformen verfügbar:

Amazon Echo (Echo Dot, Echo, Echo Plus, Echo Show, Echo Spot)
Fire TV (Fire TV Stick, Fire TV)
Fire-Tablet (Fire 7, Fire HD 8, Fire HD 10)
Mobile Apps (Amazon Music App)

Zusätzlich zu den Grundfunktionen von Alexa, wie dem Abspielen von Musik oder der Beantwortung von Wissensfragen, kann der Funktionsumfang über sogenannte „Skills“ erweitert werden. Diese sind im „Alexa Skills Shop“ über https://alexa.amazon.de oder die offizielle Amazon Alexa App verfügbar.

Smart Building Automation bietet eine Integration von Alexa in Form eines „Smart Home Skill“ an. Damit können Geräte und Szenen über Sprachbefehle gesteuert werden. Folgende Geräte und Funktionen werden unterstützt:

  • Licht
  • Jalousie
  • Heizung
  • Steckdosen
  • Szenen

Weitere Informationen sind in den folgenden Abschnitten zu finden.

Erstellen

Für die Verwendung von Alexa mit dem Smart Building Automation System wird ein Alexa-kompatibles Gerät (z. B. Fire TV oder Amazon Echo) benötigt. Zusätzlich muss das System mit einem funktionsfähigen Netzwerk mit Internetzugang verbunden und der „Externe Zugriff“ aktiviert sein.

Da alle an Alexa gerichteten Befehle zuerst an die Server von Amazon übermittelt werden, ist die Verwendung von Alexa ohne Internetzugang derzeit nicht möglich.

Vor Beginn der Einrichtung muss sichergestellt werden, dass der „Externe Zugriff“ im Smart Building Automation System aktiviert ist. Die Zugangsdaten (ID, Benutzername, Passwort) werden in den folgenden Schritten benötigt.

Für die Verbindung von Amazon Alexa mit dem Smart Building Automation System muss der „evon Smart Home Smart Home Skill“ aus dem Alexa Skills Shop geladen werden. Dafür kann die offizielle Amazon Alexa App auf einem Smartphone oder Tablet verwendet werden. Alternativ ist die Einrichtung auch über https://alexa.amazon.de im Browser möglich.

Zur Aktivierung des „evon Smart Home Smart Home Skill“ ist eine Anmeldung mit den Zugangsdaten des Smart Building Automation Systems erforderlich. Dazu erfolgt eine Weiterleitung auf die Login-Seite des Systems, auf der die Zugangsdaten eingegeben werden können. Nach erfolgreicher Anmeldung wird der „evon Smart Home Smart Home Skill“ aktiviert und die Einrichtung kann mit dem nächsten Schritt fortgesetzt werden.

Nach der Aktivierung startet Alexa die Suche nach kompatiblen Geräten und Szenen. Die Suche kann auch später über die offizielle Amazon Alexa App oder die zugehörige Website erneut gestartet werden.

Nach Abschluss der Suche werden alle gefundenen Geräte (z. B. Lichter) aufgelistet. Diese können anschließend über Sprachbefehle gesteuert werden (siehe Abschnitt „Bedienung“).

Configuration

Bedienung

Alle Befehle müssen mit „Alexa“ beginnen. Dadurch wird Alexa geweckt und hört nun auf den folgenden Satz. Einige Geräte (und Apps) wie der Echo, haben zusätzlich eine eigene Taste, über die Alexa ebenfalls aktiviert werden kann, wodurch „Alexa“ nicht mehr zu Beginn des Befehls genannt werden muss.

Der „evon Smart Home Smart Home Skill“ verwendet die von Amazon bereitgestellte „Smart Home Skill API“. Die verfügbaren Sprachbefehle werden daher von Amazon vorgegeben. Da Amazon Alexa regelmäßig aktualisiert und erweitert, können Sprachbefehle hinzugefügt, geändert oder entfernt werden. Auch die möglichen Formulierungen einzelner Befehle können sich ändern oder erweitert werden (z. B. Licht einschalten: „aktiviere“, „schalte ein“ etc.).

Im Folgenden sind die verfügbaren Sprachbefehle zur Steuerung der Geräte im Smart Building Automation System aufgelistet.

Licht (Ein/Aus, Dimmen, Farbe)

  • Alexa, schalte Lichtname ein
  • Alexa, schalte Lichtname aus
  • Alexa, stelle Lichtname auf 30 Prozent
  • Alexa, erhöhe Lichtname um 20 Prozent
  • Alexa, senke Lichtname um 40 Prozent
  • Alexa, stelle Lichtname auf rot

Jalousie (Position)

  • Alexa, stelle Jalousiename auf 30 Prozent

Heizung (Temperatur)

  • Alexa, stelle Heizungsname auf 22 °C
  • Alexa, erhöhe Heizungsname um 4 °C
  • Alexa, senke Heizungsname um 2 °C

Steckdose (Ein/Aus)

  • Alexa, schalte Steckdosenname ein
  • Alexa, schalte Steckdosenname aus

Szenen (Aktivieren)

  • Alexa, starte Szene Szenenname

Allergie Assistent

Der Allergie Assistent hilft Ihnen dabei, Ihre nervigen Allergien in den Griff zu bekommen. Anhand Ihrer persönlichen Konfiguration ermittelt der Allergie Assistent die aktuelle Pollenbelastung sowie eine Prognose für die nächsten Tage. Dabei werden Kriterien wie z.B. Ihre Region, Regen und Wind berücksichtigt. Wenn Sie möchten, kann der Allergie Assistent Sie über Veränderungen der Belastung, oder geöffnete Fenster bei Pollenbelastung benachrichtigen.

Sie finden Allergy Pro unter "Alle Apps" - "Allergie Assistent"

Konfiguration

Der Allergie Assistent existiert bereits und muss daher nicht mehr erstellt werden. Die Konfiguration können Sie mit wenigen Klicks ganz einfach vornehmen.

Durch Klick auf das ObjectPanel öffnet sich ein Wizard. Mithilfe des Wizards, können Sie den Allergie Assistent ganz einfach konfigurieren.

Nach dem Beginnen der Konfiguration können Sie auswählen, welche Allergien Sie haben. Damit ist der Allergie Assistent auf Sie abgestimmt.

Damit Sie nur dann Benachrichtigungen erhalten wenn Sie es auch wollen, können Sie diese im nächsten Schritt konfigurieren.

Zusätzlich können Sie die Region auf Ihren Wohnort einstellen. Dadurch kann der Allergie Assistent Sie noch präziser unterstützen.

Ihre persönliche Konfiguration können Sie ab jetzt im Parameter Panel des Allergie Assistent jederzeit ändern.

Bedienung

Mit dem Allergie Assistent haben Sie die aktuelle Pollenbelastung immer im Blick. Ein Index von 0 bis 3 zeigt Ihnen, wie stark die aktuelle Belastung ist. Ein Index von 0 bedeutet, dass keine Belastung vorliegt, während bei 3 eine maximale Belastung erreicht wurde. Sie können natürlich die aktuelle Belastung in der Logik verwenden oder mithilfe von Szenen auf Änderungen reagieren.

Die Aktuelle Belastung können Sie beispielsweise rechts im ObjectPanel ablesen.

Im Operator Panel wird Ihnen neben der aktuellen Belastung auch eine Prognose für die nächsten 3 Tage angezeigt.

Jeden Tag haben Sie einmal die Möglichkeit, Ihr aktuelles Empfinden hinsichtlich Ihrer Allergien abzugeben. Dies hilft dabei, den Allergie Assistent zu verbessern und Sie in Zukunft noch besser zu unterstützen.

Im unteren Bereich des Operator Panels erhalten Sie hilfreiche Tipps, um Sie vor Pollen zu schützen. Durch Klick auf „Nächster Tipp“, können Sie weitere Tipps erhalten.

Im Parameter Panel können Sie die Konfiguration jederzeit ändern.

Ganz unten befindet sich ein Button, mit dem Sie den Allergie Assistent wieder komplett zurücksetzen können.

Analog Output

An analog output outputs voltages in the range 0-10V. To do this, enter a value in your defined area and this will be output as a voltage between 0-10V.

The analog outputs can be found under “all apps” –“analog output”.

Configuration

Minimum/Maximum
The calculated value is in the range between the minimum and maximum. This means that if 10V are meant to be present on the module output, then the value must be set to the defined maximum value (100%).

Number of decimal places
Defines the number of decimal places for the calculation.

Dimension
Define here what you wish to control with this analog output (e.g. speed: %)

Stored value upon bus error
If the control were to fail, the last value would be stored if you have activated this option. If you did not activate this option, the value present when the control failed will be lost.

Szenen

Der Analoge Ausgang bietet folgende Funktionen für Szenen (dann ...):

  • Wert schreiben: Ein frei definierbarer Wert kann auf den analogen Ausgang geschrieben werden

Data Description

Raw value
The raw value is the voltage 0-10 V that is present (set) on the output of the module.

Raw value (phys.)
This is the digital value sent to the module.

Value
This is the scaled value that has been converted to the defined range between minimum and maximum, with the defined number of decimal places and the defined dimension.

Setting Values

There are two different possibilities to set a value to the analog output. Either you set the value via the operator panel for the analog output, or you select the analog output in a scene for the “if …” statement and then select “write value”. Then you can change the value by clicking on the pencil.

Analog Input

An analog input can measure voltage in the range 0-10V. This voltage is then scaled to the range defined by the user. This value can be used by the user for calculations (using logic), or simply to trigger scenes if the value exceeds or falls below certain (definable) limits.

The analog inputs are located under “all apps” – “analog inputs”.

Configuration

Minimum/Maximum
Minimum and maximum limits of the measured value. These inputs must be taken from the description of the sensor used. For example, you wish to measure the humidity in a room and use a sensor with a 0-10V output signal. The sensor documentation tells you that the sensor can measure humidity from 0% to 100%. The minimum limit is hence 0 and the maximum limit is 100.

Number of decimal places
Indicates the number of decimal places used to calculate the value.

Dimension
This is where you define exactly what you wish to measure with this analog input (e.g. temperature °C).

Notification on limit violation
If the value of the analog input falls below the lower limit or exceeds the upper limit, then you will be notified by the system if this checkbox is activated.

Upper limit
Enter the upper limit here. If the value exceed this limit, you can react with a scene by selecting the trigger for “value above upper limit” in the “IF …” statement.

Lower limit
Enter the lower limit here. If the value falls below this limit, you can react with a scene by selecting the trigger for “value below upper limit” in the “IF …” statement.

Szenen

Der Analoge Eingang bietet folgende Auslöser für Szenen (wenn ...):

  • Obere Grenze wurde überschritten: Die parametrierte obere Grenze wurde vom Messwert überschritten
  • Untere Grenze wurde unterschritten: Die parametrierte untere Grenze wurde vom Messwert unterschritten

Data Description

Raw value
A raw value is the voltage (0-10V) measured on the input of the module.

Raw value (phys.)
Corresponds to the output of an analog/digital converter and is used for the calculation into the physical measured value.

Value
Corresponds to the scaled value resulting from the raw value, minimum and maximum.
Value = (Raw value phys. / Raw value phys. MAX) * (Maximum – Minimum) + Minimum.

The Operatorpanel of the selected Analog Input also provides you with a chart, which keeps track of the measured values.

Simulation

If you wish to simulate the value for an analog input, this is easily done by activating the option “simulation on” in the operator panel and selecting the desired value in the slider. This can be useful if you have defined a scene you wish to be carried out if a limit is exceed and you wish to test what happens.

Anwesenheitssimulation

Die Anwesenheitssimulation soll trotz Abwesenheit (z.B.: Urlaub) das Eigenheim bewohnt aussehen lassen und somit als Schutz vor Einbruch dienen. Um die Anwesenheit bestmöglich zu simulieren wird das gewohnte Verhalten aufgezeichnet und lokal auf Ihrem Controller gespeichert. Diese Daten werden dann verwendet, um eine intelligente Simulation der Anwesenheit zu ermöglichen.

Sie finden die Anwesenheitssimulation unter „Alle Apps“ - „Anwesenheitssimulation"

Konfiguration

Die Anwesenheitssimulation existiert bereits und muss daher nicht mehr erstellt werden. Die Konfiguration können Sie mit wenigen Klicks ganz einfach vornehmen.

Durch Klick auf das ObjectPanel öffnet sich ein Wizard. Mithilfe des Wizards, können Sie die Anwesenheitssimulation ganz einfach konfigurieren.

Im ersten Konfigurationsschritt können die Lichter ausgewählt werden, welche in die Simulation aufgenommen werden sollen. Wenn Sie bestimmte Lichter (z.B.: Kellerräume, etc.) von der Anwesenheitssimulation ausnehmen wollen, können Sie dies indem Sie die Checkbox „Alle auswählen“ abhaken und die einzelnen Lichter in der Liste manuell auswählen.

In diesem Schritt können die Beschattungselemente für die Anwesenheitssimulation konfiguriert werden. Wenn Sie bereits eine automatische Beschattungsregelung konfiguriert haben, müssen Sie entscheiden ob während der Simulation die automatische Beschattungsregelung oder die Anwesenheitssimulation zur Steuerung der Elemente verwendet werden soll. Der Unterschied besteht darin, dass die Anwesenheitssimulation nicht auf die aktuelle Sonneneinstrahlung reagiert, sondern vergangene automatische und manuelle Bedienungen der Elemente wiedergibt.
Wie auch bei den Lichtelementen können Sie entscheiden, ob Sie alle Elemente oder nur bestimmte für die Anwesenheitssimulation verwenden möchten.

Optional können Sie auch beliebige digitale Ausgänge (z.B.: TV-Steckdose) in die Simulation aufnehmen. Klicken Sie hierzu einfach auf hinzufügen und wählen Sie die gewünschten Elemente aus.

Achten Sie darauf, dass Sie keine sicherheitsrelevanten Elemente wie Türöffner o.Ä. in die Auswahl aufzunehmen!

Der aktivierte Zufallsmodus schaltet zusätzlich zu den aufgezeichneten Ereignissen die Lichter auch in einer zufälligen Folge (z.B.: Licht Gang um 23:00 für 5min ein). Die Lichter werden im Zufallsmodus maximal 10 Minuten aktiviert.

In diesem Schritt können Sie allgemeine Einstellungen der Anwesenheitssimulation konfigurieren. Die Einstellung „Mit Hausstatus verknüpfen“ ermöglicht das automatische Aktivieren der Simulation, wenn der Hausstatus „Urlaub“ aktiviert wurde. Beim Verändern des Hausstatus wird zudem die Simulation automatisch deaktiviert.

Die Simulation funktioniert nach dem Aktivieren den gesamten Tag, Sie können jedoch auch einen Zeitbereich wählen in welchem die Simulation aktiv sein soll.

Die Konfiguration ist erfolgreich abgeschlossen! Die Aufzeichnung wird im Anschluss automatisch gestartet. Für eine vollständige Simulation muss die Aufzeichnung ca. 1 Woche ausgeführt werden. Möchten Sie die Simulation jedoch bereits früher nutzen können Sie mit eingeschränkten Funktionen bereits nach 1-2 Tagen starten.
Die aufgezeichneten Daten werden automatisch aktualisiert, Sie müssen die Konfiguration somit nicht erneut ausführen.

Bedienung

Wenn Sie die Anwesenheitssimulation mit dem Hausstatus „Urlaub“ verknüpft haben, wird diese automatisch aktiviert, sobald Sie diesen Hausstatus aktivieren.
Alternativ haben Sie die Möglichkeit, mithilfe der Szenen „Simulation aktivieren“ und „Simulation deaktivieren“ zu steuern.
Sie können die Simulation natürlich im OperatorPanel der Anwesenheitssimulation selbst auch aktivieren.

Achten Sie darauf, dass die Aktivierung mittels Hausstatus oder Szene erst dann funktioniert, wenn ausreichend Daten aufgezeichnet wurden.

Sobald Sie die Anwesenheitssimulation konfiguriert haben, beginnt diese Ihr Verhalten aufzuzeichnen.

Der aktuelle Status der Anwesenheitssimulation wird im ObjectPanel dargestellt.

Im OperatorPanel wird der aktuelle Status, sowie der Aufzeichnungsfortschritt dargestellt.

Sobald ausreichend Daten aufgezeichnet wurden, kann die Anwesenheitssimulation durch Klick auf den Button „Simulation Starten“ gestartet werden.

Wenn die Anwesenheitssimulation aktiv ist, wird Ihnen dies am oberen Bildschirmrand der Startseite angezeigt. Somit haben Sie den Status der Anwesenheitssimulation immer im Blick.

Im ParameterPanel können alle Einstellungen, welche im Wizard konfiguriert werden geändert werden.

Zusätzlich können die Elemente, welche für die Simulation verwendet werden bearbeitet werden.

Achtung: Wenn neue Elemente ausgewählt werden, kann es einige Tage dauern, bis diese in der Simulation mit berücksichtigt werden

Durch Klick auf „Anwesenheitssimulation zurücksetzen“ werden alle Einstellungen zurückgesetzt und gespeicherte Daten gelöscht. Sie können die Anwesenheitssimulation danach jederzeit neu konfigurieren.

Bathroom Heating

“Bathroom heating” lets you configure suitable heating systems and control their times.

These functions are located under “all apps” – “bathroom heating”.

Operation

To add a new bathroom heater, click on the element “add”. First allocate a name to your bathroom heater in the parameter panel, then you can continue with the configuration (described below).

Szenen

Der Badheizkörper bietet folgende Auslöser für Szenen (wenn ...):

  • Wurde Ausgeschaltet: Der Badheizkörper wurde ausgeschaltet
  • Wurde Eingeschaltet: Der Badheizkörper wurde eingeschaltet

Der Badheizkörper bietet folgende Funktionen für Szenen (dann ...):

  • Einmalig einschalten: Der Badheizköper wird für die Zeit des zusätzlichen Auslösers eingeschaltet

Configuration

You can determine what time each of your bathroom heaters should be on. You do this by defining the operating times in the operator panel. You can define one or more time intervals where your heater should heat for each weekday.

Apart from the operating times, you can also define a button to activate each bathroom heater, where it is connected and whether it should be switched into maintenance mode.

Additional trigger
Select the trigger and the duration for which the bathroom heater should additionally be activated for a short period of time.

Select socket
This lets you define which socket your bathroom heater is connected to.

Maintenance mode
This lets you permanently switch the maintenance mode for the bathroom heater on or off.

Blind

The app “Blinds” lets you operate and configure all shading elements in your system. You also have pre-defined functions such as “open all blinds” and “close all blinds”.

You can find Blinds under “all apps”.

Usage

You can open or close your shading element using the arrows in the left-hand side of the object panel. The right-hand side of the panel shows the current position and the angle of the blinds.

You can also operate each blind element via the operator panel by using the sliders on the right and on the left, or dragging the point in the middle of this window to the desired position. If you have defined a favourite position and wish to use it, simply click on the button “go to favourite position”.

Szenen

Die Beschattung bietet folgende Funktionen für Szenen (dann ...):

  • Alle auf erste Favoriten Position fahren: Alle Beschattungselemente werden auf die jeweils erste eingestellte Favoriten Position gefahren
  • Alle auf Position fahren: Alle Beschattungselemente werden auf eine frei definierbare Position und einen frei definierbaren Lamellen-Winkel gefahren
  • Alle stoppen: Alle Beschattungselemente werden gestoppt
  • Alle öffnen: Alle Beschattungselemente werden geöffnet
  • Alle schließen: Alle Beschattungselemente werden geschlossen
  • Auf Favoriten Position fahren: Das Beschattungselement wird auf die definierte Favoriten Position gefahren.
  • Auf Position fahren: Das Beschattungselement wird auf eine frei wählbare Position und einen frei wählbaren Lamellen-Winkel gefahren
  • Auf Winkel stellen: Das Beschattungselement wird auf einen frei wählbaren Lamellen-Winkel gefahren
  • Öffnen: Das Beschattungselement wird vollständig geöffnet
  • Schließen: Das Beschattungselement wird vollständig geschlossen
  • Stoppen: Das Beschattungselement wird gestoppt
  • Um X Prozent öffnen: Das Beschattungselement wird um die definierte Prozentzahl geöffnet
  • Um X Prozent schließen: Das Beschattungselement wird um die definierte Prozentzahl geschlossen

Beschattungselemente können unter den erweiterten Einstellungen von Universalszenen ausgenommen werden. Für ausgenommene Elemente werden die Szenen-Funktionen „Alle...“ nicht angewendet.

Configuration

Apart from giving the shading elements individual names, you can customize them further to suit your needs.

Settings

Mode
This option is available when the Schrack Smart Building Automation shading module "B1344" (Schlotterer RETROLux) is used. The operating mode can be changed from "standard blind" to "without working position" or "with working position". In this context, "working position" refers to a blind with a mechanical working position.

With working position
This mode is intended for Schlotterer RETROLux venetian blinds with a mechanical working position. A short button press changes the slat position and allows switching between "closed" and "working position". In this mode, the slats can only be adjusted within a certain range due to the mechanical design of the blind.

Without working position
This mode is intended for Schlotterer RETROLux venetian blinds without a mechanical working position. This mode grants you the ability to simulate a working position.

Type
This setting defines whether the shading element is a rolling shutter or a window. Windows are described in a separate chapter. A jalousie has a position, slat angle, and turnaround time, all of which are taken into account during movement. A roller shutter does not have a slat angle.

Vertical jalousie
This setting can be used for a jalousie that opens and closes vertically. When activated, an additional option is available for defining the opening direction.

Remove from universal scene
Universal scenes can be used, for example, to "open all blinds". Activate this option to exclude the shading element from universal scenes.

Remove from wind-lock
Activate this option to prevent the blind from opening automatically during strong winds. If this option is not available, the wind-lock must first be activated under "all-apps – settings – shading".

Lock blind
Activate this option to lock the blind. While locked, the shading position cannot be changed via the app or a button.

Close at dusk
Activate this option to automatically close the shading element at dusk.

Reserve
If a module has unused outputs, the corresponding shading elements are still displayed. The reserve function can be used to hide these unused elements in the app. To display them again, activate the corresponding elements in the module under the hardware section.

Extended parameter
When the Schrack Smart Building Automation shading module "B1344" is used in combination with a Schlotterer venetian blind and the appropriate operating mode is selected, additional options are available here.

These options relate to the different movement times specific to Schlotterer blinds, such as the working position and snapping times. The settings are preconfigured for optimal operation. If problems occur when switching between positions, contact the Smart Building Automation partner responsible for the system to have these settings adjusted.

Travel Times

Travel time wizard
This wizard lets you easily and simply determine the travel times for your shading element. Simply follow the instructions and your travel times will be configured for you.

Use these travel times for all blinds
Pressing this button opens a dialog where you can have all blinds use these travel times. This is useful if all blinds are of the same type and you do not wish to have individual times for each blind.

Favorite Position

You can save your favourite blind position either by entering the values by hand or pressing the button “use current position as favourite”. The favourite position can be triggered via a scene.

Erweiterte Einstellungen

Windsperre:
Von Windsperre ausnehmen
Wenn Sie nicht wollen, dass sich ein Beschattungselement bei zu starkem Wind öffnet, so müssen Sie diese Option aktivieren. Wenn diese Option nicht sichtbar ist, so müssen Sie erst in den Einstellungen (Alle Apps – Einstellungen – Beschattung) die Windsperre aktivieren.

Sperren bei übertreten der Grenze
Wenn das Beschattungselement bei zu starkem Wind gesperrt werden soll kann hier bestimmt werden, ob diese bei der Haupt-Windgrenze, Windgrenze 1 oder Windgrenze 2 gesperrt werden soll. Die Grenzen können unter Einstellungen > Globale Einstellungen definiert werden.

Nach Windalarm wieder auf letzte Position fahren:
Wenn Sie wollen, dass ein Beschattungselement nach dem Windalarm wieder auf die letzte Position fährt, so müssen Sie diese Option aktivieren. Wenn diese aktiviert wurde, erscheint ein Eingabefeld, in dem Sie eine Verzögerungszeit von 5 bis 60 Minuten wählen können, welche ablaufen muss, bevor die Beschattung nach dem Windalarm auf die letzte Position zurück fährt.

Allgemeine Parameter:
Vertikale Jalousie
Wenn Sie eine Jalousie haben, die vertikal schließt bzw. öffnet, so können Sie dies hier einstellen. Haben Sie dies aktiviert, erscheint eine weitere Option mit der Sie die Öffnungsrichtung bestimmen können.

Von Universalszene ausnehmen
Als Universalszene gilt z.B. „Alle öffnen“. Wollen Sie aber, dass ein Beschattungselement nicht über diese Universalszenen mitgeschalten wird, so müssen Sie diese Option aktivieren.

Beschattung sperren
Mit dieser Option können Sie ein Beschattungselement sperren. D.h. die Position des Beschattungselementes kann nicht mehr über die App oder Taster verändert werden.

Globalen Modus überschreiben
Mit der Option können Sie für diesen Kanal den globalen Modus für die Steuerung mittels Taster überschreiben (Kurzer Tastendruck - ganz auf, Kurzer Tastendruck - Lamellen stellen)

Bei Dämmerung schließen
Wollen Sie, dass sich dieses Beschattungselement bei Dämmerung schließt, so müssen Sie diese Option aktivieren.

Reserve
Wenn Sie ein Modul haben, an dem Sie nicht alle Beschattungselemente angeschlossen haben, werden trotzdem auch die Elemente angezeigt, an denen nichts angeschlossen ist. Mit Reserve können Sie nicht verwendete Beschattungselemente in der App ausblenden. Über die Hardware und das entsprechende Modul können Sie dieses Beschattungselement wieder einblenden.

Linking

Linking allows shading elements to be connected to other elements in the Smart Building Automation system.

Connect with
To keep two shading elements at the same position and slat angle, use "connect with". Navigate to "connect with" and select "select" to choose the shading element to be connected.

Gruppenfunktion

Über die Gruppenfunktion lassen sich mehrere Beschattungen zu einer Gruppe zusammenfassen. Dadurch werden alle gleichzeitig geschalten.

Um eine neue Beschattungsgruppe anzulegen, wählen Sie „Neue Beschattungsgruppe“ innerhalb der Beschattungs-App.

Eine neue Beschattungsgruppe wird erstellt.

In den Einstellungen der Gruppe sollten Sie als erstes einen Namen vergeben und einen Raum zuordnen.

Hier haben Sie außerdem die Möglichkeit, die Gruppe zu deaktivieren. Dadurch können Sie eine bereits konfigurierte Gruppe temporär abschalten, ohne sie löschen zu müssen.

Fügen Sie nun mehrere Beschattungselemente hinzu. Sie habe die Möglichkeit die Gruppe in 2 Betriebsarten zu betreiben: „Starre Kopplung“ oder „Lose Kopplung“.

Starre Kopplung: Starre Kopplung: Dieser Modus ist sinnvoll, wenn Sie Beschattungselemente der gleichen Größe (Fensterhöhe) zu jedem Zeitpunkt auf derselben Position wünschen. Alle Beschattungselemente einer Gruppe fahren somit immer auf dieselbe Position und den Lamellenwinkel (falls vorhanden). Dabei ist es unerheblich ob der Befehl als Einzelbefehl über die App, als Gruppenbefehl über die App, den Autark-Taster oder den Gruppentaster erfolgt ist, die Position wird immer synchronisiert.

Lose Kopplung: Dieser Modus erlaubt das gemeinsame Heben und Senken von unterschiedlichen Beschattungselementen über einen oder mehrere Gruppentaster. Die Beschattungselemente können aber jederzeit über Einzelbefehle aus der App oder den Einzeltaster (Autarkfunktion) individuell positioniert werden.

Bei einer Beschattungsgruppe mit starrer Kopplung können Sie im Operator Panel mit den gewohnten Bedienelementen die Beschattungen in beliebige Positionen bewegen, öffnen, schließen und stoppen.

Bei einer Beschattungsgruppe mit loser Kopplung können Sie im Operator Panel die Beschattung öffnen, schließen und stoppen.

Bei Beschattungsgruppen mit loser Kopplung haben Sie zusätzlich die Möglichkeit andere Beschattungsgruppen hinzuzufügen. Dadurch ist es möglich mehrere Beschattungsgruppen mit externen Tastern zeitgleich zu steuern, diese Gruppen jedoch auch noch getrennt über andere Taster zu steuern.

Settings

Settings contains the configuration for general settings that are valid for all shading element. Navigate to “all apps – settings – blinds”.

Mode
Short button press – completely up: If the blinds button is pressed for a short period of time, then the blinds will travel in the desired direction until either the blinds are fully open/closed, or a further press of the button causes them to stop where they are. A long button press sets the angle for the slats, i.e. after a wait time to correctly identify a long button press, the blind slats begin to turn until the button is released.

Short button press - set slats: A short button press changes the angle of the blinds and a long button press completely opens or closes the jalousie. A second button press interrupts the travel and the jalousie stops where it is.

Over-travel time
The over-travel time lets you define the percent of time to increase the time that the jalousie takes for completely UP to completely DOWN. This makes sure that the blinds are really open or closed.

Activate wind lock
If you have activated this option, then all shading elements are closed if it is windy. If you want to exempt elements from this wind lock, it can be done for each individual element.

Close at twilight
If “close at twilight” is selected, then all blinds will close as soon as twilight is detected. If you do not want all blinds to close at twilight, then deactivate “close at twilight” for each individual blind. In addition, you can also delay the closing at twilight by entering the number of minutes you wish to wait after twilight until the blinds close.

Shading Control

shading control let automatically control your blinds based on the sun. Now you have always enough brightness, without dazzling yourself. You can decide on yourself, how much light you want.

In summer, your blinds can close automatically at high outside temperatures while you can use the energy of the sun in winter. Of course you have the possibility to control your blinds via app or switch as usual.

You can find shading control under „settings“ - „shadingcontrol“.

Create

To use the shading control, you have to add facades. A facade is an own control unit with controls its assigned blinds by cardinal directions.

You can add as many facades as you want under „settings“ - „shading control“. Preferably you add as many facades as outside walls you have. Usually there are 4 facades, which are configured with north, east, south, west or if the building is arranged diagonally the sun with northeast, southeast, southwest, northwest.

In the parameter panel of the facade, the direction can be set. Choose the best fitting of the 8 available directions. Assign your facade a name to order it easier later.

In addition to the direction you can choose a type. You can always add only blinds of the same type.

Configuration

To control your blinds automatically you have to assign them to a facade. you can do that in the parameter panel of an existing facade under „elements“.

ATTENTION! Blinds should not be assigned to several facades. Take care of blind groups too.

If you also want to use the shading control to use heat of the sun, you can add the inside temperature under „thermostats“. You can also leave this area empty, if you do not want to enable heat using.

On the bottom of the parameter panel you can see a table with control positions. This table is the base of the shading control. You can set blind positions to a specific sun height and also the angle at jalousies.

With the „submit“ button you can accept the set values to the facade. You can also set the values to all facades or reset it to default values.

On the bottom of the parameter panel you can set additional parameter. The minimal brightness must be above to control the blinds by the table. Among this value the blinds keeps open.

If the heat protection is active, all blinds will close completely, if the outside temperature is above the setting.

On using a thermostat and heat using is active, all blinds will open completely, if the outside temperature and inside temperature is among the setting.

Control

The shading control helps you to reduce manual interactions with blinds. After the configuration of the shading control no more manual control is needed anymore. Anyhow you have always the possibility to deactivate or activate the control or to monitor it.

The static panel of the shading control provides summary information of the control. Values like sun height and lighted facades are listed.

Beside this, you can disable or enable the whole control with one click. The function „reactivate automatically“ activates facades at a specific time, if they were deactivate by manual interaction for example. If you want to exclude a facade from this function, you can do this with „lock facade“ in the parameter panel of a facade.

The Object Panel shows the configured direction. The icon is colored orange, if the facade is lighted by the sun. On the right side the current blind state is shown. If the facade is disabled, the whole panel is greyed out.

The operator panel of a facade provides its main information. Sun height, light state and outside brightness from your weather station are some of listet values.

Assigned blinds are listet too.

On the bottom side of the operator panel the control table is listet. The line with the current sun height is marked. If the facade is active, lighted and the min brightness is reached, the marker gets orange and the position of this line will be controlled . If heat using or heat protection is active, they have priority.

Scenes

Shading control provides following functions within scenes (then ...):

  • Activate all: All facades will be activated, except locked ones.
  • Activate facade: Facade will be activated, except it is locked.
  • Deactivate facade: Facade will be deactivated.

Logik

Das Beschattungsregelung bietet folgende Möglichkeiten für die Verwendung in Logiken:

  • Aktiv: Hiermit kann der Status der Beschattungsregelung ausgelesen und gesetzt werden

Irrigation

The irrigation app offers the possibility to automatically water the garden with valves, pumps and taking into account selected factors, such as soil moisture.

The Irrigation App can be found under "All Apps" - "Irrigation".

Configuration

Click on "Add" to set up the irrigation.
In the pop-up that appears, the user is guided through the steps of the initial configuration. If you do not want to make a decision on certain settings yet, you can click on "Next" to skip them and make a decision later.

valves
All valves available in the system can be added to the irrigation. For each valve there is the possibility to set a desired watering duration.

pump
A pump can also be selected as an option.

rain sensor
If a weather station or a rain sensor is configured in the system, it is possible to pause the irrigation due to recent rain. To do this, the maximum number of rain-free days must be determined.

soil moisture
If a soil moisture sensor is connected, the irrigation can be paused if there is enough moisture to prevent overwatering.

weekly schedule
To water the garden automatically, different start times can be set for each day of the week.

annual planning
Finally, the irrigation can be deactivated for a desired period of time.

Care must be taken that the irrigation is automatically deactivated by the weather station, soil moisture and annual planning. As a result, the automatic watering schedule is not executed. Manual starting is still possible.

Operation

Clicking on "Start" starts the irrigation with all the set valves and their opening time as well as the optional pump.

Attention! This will overwrite the inactive status.

Clicking on "Stop" closes all valves and stops the optionally selected pump.

Scenes

The Irrigation App offers the following triggers for scenes (if ...):

  • Irrigation started: Irrigation has been started.
  • Irrigation stopped: Irrigation has been stopped

The Irrigation App offers the following functions for scenes (then ...):

  • Start (optional: force start): Start watering. Optionally start inactive watering.
  • Stop: Stop watering.
  • Lock: Lock irrigation
  • Unlock: Unlock irrigation

Logic

The irrigation offers the following possibilities for system logics:

  • Inactive (read only): Applies when irrigation has been set inactive by the weather station, soil moisture or annual planning.
  • Irrigation in progress (read only): Applies if irrigation is currently running.
  • Irrigation active (write only): Irrigation is started or stopped.
  • Lock: Irrigation locked

Systemmeldungen

Folgende Systemmeldungen können von der Bewässerung ausgelöst werden:

Inaktiv durch Ausreichend Bodenfeuchte

Dieser Status sagt aus, dass die aktuelle Bodenfeuchte über dem unter Bodenfeuchte eingestellten Wert liegt.

Dieser Status wird sofort erkannt.

In diesem Zustand werden die Betriebszeiten ignoriert und die Bewässerung startet nicht.

Im Object Panel wird ein kurzer Hinweis sowie ein Schlaf-Icon angezeigt.
Im Operator Panel wird ein längerer Hinweis sowie ein Schlaf-Icon angezeigt.

Inaktiv durch Jahresplanung

Dieser Status sagt aus, dass das heutige Datum außerhalb des unter Jahresplanung eingestellten Bereichs liegt.

Dieser Status wird sofort erkannt.

In diesem Zustand werden die Betriebszeiten ignoriert und die Bewässerung startet nicht.

Im Object Panel wird ein kurzer Hinweis sowie ein Schlaf-Icon angezeigt.
Im Operator Panel wird ein längerer Hinweis sowie ein Schlaf-Icon angezeigt.

Inaktiv durch Anzahl an regenfreien Tagen nicht erreicht

Dieser Status sagt aus, dass die Anzahl an regenfreien Tagen unter dem unter Regensensor eingestellten Wert liegt.

Dieser Status wird sofort erkannt.

In diesem Zustand werden die Betriebszeiten ignoriert und die Bewässerung startet nicht.

Im Object Panel wird ein kurzer Hinweis sowie ein Schlaf-Icon angezeigt.
Im Operator Panel wird ein längerer Hinweis sowie ein Schlaf-Icon angezeigt.

Motion Detector

A motion detector can be connected to a light module or a digital module. The motion detector has a pre-defined function when connected to a light module. Motion detectors can be simulated in the system for test purposes.

You can find motion detectors under “all apps” –“motion detectors”.

Erstellen

Mit einem Klick auf „Bewegungsmelder hinzufügen“ wird ein universeller Bewegungsmelder hinzugefügt.

Configuration

Naming
If you have connected a motion detector to a light module, then it is automatically assigned the same name as the light. If you wish to assign a different name, then deactivate the option “same name as light” in the parameter panel and enter the name you wish. If the motion detector is connected to a digital module, then you must assign it a name yourself.

Invert
If the motion detector is connected to a digital module, you have the possibility to invert the logic by activating the option “invert” in the operator panel.

Reserve
Should you have a motion detector in the system that you do not use, you can hide in from the app “motion detector” by activating the option “reserve (hide in display)” in the parameter panel. To unhide it, you will find your movement detector in the app “hardware”.

Mode
If you wish to change the mode, i.e. convert the motion detector input to a switch or a digital input, you can do this by changing the mode for the motion detector in the parameter panel. Not all modes can be changed in all modules, or not all possibilities are available. This means that a motion detector for a light module can only be changed into a button. All three modes are available for motion detectors for a digital module.

Simulation

For example, if you have linked a motion detector to a scene and you would like to test this scene, then you do not have to go to the motion detector and activate it every time, you can change the state using simulation. Simply activate the option “simulation on” in the operator panel to see the option with which you can change the state.

Warning, if you leave the simulation switched on, the autonomous function will not work!

Scenes

You can also use the motion detector for a scene (in as far as it has been named). In the scene, select the motion detector for “if …” and decide if you want the scene to be carried out on the rising or falling edge of the signal.

Rising edge
The electrical contact of the motion detector has been activated.
Falling edge
The electrical contact of the motion detector has been deactivated (after the internal time of the motion detector).

Logik

Der Bewegungsmelder bietet folgende Möglichkeiten für System Logiken:

  • Helligkeit [Lux]: Helligkeit in Lux (lesen, nur bei Universalbewegungsmeldern)

Daikin

Via the Daikin app, compatible Daikin air conditioners can be integrated into the system, controlled via the visualisation and linked to other functions via scenes.

You can find the application under 'Settings' - 'Daikin'.

Daikin Cloud

Login

Air conditioners connected to the ONECTA account can be found via the Daikin panel

If no account is connected yet, you will be asked to log in.

Bedienung

Once the Daikin air conditioner has been successfully integrated into the system, several controls are available.

The temperature, operating state, and operating mode can be adjusted.

The ventilation mode can also be changed from "Automatic" to "Manual" or "Silent" (if supported by the Daikin unit). In manual mode, the fan speed can be adjusted.
In addition, the airflow direction can be configured.

All settings can also be controlled via scenes. For example, the ventilation level or temperature can be changed as soon as the defined "if ..." conditions are met.

Szenen

The Daikin App provides the following triggers for scenes (if ...):

  • Switched Off: The air conditioner was switched off via the system
  • Switched On: The air conditioner was switched on via the system

The Daikin App offers the following functions for scenes (then ...):

  • Switch off: The air conditioner is switched off
  • Set operating mode: A freely selectable operating mode (heating, cooling,...) is sent as a default to the unit
  • Switch on: The air conditioner is switched on
  • Set horizontal airflow direction: A freely selectable airflow direction is sent as a default to the unit
  • Set ventilation stage: A freely selectable ventilation level is sent to the unit as default
  • Set ventilation mode: A freely selectable ventilation mode is sent as a default to the unit
  • Start with options: The air conditioner is switched on with various freely selectable parameters
  • Should set temperature: A freely selectable setpoint temperature is sent to the unit
  • Set vertical airflow direction: A freely selectable airflow direction is sent as a default to the unit

It should be noted that not every type of unit provides all functions.

Denon

This section contains information on using connected DENON devices.

Denon lets you play music throughout your house, whether from a USB stick, music server, Internet radio, iPod, AUX or online music.

The Denon app is located under “all apps” -“Denon”.

Currently, only the DENON DRA-N4 amplifier is supported by the system.

Operation

Volume
You can change the volume via the “+” and “-“ buttons, or use the slider.

Source
Use this to determine where your music is to come from and see the Denon display below it. Navigate around your Denon using the 4 arrows and the enter button.

Favourites
Add the current programme to your favourites list using the button “add to favourites” so that you can find it again quickly. All your favourites are displayed in a list below this.

ON/OFF
Switch your Denon on an off.

Status
Shows which music source is currently active, Internet music, iPod etc. and shows the current IP address.

In the parameter panel, you can also define whether this Denon is to be switched with the universal scenes or not “remove from universal scene”) and how loud the Denon can be allowed to be.

Szenen

Die Denon App bietet folgende Auslöser für Szenen (wenn ...):

  • Play: Die Wiedergabe wurde mit Play gestartet
  • Pause: Das Wiedergabe wurde mit Pause gestoppt

Die Denon App bietet folgende Funktionen für Szenen (dann ...):

  • Ausschalten: Das Gerät wird ausgeschaltet
  • Einschalten: Das Gerät wird eingeschaltet
  • Play: Die aktuelle Wiedergabe wird gestartet

Digital Output

The app “digital outputs” provides you with an overview of all digital outputs in your system. This is where you can name them and change the state of the outputs.

The app “digital outputs” is located under “all apps” – “digital outputs”.

You have two possibilities to change the state of a digital output. Either you can click on the power symbol on the left in the object panel or you can click on the button “switch” in the operator panel.

Configuration

You can give a name to a digital output in the parameter panel and optionally allocate it to a room.

Save output if bus fault
If the output is active when the bus connection to the CPU fails (for example if the 24V power supply to the module fails), this option lets you guarantee that the active remains activated even in a fail state. If this option is not activated, then the output is reset after every bus connection failure.

In safety-critical controllers, it should be carefully examined whether this function should be activated, since this output is kept active if the system fails.

Mode
With the mode setting, you can change the behavior of the output once it is active. The following options exist:

  • Standard
    This ist the normal setting for a digital output. With this, the output stays active until the signal ends.

  • Minimum on duration
    With this mode, the output stays active for at least the specified time, even when it is deactivated before.

  • Pulse
    In this mode, the output will automatically be deactivated after the defined timeframe.

Reserve (hide in visualization)
If you have a digital output in your system that you do not use, then you can hide this digital output in the digital output app by activating the option “reserve (hide in visualization)” (located in the parameter panel). (To unhide, the digital output can be found in the hardware app).

Change mode
If you wish to change the mode, i.e. convert a digital output to a socket, then you can do this by changing the mode for the digital output in the parameter panel.

Scenes

You can also use a digital output for a scene (in as far as it has been named). In the scene’s “if …” simply select the digital output to see the following possibilities:

Switch off
The digital output is switched off.

Switch on
The digital output is switched on.

switch on for
The digital output will be switched on for a defined amount of time.

Toggle
The state of the digital output is toggled.

Digital Input

A digital input can be used for functions for which no dedicated Smart Building Automation function module is available. Each digital input can be named and simulated for testing purposes.

You can find the app “digital inputs” under “all apps” – “digital inputs”.

Configuration

Reserve
If you have a digital input in your system that you are not using, you can activate the option “reserve (hide in visualization) to hide this digital input in the app “digital inputs”. (To unhide this, the digital input can be found in the hardware app)

Mode
If you wish to change the mode, i.e. convert a digital input into a button or a movement detector, this can be done in the parameter panel for the digital input under “mode”.

Simulation

If you have connected a digital input to a scene and would like to test the scene, you do not have to navigate to the digital input and activate it every time, you can change it directly via simulation. To do this, activate “simulation on” in the operator panel to see the option “simulation value” with which you can change the state. Warning, once the simulation has been activated, the autonomous function will no longer work! Any changes in the state of the input “hardware” will be overwritten by the simulation.

Scenes

You can also use a digital input for a scene (in as far as it has been named). Select the digital input in the scene’s “IF ….” and decide whether you want the scene to be carried out on the rising or falling edge.

Rising edge
The electrical contact of the digital input has been closed.

Falling edge
The electrical contact of the digital input has been opened.

EEBus

Mit der EEBus-App, können Sie Geräte einbinden, welche von dem System unterstützt werden. Diese App finden Sie unter „Einstellungen“ - „EEBus“.

Konfiguration

Um Geräte wie Vaillant einzubinden muss das Protokoll EEBus aktiviert werden. Das kann in den Einstellungen unter „EEBus“ mit dem Button „Starten“ aktiviert werden.
Danach wird der SKI (Subject Key Identifier) angezeigt, dieser muss dann beim Hinzufügen der Verbindung in der App des jeweiligen Gerätes zusammenstimmen.

Unter „Verfügbare Geräte“ werden alle EEBus Geräte angezeigt, welche im Netzwerk gefunden wurden. Wenn ein Gerät verbunden werden soll muss dieses angeklickt werden und im Popup bestätigt werden. Danach erscheint es unter „Vertraute Geräte“, hier kann es auch wieder entfernt werden, wenn die Verbindung getrennt werden soll.

Energiemanagement

Mit der Energiemanagement-App wird die Möglichkeit bereitgestellt, den Energiefluss des Hauses im Smart Building Automation System darzustellen.

Die Energiemanagement-App ist unter Alle AppsEnergiemanagement zu finden.

Ladestationen können im Energiemanagement nur unter bestimmten Voraussetzungen verwendet werden. Mehr dazu unter Ladestation-Verlinkungen

Erstellen

Durch einen Klick auf Hinzufügen wird ein Wizard gestartet.

Falls bereits ein Energiemanagement vorhanden ist, kann ein neues Energiemanagement erstellt oder zusätzliche Panels hinzugefügt werden. Andernfalls wird dieser Schritt übersprungen.

Nun ist ein Fenster geöffnet, in welchem alle verschiedenen Komponenten konfiguriert werden können:

  • Stromtarif: Hier kann ein Stromtarif verbunden werden, der für eine Spotpreis-Regelung verwendet werden kann. Mittels dieser Regelung werden die ausgewählten Verbraucher dann zu dem Tageszeitpunkt gestartet, an welchem der Strompreis am günstigsten ist.
  • Netzbezug: Hier kann ein Gerät verknüpft werden, welches den aktuellen Netzbezug bzw. die aktuelle Netzeinspeisung abbildet.
  • Erzeuger: Hier können beliebig viele Erzeuger verknüpft werden.
  • Batterie: Hier können beliebig viele Batterien verknüpft werden.
  • Verbraucher: Hier können beliebig viele Verbraucher verknüpft werden.

Wenn unter Stromtarif auf Hinzufügen geklickt wurde, wird ein Fenster geöffnet, in welchem alle Stromtarife ausgewählt werden können.

Wenn unter Netzbezug auf Hinzufügen geklickt wurde, wird ein Fenster geöffnet, in welchem ein Smart Meter ausgewählt werden kann.
Wenn stattdessen ein anderer Wert aus dem System für den Netzbezug verwendet werden soll (z.B. ein Rest-, Modbus-, Logik-Wert oder ein Wert aus einer anderen App), dann links unten auf + manuellen Netzbezug erstellen klicken.

Wenn der Netzbezug manuell konfiguriert werden soll, sind folgende Einstellungen vorzunehmen:

  • Aktuelle Leistung und Einheit: Der Wert für die aktuelle Leistung sowie die passende Einheit sind festzulegen.
  • Bedeutung eines negativen Werts: Die Bedeutung negativer Werte ist zu definieren (Netzeinspeisung oder Netzbezug).
  • Angezeigtes Symbol: Ein Symbol zur Anzeige ist auszuwählen.
  • Trendfarbe: Die Trendfarbe für das Gerät ist zu bestimmen.

Wenn unter Erzeuger auf Hinzufügen geklickt wurde, wird ein Fenster geöffnet, in welchem alle Fronius Wechselrichter ausgewählt werden können.
Wenn stattdessen der Erzeuger aus anderen Werten konfiguriert werden soll (z.B. Rest-, Modbus-, Logik-Werten oder Werten aus einer anderen App), dann links unten auf + manuellen Erzeuger erstellen klicken.

Wenn der Erzeuger manuell konfiguriert werden soll, sind die folgenden Einstellungen vorzunehmen:

  • Angezeigter Name: Es ist ein Name einzugeben, der angezeigt werden soll.
  • Aktuelle Leistung und Einheit: Der Wert, der die aktuelle Leistung darstellt, sowie die entsprechende Einheit sind festzulegen.
  • Leistungsmaximum und Einheit: Das maximale Leistungsniveau sowie die entsprechende Einheit sind zu bestimmen.
  • Angezeigtes Symbol: Ein Symbol, das angezeigt werden soll, ist auszuwählen.
  • Trendfarbe: Die Farbe, die im Trend für dieses Gerät verwendet werden soll, ist zu bestimmen.

Wenn unter Batterie auf Hinzufügen geklickt wurde, wird ein Fenster geöffnet, in welchem alle Fronius Batterien ausgewählt werden können.
Wenn stattdessen die Batterie aus anderen Werten konfiguriert werden soll (z.B. Rest-, Modbus-, Logik-Werten oder Werte aus einer anderen App), dann links unten auf + manuelle Batterie erstellen klicken.

Wenn die Batterie manuell konfiguriert werden soll, sind folgende Einstellungen vorzunehmen:

  • Angezeigter Name: Ein anzuzeigender Name ist einzugeben.
  • Aktuelle Leistung und Einheit: Der Wert für die aktuelle Leistung sowie die passende Einheit sind festzulegen.
  • Bedeutung eines negativen Werts: Die Bedeutung ist festzulegen.
  • Aktuelle Kapazität und Einheit: Der aktuelle Kapazitätswert samt Einheit ist anzugeben.
  • Maximale Kapazität: Die maximale Kapazität (in kWh) ist zu bestimmen.
  • Trendfarbe: Die Trendfarbe für das Gerät ist auszuwählen.

Wenn unter Verbraucher auf Hinzufügen geklickt wurde, wird ein Fenster geöffnet, in welchem folgende Geräte hinzugefügt werden können:

  • Analog Ausgänge
  • Digital Ausgänge
  • Smart Meter
  • Ladestationen
  • MyPV Geräte
  • HomeConnect Geschirrspüler
  • HomeConnect Waschmaschinen
  • HomeConnect Trockner

Wenn stattdessen der Verbraucher aus anderen Werten konfiguriert werden soll (z.B. Rest-, Modbus-, Logik-Werten oder Werte aus einer anderen App), dann links unten auf + manuellen Verbraucher erstellen klicken.

Wenn das Gerät manuell konfiguriert werden soll, sind die folgenden Einstellungen vorzunehmen:

  • Angezeigter Name: Ein anzuzeigender Name ist einzugeben.
  • Angezeigtes Symbol: Ein Symbol zur Anzeige ist auszuwählen.
  • Trendfarbe: Die Farbe für die Trendanzeige ist zu bestimmen.
  • Typ des Verbrauchers: Der Typ des Verbrauchers ist auszuwählen. Starre Leistungsvorgabe bedeutet, dass der Verbraucher zwischen Ein/Aus geschaltet werden kann. Stufenlose Leistungsvorgabe ermöglicht eine Regelung zwischen zwei Werten. Visualisierung zeigt nur Werte an, ohne dass ein Start möglich ist.

Wenn der Typ Starre Leistungsvorgabe gewählt wurde, sind folgende Einstellungen vorzunehmen:

  • Gerät starten: Es ist auszuwählen, wie das Gerät gestartet wird.
  • Gerät stoppen: Es ist auszuwählen, wie das Gerät gestoppt wird.

Wenn der Typ Visualisierung gewählt wurde, sind folgende Einstellungen vorzunehmen:

  • Aktuelle Leistung und Einheit: Der Wert für die aktuelle Leistung sowie die passende Einheit sind festzulegen.
  • Bedeutung eines negativen Werts: Es ist festzulegen, was ein negativer Wert bedeutet. Bei Netzeinspeisung wird angegeben, dass Energie eingespeist wird. Bei Netzbezug wird angezeigt, dass Energie bezogen wird.

Bei dem Typ Visualisierung kann danach mit einem Klick auf Fertig der Verbraucher hinzugefügt werden. Für die anderen beiden Typen wird mit einem Klick auf Weiter die nächste Seite der Konfiguration geöffnet.

Wenn der Typ Starre Leistungsvorgabe gewählt wurde, sind in diesem Schritt folgende Einstellungen vorzunehmen:

  • Benötigter Überschuss und Einheit: Der Energieüberschuss, der zum Start des Geräts erforderlich ist, sowie die Einheit sind festzulegen.
  • Eigenverbrauchsregelung: Wenn diese Option aktiviert ist, wird das Gerät gestartet, sobald der definierte Energieüberschuss vorhanden ist.
  • Spotpreis-Regelung (nur aktivierbar, wenn ein Stromtarif verknüpft ist): Wenn diese Option aktiviert ist, wird das Gerät gestartet, sobald der günstigste Tageszeitpunkt für den Start des Geräts erreicht ist.
  • Einschaltdauer: Wenn die Option Spotpreis-Regelung aktiviert ist, muss zudem die Dauer angegeben werden, für welche der Verbraucher eingeschaltet sein soll.

Wenn weitere Spezialfunktionen für den Verbraucher genutzt werden sollen, auf Experteneinstellungen klicken, ansonsten kann der Verbraucher mit einem Klick auf Fertig hinzugefügt werden.

Wenn der Typ Stufenlose Leistungsvorgabe gewählt wurde, sind folgende Einstellungen vorzunehmen:

  • Leistung über Stellgröße skalieren: Falls der Leistungswert direkt auf ein Property des Verbrauchers geschrieben werden kann, kann diese Option deaktiviert bleiben. Ansonsten ist diese Option zu aktivieren und die Werte für minimale und maximale Stellgröße sind festzulegen.
  • Minimale und Maximale Stellgröße: Diese Werte sind nur sichtbar, wenn die Option Leistung über Stellgröße skalieren aktiviert ist. In diesem Bereich werden die Werte dann auf Stellgrößenvorgabe geschrieben.
  • Minimum und Maximum [W]: Die minimale und maximale Leistung, welche dieses Gerät verwenden soll.
  • Leistungsvorgabe/Stellgrößenvorgabe: Hier ist das Property auszuwählen, auf welches die Leistung oder die Stellgröße geschrieben werden soll. Wenn die Option Leistung über Stellgröße skalieren deaktiviert ist, muss zusätzlich die Einheit definiert werden.
  • Eigenverbrauchsregelung: Wenn diese Option aktiviert ist, wird das Gerät gestartet, sobald der definierte Energieüberschuss vorhanden ist.
  • Spotpreis-Regelung (nur aktivierbar, wenn ein Stromtarif verknüpft ist): Wenn diese Option aktiviert ist, wird das Gerät gestartet, sobald der günstigste Tageszeitpunkt für den Start des Geräts erreicht ist.
  • Einschaltdauer: Wenn die Option Spotpreis-Regelung aktiviert ist, muss zudem die Dauer angegeben werden, für welche der Verbraucher eingeschalten sein soll.
  • Einschaltleistung und Einheit: Wenn die Option Spotpreis-Regelung aktiviert ist, muss die Leistung, mit welcher der Verbraucher bei der Spotpreis-Regelung eingeschalten werden soll sowie die entsprechende Leistung, definiert werden.

Wenn weitere Spezialfunktionen für den Verbraucher genutzt werden sollen, auf Experteneinstellungen klicken, ansonsten kann der Verbraucher mit einem Klick auf Fertig hinzugefügt werden.

Zusätzlich zu den zuvor vorgenommenen Einstellungen können auch folgende Experteneinstellungen definiert werden:

  • Zeitplan
  • Betriebsverhalten
  • Zusätzliche Verknüpfungen
  • Zwangsstart/-stopp
  • Reaktivierung
  • Manuelle Bedienung

Zeitplan:
Wird Zeitplan verwenden aktiviert, wird das Gerät täglich zu einem festgelegten Zeitpunkt für eine bestimmte Dauer eingeschaltet. In diesem Fall sind folgende Einstellungen erforderlich:

  • Programmdauer: Die tägliche Mindestlaufzeit ist auszuwählen.
  • Spätestes Programmende: Das späteste Programmende des Geräts ist auszuwählen.

Wenn zum Beispiel für die Programmdauer 1 Stunde und für das späteste Programmende 16:00 Uhr ausgewählt wird, wird das Gerät um 15 Uhr gestartet.
Dafür müssen jedoch folgende zusätzliche Faktoren zutreffen:

  1. Die Startfreigabe des Geräts muss vorhanden sein (nur bei Verbrauchern die NICHT manuell konfiguriert wurden)
  2. Falls Bedingungen für die zusätzliche Startfreigabe definiert sind, müssen diese zutreffen
  3. Falls Bedingungen für den Zwangsstart definiert sind, dürfen diese nicht zutreffen
  4. Falls Bedingungen für den Zwangsstopp definiert sind, dürfen diese nicht zutreffen

Falls diese Faktoren erst nach dem geplanten Start, aber noch vor dem geplanten Programmende (z.B. um 15:15 Uhr) erfüllt sind, wird das Gerät gestartet.

Falls sie jedoch erst nach dem geplanten Programmende (z.B. nach 16:00 Uhr) erfüllt sind, wird das Gerät durch den Zeitplan erst wieder am nächsten Tag um 15 Uhr gestartet (falls dann wiederum die Faktoren zutreffen).

Betriebsverhalten:

  • Einschaltverzögerung: Hier kann die zu wartende Zeit bis zum Gerätestart bei vorhandenem Überschuss angegeben werden. Wird der Überschuss in dieser Zeit unterschritten, erfolgt kein Start.
  • Mindest-Einschaltdauer: Hier kann die minimale Einschaltdauer bestimmt werden. Nach Ablauf wird das Gerät nur gestoppt, wenn der Überschuss nicht mehr vorhanden ist.

Zusätzliche Verknüpfungen:

  • Zusätzliche Startfreigabe: Ein zusätzlicher Freigabewert kann eingetragen werden. Wenn dieser eingetragen wurde, kann der Verbraucher erst gestartet werden, sobald dieser Wert zutrifft.
  • Gerätestatus: Ein Wert für den Status kann hinzugefügt werden.
  • Aktuelle Leistung: Hier kann die aktuelle Leistung und die zugehörige Einheit definiert werden.

Zwangsstart/-stopp:

  • Zwangsstart: Hier können die Bedingungen für einen Start unabhängig vom Gerätestatus oder Energieüberschuss festgelegt werden.
  • Zwangsstopp: Hier können die Bedingungen für einen Stopp unabhängig vom Gerätestatus oder Energieüberschuss festgelegt werden.

Ein Zwangsstart oder -stopp wird nur unter bestimmten Bedingungen ausgeführt:

  • Das Gerät wurde nicht manuell deaktiviert oder per Sperr-Icon deaktiviert.
  • Die Zwangsbedingung trifft seit der letzten Aktivierung ununterbrochen zu.
  • Zwangsstart: Nur wenn kein Zwangsstopp gleichzeitig zutrifft.
  • Zwangsstopp: Nur wenn kein Zwangsstart gleichzeitig zutrifft.

Reaktivierung:

  • Automatisch reaktivieren: Wenn diese Option aktiviert ist, wird der Verbraucher - falls dessen Regelung deaktiviert ist - zu einem bestimmten Zeitpunkt automatisch reaktiviert.

Manuelle Bedienung:

  • Leistungsänderungen ignorieren: Wenn diese Option aktiviert ist, werden Leistungsänderungen von außen, während das Gerät durch das Energiemanagement gestartet wurde, ignoriert.

Spotpreis-Regelung (nur sichtbar wenn ein Stromtarif ausgewählt ist und die Spotpreis-Regelung des Geräts aktiviert ist):

  • Bereits gelaufene Zeit von Spotpreis-Laufzeit abziehen: Wenn diese Option aktiviert ist, wird die bereits gelaufene Zeit des Geräts, von der Einschaltdauer der Spotpreis-Regelung abgezogen. Wenn das Gerät jeden Tag, unabhängig von vorherigen Starts, für die eingestellte Einschaltdauer laufen soll, dann ist diese Option zu deaktivieren.

Wenn in der Geräteübersicht auf Weiter geklickt wird, wird abschließend eine Seite zur Bestätigung der Konfiguration angezeigt. Durch einen Klick auf Fertig wird der Wizard geschlossen und das Energiemanagement erstellt.

Bedienung

Die Energieflüsse werden – abhängig von der Bildschirmgröße des Geräts – in verschiedenen Größen dargestellt. Im Mindestumfang des Panels wird Folgendes angezeigt:

  • Wie viel Leistung aktuell vom Netz bezogen oder eingespeist wird
  • Wie viel Leistung aktuell erzeugt wird
  • Wie viel Leistung aktuell verbraucht wird
  • Wie viel Leistung in die Batterien gespeichert oder aus diesen entnommen wird sowie der Gesamtspeicherstand der Batterien in Prozent

Im großen Panel sind die einzelnen Geräte ersichtlich. Dabei wird die aktuelle Leistung angezeigt, bei den Batterien zusätzlich der Speicherstand in Prozent.

  • Energieerzeuger und Batterien: Es werden maximal drei Geräte angezeigt. Wenn mehr als drei Geräte vorhanden sind, wird beim letzten Gerät die Leistung der übrigen Geräte zusammengefasst angezeigt.
  • Verbraucher: Es werden maximal vier Geräte dargestellt. Die Leistung der übrigen, nicht hinzugefügten Geräte wird unter Andere zusammengefasst dargestellt.

Bedeutung der Icons über den Verbrauchern:

  • Durchgestrichener Kreis: Das Gerät wurde durch erfüllte Bedingungen zwangsgestartet oder -gestoppt.
  • Hand im Kreis: Das Gerät wurde durch eine manuelle Bedienung deaktiviert und ist somit von der Regelung ausgenommen.
  • Schloss im Kreis: Das Gerät wurde im Parameter Panel deaktiviert und ist daher von der Regelung ausgenommen oder kann nicht gestartet werden.

Im Operator Panel werden folgende Daten angezeigt:

  • Der Status des Energiemanagements
  • Der aktuelle Netzbezug oder -überschuss
  • Die einzelnen Geräte

Verbraucher:

  • Pro Gerät ist ein Panel sichtbar, welches das Icon, den Namen sowie den Gerätestatus anzeigt
  • Weitere Informationen über den Status und die Bedienung sind darunter sichtbar
  • Für erweiterte Bedienungen kann das Panel mit einem Pfeil rechts unten aufgeklappt werden
  • Geräteregelung aktiv: Hier kann die Regelung des Geräts de-/aktiviert werden. Wenn das Gerät durch eine manuelle Bedienung deaktiviert wurde, wird diese Einstellung ignoriert.
  • Steuerung reaktivieren: Falls das Gerät durch eine manuelle Bedienung deaktiviert wurde, kann die Steuerung hierüber wieder aktiviert werden.

Erzeuger:

  • Pro Gerät ist ein Panel sichtbar, welches das Icon und den Namen anzeigt
  • Zudem wird die aktuelle Leistung sowie das Leistungsmaximum angezeigt

Batterien:

  • Pro Gerät ist ein Panel sichtbar, welches das Icon und den Namen anzeigt
  • Zudem wird die aktuelle Leistung, aktuelle Kapazität sowie die maximale Kapazität angezeigt

Netz:

  • Wenn konfiguriert, wird ein Panel angezeigt, welches das Icon und den Namen anzeigt
  • Zudem wird die aktuelle Leistung angezeigt

Verlauf:
In diesem Bereich kann die Regelung des Energiemanagements nachvollzogen werden. Zusätzlich können verschiedene Filter angewendet werden.

Trend:
In diesem Abschnitt wird der Energiefluss des Energiemanagements über verschiedene Zeiträume dargestellt.

Spotpreis-Zeitplan:
Dieser Abschnitt ist nur eingeblendet, wenn ein Stromtarif verknüpft ist und mindestens ein Verbraucher die Spotpreis-Regelung aktiviert hat. Wenn das der Fall ist, wird hier ein Zeitplan angezeigt, wann ein Verbraucher durch den Spotpreis gestartet wird oder wurde.

Im Parameter Panel können wie gewohnt der Name sowie der zugehörige Bereich des Energiemanagements geändert werden.

Zusätzlich können folgende Einstellungen vorgenommen werden:

  • Energiemanagement aktiviert: Es wird festgelegt, ob das Energiemanagement zur Steuerung von Geräten oder nur zur Anzeige verwendet wird.
  • Automatisch reaktivieren: Wenn aktiviert, kann eine Uhrzeit definiert werden, zu der das Energiemanagement täglich wieder aktiviert wird – sofern es durch Szenen, Logiken oder manuell im Parameter Panel deaktiviert wurde. Mit einem Klick auf Für alle Verbraucher übernehmen kann diese Zeit auf alle Verbraucher angewendet werden, bei denen diese Option bereits im Wizard aktiviert wurde.
  • Mindest-Restüberschuss [W]: Es wird definiert, wie viel Überschuss nach dem Start eines Geräts mindestens vorhanden sein muss. Dadurch wird verhindert, dass Geräte durch kleine Schwankungen sofort wieder Energie aus dem Netz beziehen müssen.
  • Laden der Batterie priorisieren: Wenn aktiviert, wird das Laden der Batterien bis zu einem definierten Ladestand gegenüber dem Start von Verbrauchern priorisiert. Wenn deaktiviert, werden Verbraucher wie gewohnt priorisiert gestartet.

Stromtarif:
Es kann ein Stromtarif hinzugefügt werden oder der verwendete Stromtarif gelöscht werden.

Verbraucher:
Für die Verbraucher können folgende Einstellungen vorgenommen werden:

  • Gerät bearbeiten: Durch einen Klick auf das Stift-Icon wird ein Wizard geöffnet, in dem die Einstellungen geändert werden können.
  • Gerät löschen: Durch einen Klick auf das Müll-Icon wird das Gerät gelöscht. Falls dieses Icon nicht angezeigt wird, kann das Stift-Icon verwendet werden, um den Wizard zu öffnen und das Gerät dort durch Löschen und anschließende Bestätigung zu entfernen.
  • Reihenfolge ändern: Wenn mehrere Geräte vorhanden sind, kann durch Halten des Icons mit den drei Strichen die Reihenfolge der Geräte verändert werden. Die hier definierte Reihenfolge wird sowohl im Operator Panel als auch im Object Panel angezeigt.

Beim Klicken auf Hinzufügen können weitere Verbraucher hinzugefügt werden.

Erzeuger:
Für die Erzeuger können folgende Einstellungen vorgenommen werden:

  • Erzeuger simulieren: Wenn aktiviert, werden nicht verfügbare oder noch nicht hinzugefügte Energieerzeuger simuliert. Dabei wird jedoch Energie von nicht erfassten Verbrauchern, die ins Netz einspeisen, ebenfalls als Erzeugung dargestellt.
  • Gerät bearbeiten: Über das Stift-Icon kann der Wizard geöffnet und die Konfiguration geändert werden.
  • Gerät löschen: Über das Müll-Icon kann das Gerät entfernt werden.
  • Reihenfolge ändern: Bei mehreren Geräten kann die Position durch Ziehen des Icons mit den drei Strichen verändert werden. Diese Reihenfolge wird im Operator und Object Panel verwendet.

Beim Klicken auf Hinzufügen können weitere Erzeuger hinzugefügt werden.

Batterien:
Für die Batterien können folgende Einstellungen vorgenommen werden:

  • Gerät bearbeiten: Mit dem Stift-Icon wird ein Wizard geöffnet, um die Konfiguration zu ändern.
  • Gerät löschen: Mit dem Müll-Icon wird das Gerät entfernt.
  • Reihenfolge ändern: Bei mehreren Geräten kann deren Position durch Ziehen verändert werden. Diese Reihenfolge gilt für das Operator und Object Panel.

Beim Klicken auf Hinzufügen können weitere Batterien hinzugefügt werden.

Netz:
Für das Netz stehen folgende Optionen zur Verfügung:

  • Gerät bearbeiten: Über das Stift-Icon kann das Gerät bearbeitet werden.
  • Gerät löschen: Über das Müll-Icon wird das Gerät gelöscht.

Wenn noch kein Gerät für das Netz definiert wurde, kann dieses beim Klicken auf Hinzufügen hinzugefügt werden.

Trend:
In diesem Bereich kann ausgewählt werden, welche Daten im Trend dargestellt werden sollen.

Datenexport:
Es kann festgelegt werden, welche Trenddaten für beliebige Zeiträume exportiert werden sollen.

Erweiterte Parameter:
In diesem Abschnitt können folgende allgemeine Einstellungen angepasst werden:

  • Ausschaltverzögerung: Die Verzögerung beim Stoppen eines Geräts nach Abfall der Leistung wird hier festgelegt.
  • Pause nach Start und Stopp des Geräts: Die Zeitspanne, die zwischen dem Start oder Stopp verschiedener Geräte eingehalten wird.
  • Intervall für dyn. Leistungsanpassung: Das Intervall, in dem die Leistung dynamischer Geräte angepasst wird.

Szenen

Vom Energiemanagement werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Energiemanagement aktivieren: Die Regelung des Energiemanagements wird aktiviert.
  • Energiemanagement deaktivieren: Die Regelung des Energiemanagements wird deaktiviert.
  • Regelung aktivieren für: Die Regelung des Energiemanagements wird für den betreffenden Verbraucher aktiviert.
  • Regelung deaktivieren für: Die Regelung des Energiemanagements wird für den betreffenden Verbraucher deaktiviert.

Logik

Vom Energiemanagement werden folgende Möglichkeiten für System Logiken bereitgestellt:

  • Aktiviert (lesen/schreiben): Es wird dargestellt, ob die Regelung des Energiemanagements aktiviert ist.
  • Be-/Entladung Batterien [kW] (lesen): Der Wert der Be- bzw. Entladung aller Batterien in kW wird bereitgestellt.
  • Einspeisung/Netzbezug [kW] (lesen): Der aktuelle Wert für Einspeisung oder Netzbezug in kW wird ausgegeben.
  • Gesamterzeugung [kW] (lesen): Die gesamte Erzeugungsleistung in kW wird angezeigt.
  • Gesamtverbrauch [kW] (lesen): Der gesamte Verbrauch in kW wird angezeigt.

Grundeinstellungen von verwendeten Geräten

  • Haushaltsgeräte: Siehe HIER
  • Ladestation: Siehe HIER
  • my-PV: Siehe HIER

EnOcean

Mit der App EnOcean Gateway können Geräte, welche den EnOcean-Standard unterstützen, in das System eingebunden werden.

Die EnOcean Gateway App ist unter Einstellungen – EnOcean Gateway zu finden.

Aktuell werden folgende Geräte unterstützt:

  • Bewegungsmelder (Typ: A5-07-01)
  • Heizkörperantrieb (Typ: A5-20-01)
  • Temperaturfühler (Typ: A5-02-05)
  • Luftfeuchtemesser (Typ: A5-10-12)
  • Raumbediengerät (Typ: A5-10-05)
  • Fensterkontakt (Typ: D5-00-01)
  • Funk-Lichtaktor (Typ: F6-02-01)
  • Taster (Typ: F6-02-01)
  • Fenstergriff (Typ: F6-10-00)
  • Digitaler Ausgang (Typ: A5-30-02)

Vorbereitung

Bevor das EnOcean Gateway hinzugefügt werden kann, müssen folgende Schritte durchgeführt werden:

  • Das Gateway muss via Modbus RTU mit dem System verbunden sein.
  • Die Adresse des Gateways auf maximal 14 einstellen. Diese können am Gateway über DIP-Schalter eingestellt werden. Weitere Informationen dazu sind im beiliegenden Datenblatt des Gateways nachzulesen.
  • Die Baudrate, sowie Parität des Gateways nachlesen. Diese können wiederum über die DIP-Schalter ermittelt werden.

Hinzufügen

Durch einen Klick auf Hinzufügen wird ein Wizard geöffnet.

Im ersten Schritt muss die Schnittstelle ausgewählt werden, an welcher das Gateway angeschlossen ist.

Im nächsten Schritt muss die Baudrate sowie die Parität definiert werden.

Nachdem auf Weiter geklickt wurde, wird nach angeschlossenen Gateways gesucht. Die Suche kann ein bis zwei Minuten dauern.
Gefundene Gateways können durch einen Klick auf Hinzufügen, hinzugefügt werden.

Bedienung

Im Operator Panel des Gateways werden alle verbundenen Geräte angezeigt. Wenn von dem bereits eingelernten Gerät noch keine Daten empfangen wurden, wird daneben ein Fragezeichen angezeigt, bis das erste Mal ein Status vom Gerät übertragen wurde.

Mit dem Löschen-Button können bereits eingelernte Geräte wieder gelöscht werden.

Bei einigen Geräten (z.B. Tastern) kann im Operator Panel auch zu den Sub-Geräten navigiert werden. In diesem Fall wird durch einen Klick auf „Taster anzeigen“ ein neues Fenster geöffnet, in dem alle einzelnen Taster angezeigt werden, die im Lernprozess des Gerätes eingelernt wurden.

Bei Tastern, können im Operator Panel auch weitere Sub-Geräte hinzugefügt werden.

Mit dem Button Neu Laden wird die Liste an eingelernten Geräten neu geladen.

Mit dem Button Neues Gerät hinzufügen wird ein Wizard gestartet, der durch den Einlernvorgang neuer Geräte führt.

Unter Zuletzt erhaltene Telegramme werden die letzten empfangenen EnOcean Telegramme angezeigt.

ACHTUNG: Bei Funk-Lichtaktoren kann zwar wie gewohnt die Tageslichtsperre oder die Sperre aktiviert werden, jedoch funktioniert die Autarkfunktion des Lichts immer noch. Dementsprechend kann das Licht trotz aktiver Sperre über den verkabelten Taster geschalten werden.

Im Parameter Panel werden zusätzliche Informationen zum Gateway angezeigt.

Unter Status wird angezeigt, ob das Gateway aktuell verbunden ist und wann zuletzt Daten empfangen wurden. Zusätzlich werden die Firmware und die EnOcean IDs angezeigt.

Unter Einstellungen werden die Einstellungen des Gateways angezeigt.

Mit dem Button Gateway Zurücksetzen wird das Gateway auf Werkseinstellungen zurückgesetzt. Dabei werden alle verbundenen Geräte gelöscht.

Geräte einlernen

Damit die einzelnen Geräte im Smart Building Automation System verwendet werden können, müssen diese zuerst eingelernt werden.

Digitaler Ausgang

Um einen digitalen Ausgang hinzufügen zu können, wird zuvor ein Funkstick und das Programm AirConfig benötigt.

Sobald der Funkstick am PC angeschlossen und das Programm AirConfig gestartet wurde, beginnt die Software automatisch nach dem Funkstick zu suchen. Sobald dieser gefunden wurde, kann auf Commissioning geklickt werden.

Danach auf der linken Seite unter dem Reiter Treiber nach STC-DO suchen, mit der rechten Maustaste auf diesen klicken und Geräte anfragen auswählen. Nun wird nach Geräten gesucht. Wenn ein Gerät gefunden wurde, erscheint dieses unter Geräte. Nachdem auf dieses geklickt wird, öffnet sich ein Fenster in welchem mit Ja bestätigt werden muss, dass die Konfiguration des Gerätes ausgelesen werden soll.

Wird kein Gerät gefunden, ist zunächst zu prüfen, ob der digitale Ausgang mit Strom versorgt wird. Anschließend das Programm neu starten und die Suche nach dem digitalen Ausgang wie oben beschrieben erneut ausführen.

Wenn alles funktioniert hat, wird in der Mitte des Programms die eingestellte Geräte-Konfiguration angezeigt.

Folgende Einstellungen müssen vorgenommen werden:

  • Unter Basis - Anwendung, Licht Steuerung auswählen
  • Unter Basis - Service, bei Sende Ausgang Status den Haken setzen
  • Unter Licht-Steuerung - Tasten Einstellungen, Taste 0 auf Aus und Taste 1 auf An stellen
  • Unter Licht-Steuerung - Einstellungen - Einschalt-Status muss eingestellt werden, ob das Gerät gerade an oder aus ist

Nun im Smart Building Automation System die App EnOcean Gateway und Anschließend das Operator Panel des Gateways öffnen. Dort auf Neues Gerät hinzufügen klicken, danach im Dropdown Digitaler Ausgang (A5-30-02) auswählen und den Einlernvorgang mittels Lern-Knopf starten.

Wenn im System angezeigt wird, dass der Lern-Knopf des Gerätes gedrückt werden soll, blinkt im Programm AirConfig unter Sensor ein neuer Taster auf. Dieser blinkt solange der Einlernvorgang aktiv ist in einem Zyklus von 5 Sekunden. Dieser muss vom Feld Sensoren in das Feld Geräte Konfiguration - Sensoren gezogen werden.

Danach im Reiter Geräte Konfiguration - Basis - Steuerung auf die Schaltfläche LRN klicken. Nun muss dieses Gerät im System gefunden und automatisch hinzugefügt werden. Falls es nicht gefunden wurde, erneut auf LRN klicken.

Abschließend in der App AirConfig auf dem PC mit der rechten Maustaste auf das Gerät klicken und Konfiguration senden auswählen. Sollte dies nicht funktionieren, die Konfiguration neu laden und unter Sensoren prüfen, ob der Taster noch vorhanden ist. Anschließend die Konfiguration erneut senden.

Sollte das Schreiben oder Laden der Konfiguration nicht funktionieren, das Programm AirConfig und den Wizard schließen und den Vorgang erneut von Beginn an durchführen!

Wenn der digitale Eingang bereits im Systen eingebunden wurde, jedoch der Ausgang nicht geschalten werden kann, die folgenden Schritte vornehmen:

  • Das Programm AirConfig öffnen
  • Wie zuvor beschrieben die Konfiguration des STC-DOs laden
  • Zu Sensoren wechseln
  • Falls sich bereits ein Sensor darin befindet, diesen löschen
  • Die Konfiguration des Gerätes schreiben
  • Die Konfiguration des Gerätes laden
  • Im Smart Building Automation System den Taster drücken, der den digitalen Ausgang umschalten soll. Anschließend prüfen, welcher Sensor im Programm AirConfig in der Sensoren-Liste beim Umschalten kurz aufleuchtet.
  • Den beim Umschalten kurz aufleuchtenden Sensor links zu Sensoren ziehen.
  • Die Konfiguration des Gerätes schreiben
Taster

Wenn ein Taster eingelernt werden soll, als erstes im Operator Panel des Gateways auf Neues Gerät hinzufügen klicken, im Wizard als Typ Rocker Switch 2 auswählen und dann auf Weiter klicken.

Nachdem der Taster durch Drücken des Lern-Knopfes (einer beliebigen Wippe) oder durch Eingabe der EnOcean ID hinzugefügt wurde, wird dieses Fenster angezeigt. Hier können für den Taster verschiedene Muster angelegt werden, indem eine einzelne oder mehrere Wippen gleichzeitig gedrückt werden. Für jedes Muster wird ein eigener Taster im System angelegt.

In diesem Schritt ist der Name zu vergeben und falls nötig kann dieser Taster hier einem Bereich zugeordnet werden.

Mit einem Klick auf Fertig können die eingelernten Taster zum System hinzugefügt werden. Über Neuen Taster hinzufügen können weitere Taster eingelernt werden.

Andere Geräte

Der folgende Einlernvorgang gilt nur für diese Geräte:

  • Bewegungsmelder
  • Temperaturfühler
  • Raumbediengerät
  • Fensterkontakt
  • Fenstergriff
  • Funk-Lichtaktoren (ACHTUNG: Es können nur Funk-Lichtaktoren des Typs Eltako FL62-230V (F6-02-01) eingelernt werden!)

Als erstes im Operator Panel des Gateways auf Neues Gerät hinzufügen klicken.
Danach öffnet sich der Assistent, in dem der Gerätetyp ausgewählt werden muss.

Im nächsten Schritt muss ausgewählt werden, ob das Einlernen durch Drücken des Lern-Knopfes oder durch Eingabe der EnOcean ID erfolgen soll.
ACHTUNG: Bei manchen Geräten wird zum Einlernen automatisch der Lern-Knopf ausgewählt, das heißt diese Auswahl wird übersprungen.

Wurde Drücken des Lern-Knopfes gewählt, wird zuerst überprüft, ob noch freie Kanäle vorhanden sind. Im Anschluss ist der Lern-Knopf am Gerät zu drücken.

Manche Geräte verfügen über keinen Lern-Knopf, hier reicht dann häufig eine Bedienung des Gerätes. Im Falle des Fenstergriffs, wäre dies eine Drehung des Griffs in eine beliebige Richtung.

Danach wird das Gerät automatisch hinzugefügt.

Wurde Eingabe der EnOcean ID gewählt, wird zunächst geprüft, ob noch freie Kanäle vorhanden sind. Anschließend kann die EnOcean ID des Gerätes eingegeben und das Gerät hinzugefügt werden.

Nach dem Hinzufügen eines neuen Gerätes, werden diese unter Alle Apps in der jeweiligen Kategorie angezeigt. Ein Fenstergriff ist dann zum Beispiel in der App Fenster zu finden.

Connect

Mit der App „Connect“ können Werte eines weiteren Smart Building Automation Systems im selben Netzwerk abgefragt und Methoden aufgerufen werden.
Pro Connect-Verbdinung kann ein System eingebunden werden. Für die Anbindung mehrerer Systeme können entsprechend mehrere Connect-Verbindung angelegt werden.
Damit lässt sich beispielsweise das Öffnen der Eingangstür eines Mehrparteiengebäudes umsetzen.

Die „Connect“ App ist unter „Alle Apps“ zu finden.

Erstellen

Um einen neuen Connect Client zu erstellen, navigieren Sie zur App und wählen Sie „Client hinzufügen“.

Konfiguration

In den Einstellungen können allgemeine Einstellungen für den Client vergeben werden, wie zum Beispiel die Verbindungsdaten.

Einstellungen
Client Aktiviert
Mit dieser Option lässt sich der Client deaktivieren damit er keine Daten mehr abfragt oder sendet.

Nicht erreichbar nach
Mit diesem Wert wird festgelegt, nach welcher Zeit ein Client als „nicht erreichbar“ gekennzeichnet wird.

Netzwerkeinstellungen
IP Adresse
Hier kann die IP Adresse des zweiten Smart Building Automation Systems eingeben.

Port
Hier kann der Port des zweiten Smart Building Automation Systems angeben. Standardmäßig ist dieser 80.

Benutzername
Hier kann der Benutzername für die Verbindung angegeben werden. Der entsprechende Benutzer muss im zu verbindenden Smart Building Automation System angelegt sein.

Passwort
Hier kann das Passwort für den Benutzer angeben.

Farbe und Icon
Hier dann eine Farbe und ein Icon für den Client vergeben werden, welche dann entsprechend angezeigt werden.

Damit die Netzwerkeinstellungen übernommen werden muss auf „Netzwerkeinstellungen übernehmen“ geklickt werden.

In der Bedienung können über den Button „Werte auswählen“ die Werte und Methoden ausgewählt werden, welche zur Verfügung stehen sollen.

Mit „App auswählen“ wird ein Wizard geöffnet, der die verfügbaren Werte und Methoden anzeigt und das Hinzufügen der gewünschten Elemente ermöglicht. Alternativ können Werte und Methoden über „Neue Methode hinzufügen“ oder „Neuen Wert hinzufügen“ auch manuell angelegt werden.

Nach dem Start des Wizards über „App auswählen“ werden im ersten Schritt alle verfügbaren Apps angezeigt.

Im zweiten Schritt werden alle Elemente der ausgewählten App angezeigt.

Im dritten Schritt werden alle verfügbaren Werte und Methoden angezeigt. Durch die Auswahl eines Eintrags wird der entsprechende Wert bzw. die entsprechende Methode angelegt.

Einstellungen für Werte
Attribut ID
Hier kann nachträglich geändert werden, welcher Wert abgefragt werden soll.

Zyklisch
Hier kann festgelegt werden, ob der Wert zyklisch abgefragt werden soll und in welchem Intervall die Abfrage erfolgt.

Aktualisieren
Bei Betätigung dieses Buttons wird der Wert aktualisiert.

Einstellungen für Methoden
Methoden ID
Hier kann nachträglich die Methode geändert werden, die aufgerufen werden soll.

Parameter hinzufügen
Hier können nachträglich Methoden Parameter hinzugefügt und bestehende Parameter geändert werden.

Methode aufrufen
Hiermit kann die Methode aufgerufen werden.

Bedienung

In der Bedienung des Connect Clients werden die ausgewählten Werte angezeigt und die Methoden können ausgeführt werden.

In der Ansicht unter „Werte anzeigen“ lassen sich die Methoden ebenfalls ausführen.

Außerdem können Werte und Methoden auch an anderen Stellen im System verwendet werden, beispielsweise in Szenen oder Logikprogrammen. Hierfür steht in der Auswahl im oberen Bereich der Reiter „Connect“ zur Verfügung, der alle verfügbaren Clients sowie deren Methoden und Werte enthält.

Szenen

Die Connect App bietet folgende Auslöser für Szenen (wenn ...):

  • Client wurde Offline: Der verbundene Smart Building Automation Client ist nicht mehr erreichbar
  • Client wurde Online: Der verbundene Smart Building Automation Client ist wieder erreichbar

Window

The app “windows” lets you operate and configure all windows in your system. You also have pre-defined central functions such as “open all windows” and “close all windows”.

The windows app is located under “all apps”.

Window Settings

You can configure general settings for all windows in the window settings area located under “all apps” – “settings”.

Notifications of open windows and rain/wind
If you wish to receive a notification if a window is open and it is raining or is windy, then you must activate this option.

The item “open windows” shows you a list of all open windows. The button “update” reloads the list of all open windows.

Szenen

Das Fenster bietet folgende Funktionen für Szenen (dann ...):

  • Auf Position fahren: Das Fenster wird auf eine frei wählbare Position gestellt
  • Öffnen: Das Fenster wird vollständig geöffnet
  • Schließen: Das Fenster wird vollständig geschlossen
  • Stoppen: Die aktuelle Fahrbewegung des Fensters wird gestoppt

Types Of Window

You have the possibility of integrating two types of window into your system, by window contacts or electric windows.

If you have simply just one window contact connected to a digital input, then you must create a “window contact”. However, if you have an electric window that you wish to integrate into your system, then you must create an “electric window”. Electrical windows are connected to blind modules, since they work according to the same principle.

Window Contact

Create

To create a window contact, open the window app under “all apps” and select “create window contact”. This opens the operator panel and the newly created window contact. It is important to first give the contact a name and optionally the location of the window.

Configuration

Select the digital input the window contact is connected to in the item “digital input”.

The object panel for this window contact will display whether this window is open or closed. If “open” and “closed” are reversed, i.e. the object panel shows a window to be open although it is actually closed, then activate the option “invert” in the operator panel.

You can de-activate notifications for wind and rain in the tem “notifications”.

Using With A Scene

A scene lets you react to the opening and closing of a window by selecting the triggers “has been opened” or “has been closed” in the “IF…” statement and then selecting what should happen in the “THEN ..” statement.

Electric Window

Create

To create an electric window, open the app “shading” and select the blind the window is connected to. Navigate to the parameter panel and select the “type” “window”.

Operation

You can operate an electric window either via the object panel using the arrows on the left-hand side or via the operator panel using the buttons and the slider.

Adjust Opening Times

If you know exactly how long your window takes to open and close, then enter the times directly into the fields “closing time” and “opening time”, then click on the button “use values and run reference”.

If you do not know the times, simply use the wizard to determine the opening and closing times. Follow the wizard’s instructions and the times will be automatically entered and a reference activity carried out.

Configuration

Type
If you want to convert this electric window back into a blind, then you can easily do this by selecting the type “blind”.

Except from universal scene
A universal scene “open all windows”, for example, would open all windows. However, if you wish a window to be excepted from this universal scene, then activate this option.

Lock window
This option lets you lock a window, i.e. the position cannot be changed, neither via the visualization nor via a button.

Deactivate notifications
If you do not wish to receive notifications for this window, then activate this option.

Reserve (hide in visualization)
“Reserve” lets you hide unused channels. You can unhide them via the app “hardware” and the corresponding module.

Couple With

If you want two windows to always have the same position, this can be done by coupling them. Simply select the button “select” in the item “couple with” and choose the window you wish to couple this window with.

Using With A Scene

A scene lets you react to the opening and closing of a window in that you select “has been opened” or “has been closed” in the “IF” statement and then select what should happen as a consequence in the “THEN …” statement.

You can also select the actions “go to position” (go to a window position you have defined), “open” and “close” in the “THEN” statement of a scene.

Fronius

The "Fronius" app enables the integration of a Fronius system into the Smart Building Automation System.

The Fronius app ist located under 'all apps' - 'Fronius'.

All limits, which can be configured in the Fronius app, can also be used as triggers for scenes.

Vorbereitung

Bei Fronius Gen24 Geräten kann es sein, dass die Kommunikation mit einem externen Gerät deaktiviert ist.

Um dies zu überprüfen, öffnen Sie die Weboberfläche Ihres Fronius-Geräts und navigieren Sie nach „Kommunikation - Solar API“. Stellen Sie sicher, dass die Kommunikation via Solar API aktiviert ist.

Create

To integrate your Fronius system, please follow the steps below.
(You will need the IP Adress of your PV-system for this)

Open the Fronius app an choose 'add'.

Enter the IP address of your PV system in the now appearing popup.
Confirm it with the button 'add'.

Once entered successfully, all installed elements of your PV system will be shown.

Szenen

Die Fronius App bietet folgende Auslöser für Szenen (wenn ...):

  • (Inverter) Leistungslimit 1 überschritten: Das konfigurierte Leistungslimit 1 wurde überschritten

  • (Inverter) Leistungslimit 2 überschritten: Das konfigurierte Leistungslimit 2 wurde überschritten

  • (Inverter) Leistungslimit 3 überschritten: Das konfigurierte Leistungslimit 3 wurde überschritten

  • (Inverter) Leistungslimit 1 unterschritten: Das konfigurierte Leistungslimit 1 wurde unterschritten

  • (Inverter) Leistungslimit 2 unterschritten: Das konfigurierte Leistungslimit 2 wurde unterschritten

  • (Inverter) Leistungslimit 3 unterschritten: Das konfigurierte Leistungslimit 3 wurde unterschritten

  • (Smart Meter) Bezug vom Netz begonnen: Der Strombezug vom Energieversorger-Netz hat begonnen (Es wird aktuell mehr Energie verbraucht als erzeugt)

  • (Smart Meter) Einspeisung ins Netz begonnen: Die Stromeinspeisung in das Energieversorger-Netz hat gestartet (Es wird aktuell mehr Energie erzeugt als verbraucht)

  • (Smart Meter) Netzbezugs Grenzwert 1 überschritten: Der konfigurierte Grenzwert 1 für den Netzbezug wurde überschritten

  • (Smart Meter) Netzbezugs Grenzwert 2 überschritten: Der konfigurierte Grenzwert 2 für den Netzbezug wurde überschritten

  • (Smart Meter) Netzbezugs Grenzwert 3 überschritten: Der konfigurierte Grenzwert 3 für den Netzbezug wurde überschritten

  • (Smart Meter) Netzbezugs Grenzwert 1 unterschritten : Der konfigurierte Grenzwert 1 für den Netzbezug wurde unterschritten

  • (Smart Meter) Netzbezugs Grenzwert 2 unterschritten : Der konfigurierte Grenzwert 2 für den Netzbezug wurde unterschritten

  • (Smart Meter) Netzbezugs Grenzwert 3 unterschritten : Der konfigurierte Grenzwert 3 für den Netzbezug wurde unterschritten

  • (Smart Meter) Netzeinspeisungs Grenzwert 1 überschritten: Der konfigurierte Grenzwert 1 für die Netzeinspeisung wurde überschritten

  • (Smart Meter) Netzeinspeisungs Grenzwert 2 überschritten: Der konfigurierte Grenzwert 2 für die Netzeinspeisung wurde überschritten

  • (Smart Meter) Netzeinspeisungs Grenzwert 3 überschritten: Der konfigurierte Grenzwert 3 für die Netzeinspeisung wurde überschritten

  • (Smart Meter) Netzeinspeisungs Grenzwert 1 unterschritten: Der konfigurierte Grenzwert 1 für die Netzeinspeisung wurde unterschritten

  • (Smart Meter) Netzeinspeisungs Grenzwert 2 unterschritten: Der konfigurierte Grenzwert 2 für die Netzeinspeisung wurde unterschritten

  • (Smart Meter) Netzeinspeisungs Grenzwert 3 unterschritten: Der konfigurierte Grenzwert 3 für die Netzeinspeisung wurde unterschritten

  • (Batterie) Mindestladung 1 überschritten: Der konfigurierte Wert der Mindestladung 1 wurde überschritten

  • (Batterie) Mindestladung 2 überschritten: Der konfigurierte Wert der Mindestladung 2 wurde überschritten

  • (Batterie) Mindestladung 3 überschritten: Der konfigurierte Wert der Mindestladung 3 wurde überschritten

  • (Batterie) Mindestladung 1 unterschritten: Der konfigurierte Wert der Mindestladung 1 wurde unterschritten

  • (Batterie) Mindestladung 2 unterschritten: Der konfigurierte Wert der Mindestladung 2 wurde unterschritten

  • (Batterie) Mindestladung 3 unterschritten: Der konfigurierte Wert der Mindestladung 3 wurde unterschritten

Zu beachten ist, dass es sich bei den Auslösern von Szenen nur um Ereignisse handelt. Ein Ereignis wird nur zu einem kurzen Zeitpunkt aktiv (z.B.: Bezug vom Netz hat begonnen) und kann zu diesem Zeitpunkt verwendet werden um andere Funktionen auszulösen (z.B: Heizstab Boiler ausschalten). Zum Erstellen von komplexeren Abläufen bietet sich die Smart Building Automation Logik an.

Elements

If a Fronius system is integrated, all installed elements of the PV system that are supported by the Smart Building Automation System are displayed.
Additionally, the dashboard of the "Fronius" app can be extended with additional panels.

Once a PV system has been integrated, additional panels can be added using the 'add' button.

The available panels include 'My Fronius', which provides an overview of the current energy flow in the system, as well as "Efficiency" (of the inverter), “Energy“, "Supply" and "Phase Distribution".

A dynamic diagram is also available and can be configured as required. Different values and diagram types can be selected.

All panels can be added to the home screen by selecting them with a long click/press.

Inverter

Operation
The most important values are displayed in the first part of the detail view (Operator Panel).

Additionally, the utilization and energy values for year, month and week will be shown in a diagram.

Configuration
The second part of the detail view (Parameter Panel) allows you to view detailed values and and adjust limits. Three power limits can be set which will trigger an event once exceeded or below the set value.

Detail values
Lists values which can be used by an inverter in the system.

Scenes
The inverter offers an event for the power limits 1,2 and 3 in case they are exceeded (above/below).

Smart Meter

Operation
The operator panel of the Smart Meter displays the current feed-in/supply to or from the power grid and presents them in an area diagram.

Configuration
The parameter panel displays the phase distribution in a bar chart and allows you to adjust feed-in/supply limits for he power grid, which will throw an event once exceed (below/above). In addition, all detail values of the Smart Meter are displayed.

Detail values
Shows values which can be used by a Smart Meter in the system.

Scenes
The Smart Meter offers events for feed-in/supply to or from the power grid in case they are exceeded (above/below).

Battery

Operation
The operator panel displays the current charging/discharging rate (in watt) and the current battery power level.

Configuration
The parameter panel allows you to adjust the minimum charging level, which will trigger an event in case it is exceed (above/below), and to view the detail values of the battery.

Detail values
Shows values which can be used by a battery in the system.

Scenes
The battery offers events for exceeding (above/below) the minimum charging limit.

Gardena

Für die Einbindung von Gardena Geräten ist eine Anmeldung in der Husqvarna App des Smart Building Automation Systems mit einem Gardena Account erforderlich. Diese sind unter Einstellungen > Gardena zu finden.

Erstellen

Durch einen Klick auf Anmelden wird ein Wizard gestartet.

Falls der externe Zugriff nicht aktiviert ist, kann er im angezeigten Wizard durch einen Klick auf Externen Zugriff aktivieren aktiviert werden. Dies ist für den nächsten Schritt erforderlich.

Ist der externe Zugriff bereits aktiviert oder wurde er aktiviert, folgt durch einen Klick auf Verbinden die Weiterleitung zum Gardena-Portal . Sollte der externe Zugriff nur für die Anmeldung aktiviert worden sein, kann er nach der Anmeldung wieder deaktiviert werden.

Sind in der mobilen Gardena App mehrere Gärten angelegt, kann hier der gewünschte Garten ausgewählt werden. Anschließend werden die zugehörigen Geräte angezeigt, die dem System hinzugefügt werden können. Ist nur ein Garten vorhanden, werden dessen Geräte automatisch angezeigt. Die Geräte können einzeln oder gemeinsam hinzugefügt werden.

ACHTUNG! Es können nur Geräte aus einem Garten in das System eingebunden werden.

Bedienung

Im Gardena Object Panel wird der Verbindungsstatus zum verwendeten Account angezeigt.

Mit einem Klick auf das Gardena Object Panel öffnet sich das statische Operator Panel. Hier können weitere Geräte hinzugefügt werden.

Im Parameter Panel kann sich wieder aus der Gardena App ausgeloggt werden.

Rasenmäher

Alle integrierten Mähroboter werden zur Mähroboter-App, welche unter Alle Apps > Mähroboter zu finden ist, hinzugefügt.

Das Operator Panel des Mähroboters zeigt den aktuellen Status, Zusatzinformationen und den aktuellen Batteriestand und den Bereich an.
Außerdem kann hier der Mäher gestartet, geparkt und mit dem Zeitplan fortgesetzt werden.

Beim Starten kann eine Zeit angegeben werden, welche die Dauer des Mähvorgangs bestimmt.

Beim Parken kann ausgewählt werden, ob der Mäher bis zur nächsten Zeitplan Einstellung oder über eine gewisse Dauer geparkt werden soll.

Im Parameter Panel des Mähroboters kann der Bereich ausgewählt werden, in dem das Gerät angezeigt werden soll.

Unter Informationen wird das Modell und die Seriennummer angezeigt.

Zusätzlich kann unter Einstellungen der Status des Mähroboters neu geladen werden.

Ventil

Alle integrierten Ventile werden zur Bewässerungs-App, welche unter Alle Apps > Bewässerung zu finden ist, hinzugefügt.

Gardena Ventile können zu zwei verschiedenen Geräten gehören:

  1. Zu Smart Irrigation Control, welches bis zu 6 Ventile steuern kann
  2. Zu Smart Water Control, welches ein einzelnes Ventil steuern kann

Die Geräte Smart Irrigation Control und Smart Water Control werden unter Einstellungen > Gardena angezeigt.

Im Operator Panel werden die allgemeinen Informationen der Geräte angezeigt und über die Schaltfläche Geräte anzeigen kann zu den einzelnen Ventilen navigiert werden.

Im Parameter Panel kann zudem der Bereich gewählt werden.

ACHTUNG: Beim Gerät Smart Irrigation Control können immer nur maximal zwei Ventile gleichzeitig geöffnet sein!

Im Operator Panel eines Ventils kann dieses geöffnet, geschlossen, der Zeitplan pausiert oder fortgesetzt werden.

Im Parameter Panel kann wiederum der Bereich gewählt werden.

Bodensensor

Alle integrierten Bodensensoren werden zur Bewässerungs-App, welche unter Alle Apps > Bewässerung zu finden ist, hinzugefügt.

Im Operator Panel wird die gemessene Feuchtigkeit, Temperatur sowie die Zeit der letzten Messung angezeigt.
Zusätzlich wird der Status der RF Signals sowie der Batterie angezeigt.

Im Parameter Panel kann zudem der Bereich gewählt werden.

Steckdose

Alle integrierten Steckdosen werden zur Steckdosen-App, welche unter Alle Apps > Steckdosen zu finden ist, hinzugefügt.

Im Operator Panel wird der Zustand der Steckdose angezeigt welcher mittels einem Klick auf Umschalten geändert werden kann.

Im Parameter Panel kann zudem der Bereich gewählt werden.

Szenen

Der Mähroboter bietet folgende Auslöser für Szenen (wenn ...):

  • Auf dem Weg zur Ladestation: Der Mähroboter hat sich gerade auf den Weg zur Ladestation begeben
  • Laden wurde gestartet: Der Mähroboter wird nun geladen
  • Mähen wurde gestartet: Der Mähroboter hat das Mähen gestartet
  • Manueller Start des Mähers benötigt: Der Mähroboter muss manuell gestartet werden
  • Verlässt die Ladestation: Der Mähroboter verlässt nun die Ladestation
  • Wurde geparkt: Der Mähroboter wurde geparkt

Der Mähroboter bietet folgende Funktionen für Szenen (dann ...):

  • Parken bis auf weiteres: Der Mähroboter parkt, bis ein erneuter Befehl gesendet wird
  • Parken bis zur nächsten Zeitplan Einstellung: Der Mähroboter parkt bis zur nächsten Zeitplan Einstellung
  • Starten für: Der Mähroboter startet über den ausgewählten Zeitraum und ignoriert die Zeitplan Einstellungen
  • Zeitplan fortsetzen: Der Mähroboter beendet den letzten Befehl und fährt wieder nach Zeitplan

Das Ventil bietet folgende Funktionen für Szenen (dann ...):

  • Öffnen: Das Ventil wird geöffnet
  • Öffnen für: Das Ventil wird für eine bestimmte Zeit geöffnet (maximal 90 Minuten)
  • Schließen: Das Ventil wird geschlossen
  • Zeitplan fortsetzen: Der Zeitplan wird fortgesetzt
  • Zeitplan pausieren: Der Zeitplan wird für eine bestimmte Zeit pausiert (maximal 7 Tage)

Die Steckdose bietet folgende Funktionen für Szenen (dann ...):

  • Ausschalten: Die Steckdose wird ausgeschalten
  • Einschalten: Die Steckdose wird eingeschalten
  • Einschalten für: Die Steckdose wird für eine bestimmte Zeit eingeschalten
  • Umschalten: Die Steckdose wird umgeschalten

Logik

Der Mähroboter bietet folgende Möglichkeiten zur Verwendung in Logiken:

  • Fehler (lesen): Trifft zu, wenn ein Fehler besteht
  • Lädt (lesen): Trifft zu, wenn der Mähroboter gerade geladen wird
  • Mäht (lesen): Trifft zu, wenn der Mähroboter gerade mäht

Das Ventil bietet folgende Möglichkeiten für zur Verwendung in Logiken:

  • Geöffnet (lesen und schreiben): Ob das Ventil geöffnet ist
  • Fehler (lesen): Trifft zu, wenn ein Fehler besteht

Der Bodensensor bietet folgende Möglichkeiten für zur Verwendung in Logiken:

  • Fehler (lesen): Trifft zu, wenn ein Fehler besteht
  • Bodenfeuchte (lesen): Bodenfeuchte in Prozent
  • Bodentemperatur (lesen): Bodentemperatur in °C

Die Steckdose bietet folgende Möglichkeiten für zur Verwendung in Logiken:

  • Fehler (lesen): Trifft zu, wenn ein Fehler besteht
  • Wert (lesen und schreiben): Der Zustand der Steckdose

House Status

The “house status” displays the current status of your house and lets you change it.

The “house status” is located under “all apps” – “house status”.

Create

A new building status can easily be added by selecting “create status”. The operator panel then opens, where a name for the building status can be defined. Once a name has been assigned, the configuration can be continued (described below).

Each building status can be assigned a name and an icon. These are displayed in the Smart Building Automation System.

Configuration

For each of your created house stati, you can define which button activates it and should happen if the status changes.

Button to activate this status
Select the button here that allows you to activate the corresponding status

Action when activated
Select here the action that is to be invoked when the corresponding house status is activated.

Action when de-activated
Select here the action that is to be invoked when the corresponding house status is de-activated

Usage

If you want to activate a status via the visualization, you can do this either in the left-hand area of the corresponding object panel or via the operator panel using the button “execute”.

The status that is currently active is displayed both in the object panel and in the house status panel. If you drag the house status to your favourites, then the current active status is displayed there too.

The house status panel not only displays the current status of your house, but also if dawn/dusk, rain or wind are active. You can configure where this information comes from in the “global settings”.

Szenen

Der Hausstatus bietet folgende Auslöser für Szenen (wenn ...):

  • Aktiviert: Der ausgewählte Hausstatus wurde aktiviert
  • Deaktiviert: Der ausgewählte Hausstatus wurde deaktiviert

Der Hausstatus bietet folgende Funktionen für Szenen (dann ...):

  • Aktivieren: Der gewählte Hausstatus wird aktiviert

Hardware

The hardware app lists all modules that are connected to your system. If you wish to obtain a list of module channels, then all elements in this module are clearly displayed and in the correct order, the way they are connected to the module. This view can make it much simpler for you to name the individual elements, since you immediately know which module and which channel you wish to name.

The hardware app is located under “all apps” – “hardware”.

Hierarchically above the modules, you can see which line the module is located in (e.g. SC1 – line 1).

TechCOM-Linie

Wenn Sie die TechCOM-Linie öffnen, sehen Sie die Anzahl der verbundenen Module und können nach neuen suchen.

Line

If you open the line, the first thing you will see at the top is general information about the line. The item “cycle time” lets you define the cycle time for your bus line (standard is 200 ms). “Required cycle time” shows the time that is required for the operations. “Total cycle time” is the time required by the bus for a cycle. “Peak” is the peak value of the cycle time. This can be reset using the button “reset peak”.

Modules

By opening a module (click on the right-hand area), you will see all necessary information pertaining to this module. The button “display channels” displays the available channels in this module. The button “reset” resets a module, meaning that this module is reset to factors settings.

Module Channels

Click on the left-hand are of the object panel or on the button “displays channels) in the operator panel to see a list of module channels. Taking a light module as an example, you will be able to see the four channels with their corresponding button/movement detector and a light. This is the exact order that the button/movement detector and light are connected to the module, i.e. channel 1 is the light that is connected on the far left of the module.

Universalmodul (U1208)

Das Universalmodul U1208 verfügt über 8 Digitale Ausgänge, diese können so konfiguriert werden, dass diese die Funktion eines Licht-, Beschattungs- oder Digitalmoduls ohne Autarkfunktion übernehmen. Hierbei können die Funktionen am Modul auch gemischt betrieben werden.

Nach dem Verbinden des Universalmoduls ist dieses als 8-fach Digital-Ausgangsmodul konfiguriert. Über das Operator Panels des Moduls, kann die Konfiguration geändert werden.

Hierzu müssen die Kanäle, welche angepasst werden sollen angeklickt werden, danach kann über das Dropdown „Typ“, der gewünschte Typ ausgewählt werden.
Nachdem die Konfiguration wie gewünscht eingestellt wurde, muss diese mit „Konfiguration übernehmen“ gespeichert werden.

Zur Auswahl stehen die Typen der 4 Funktionsgruppen Digitale Ausgänge, Licht, Beschattung und Raumklima.

Digitale Ausgänge
Im Modus Digitaler Ausgang bietet der Ausgang die selbe Funktionalität wie Ausgänge von Digitalmodulen. Weitere Informationen

Licht
Im Modus Licht bietet der Ausgang die selbe Funktion wie ein schaltbares Licht, jedoch ohne Autark-Taster/Bewegungsmelder. Weitere Informationen

Beschattung
Für den Modus Beschattung werden immer 2 Ausgänge benötigt, diese müssen nebeneinander liegen (mögliche Konfigurationen: Kanal 1 & 2, Kanal 3 & 4, Kanal 5 & 6 und Kanal 7 & 8 können jeweils eine Beschattung abbilden). In diesem Modus bieten die beiden Ausgänge die selbe Funktion wie Beschattungsausgänge, jedoch ohne Autark-Taster. Weitere Informationen

Raumklima (Raumklima Ventil)
Im Modus Raumklima bietet der Ausgang die selbe Funktion wie ein Ausgang der Raumklima Module, jedoch mit externer Istwert Vorgabe. Weitere Informationen

Home Connect

Mit der App „Home Connect“ können Home Connect Geräte in das Smart Building Automation System integriert werden.

Die Home Connect App ist unter „Einstellungen“ - „Home Connect“ zu finden.

Aktuell werden folgende Geräte unterstützt:

  • Trockner
  • Waschmaschine
  • Geschirrspüler
  • Kaffeemaschine
  • Ofen

ACHTUNG: Es können nur Geräte integriert werden, die bereits mit einem Home Connect Account verknüpft sind. Um Geräte mit dem Home Connect Account zu verknüpfen, muss die Home Connect App verwendet werden. Weitere Informationen sind unter folgendem Link zu finden: https://www.home-connect.com/de/de/home

Einbindung

Durch einen Klick auf „Anmelden“, wird ein Wizard gestartet.

Falls der externe Zugriff nicht aktiviert ist, kann er im angezeigten Wizard durch einen Klick auf Externen Zugriff aktivieren aktiviert werden. Dies ist für den nächsten Schritt erforderlich.

Ist der externe Zugriff bereits aktiviert oder wurde er aktiviert, folgt durch einen Klick auf Verbinden die Weiterleitung zum Home Connect Portal. Sollte der externe Zugriff nur für die Anmeldung aktiviert worden sein, kann er nach der Anmeldung wieder deaktiviert werden.

Nach erfolgreicher Anmeldung erfolgt die Weiterleitung zurück zum Smart Building Automation System. Im Wizard werden anschließend alle Geräte angezeigt, die bereits mit dem Home Connect Account verknüpft sind.
Zu Beginn sind alle Geräte ausgewählt. Mit einem Klick auf „Hinzufügen“ werden alle ausgewählten Geräte eingebunden. Sollen nur bestimmte Geräte eingebunden werden, können die übrigen Geräte abgewählt werden.

Nach dem erfolgreichen Hinzufügen der ausgewählten Geräte wird eine entsprechende Bestätigung im Wizard angezeigt. Anschließend kann der Wizard mit einem Klick auf „Fertig“ beendet werden.

Konfiguration

Neben der Anmeldung mit dem Home Connect Account, wie im Abschnitt „Einbindung“ beschrieben, ist keine weitere Konfiguration erforderlich.
Weitere Geräte können jederzeit über die Home Connect App hinzugefügt werden. Dazu im Operator Panel auf „Neue Geräte hinzufügen“ klicken.

Im Parameter Panel der Home Connect App kann die Verbindung zum Home Connect Account getrennt werden. Dadurch werden alle integrierten Geräte sowie deren zugehörige Verknüpfungen (z. B. Szenen und Logiken) aus dem System entfernt.

Bedienung

Alle integrierten Geräte werden zur Haushaltgeräte App hinzugefügt, die unter „Alle Apps“ - „Haushaltgeräte“ zu finden ist.

Zwischen den Geräten gibt es in der Bedienung teilweise Unterschiede.
Folgende Geräte können Ein- und Ausgeschaltet werden:

  • Kaffeemaschine
  • Geschirrspüler
  • Ofen

Bei folgenden Geräten kann ein laufendes Programm pausiert werden:

  • Ofen
  • Waschmaschine
  • Trockner

Bei folgenden Geräten kann ein pausiertes Programm fortgesetzt werden:

  • Ofen
  • Waschmaschine
  • Trockner
  • Geschirrspüler

Im Operator Panel eines Geräts wird der Status sowie das entsprechende Bild des Geräts angezeigt.
Darunter kann das Gerät ein- oder ausgeschalten werden (ACHTUNG: Wie bereits oben erwähnt, nicht bei jedem Gerät möglich). Zudem wird mit einem Klick auf „Programmauswahl“ ein Wizard geöffnet, in welchem ein Programm konfiguriert, gestartet und als Favorit gespeichert werden kann.

Nachdem auf „Programmauswahl“ geklickt wurde, können das Programm und verschiedene Zusatzoptionen ausgewählt werden, wobei diese je nach Programm variieren können.

Nach einem Klick auf „Weiter“ werden die gewählten Einstellungen aufgelistet. Wenn Sie diese Einstellungen abspeichern möchten, klicken Sie auf „Als Favorit speichern“. Andernfalls können Sie die Einstellungen bestätigen und das Programm starten.

Wenn Sie das Programm als Favorit speichern wollen, werden Sie auf die nächste Seite weitergeleitet, in der Sie dem Favoriten einen Namen vergeben müssen und können danach mit einem Klick den Favorit speichern und gleichzeitig das Programm starten.

Entsprechend den getätigten Einstellungen kann es auch sein, dass das Programm erst später startet. In diesem Fall wird die verbleibende Zeit bis zum Programmstart angezeigt.

Sobald das Programm gestartet wurde, wird der Wizard automatisch geschlossen und im Operator Panel erscheint der Programmfortschritt als Ladebalken. Über diesem wird entweder der Programmfortschritt in Prozent oder die verbleibende Zeit angezeigt.

Im Parameter Panel werden alle hinzugefügten Favoriten angezeigt. Mit einem Klick auf das Stift-Symbol öffnet sich ein Fenster, in welchem Sie die einzelnen Einstellungen des Favoriten ändern können.

Szenen

Die Haushaltsgeräte App bietet folgende Auslöser für Szenen (wenn ...):

  • Programm wurde gestartet: Programm wurde gestartet
  • Programm wurde beendet: Programm wurde beendet
  • Programm wurde pausiert (Vorhanden bei: Ofen, Trockner, Waschmaschine): Programm wurde pausiert

Die Haushaltsgeräte App bietet folgende Funktionen für Szenen (dann ...):

  • Einschalten (Vorhanden bei: Kaffeemaschine, Geschirrspüler, Ofen): Gerät einschalten
  • Ausschalten (Vorhanden bei: Kaffeemaschine, Geschirrspüler, Ofen): Gerät ausschalten
  • Favorit starten: Ein ausgewählter Favorit wird gestartet
  • Programm pausieren (Vorhanden bei: Ofen, Trockner, Waschmaschine): Ein laufendes Programm wird pausiert
  • Programm fortsetzen (Vorhanden bei: Geschirrspüler, Ofen, Trockner, Waschmaschine): Ein pausiertes Programm wird fortgesetzt

Verwendung im Energiemanagement

Damit HomeConnect Geräte im Energiemanagement verwendet werden können, muss zuerst in der HomeConnect App für jedes zu steuernde Gerät unter Einstellungen - Fernsteuerungs Level das Fernsteuerungslevel Manueller Fernstart ausgewählt sein.

Danach folgende Einstellungen direkt am Gerät tätigen:

  1. Das gewünschte Programm auswählen
  2. Die Startfreigabe aktivieren

ACHTUNG: Es genügt nicht, wenn das Gerät eingeschaltet wird und das gewünschte Programm bereits automatisch ausgewählt ist. Bitte in diesem Fall zunächst ein anderes Programm und anschließend erneut das gewünschte Programm auswählen.

Wenn das Gerät noch immer nicht gestartet werden kann, bitte einmal das Gerät aus- und wieder einschalten und den Vorgang wiederholen.

Husqvarna

Für die Einbindung von Husqvarna Geräten ist eine Anmeldung mit einem Husqvarna Account erforderlich. Die Husqvarna App ist unter Einstellungen > Husqvarna zu finden.

Erstellen

Durch einen Klick auf Anmelden wird ein Wizard gestartet.

Falls der externe Zugriff nicht aktiviert ist, kann er im angezeigten Wizard durch einen Klick auf Externen Zugriff aktivieren aktiviert werden. Dies ist für den nächsten Schritt erforderlich.

Ist der externe Zugriff bereits aktiviert oder wurde er aktiviert, folgt durch einen Klick auf Verbinden die Weiterleitung zum Husqvarna-Portal . Sollte der externe Zugriff nur für die Anmeldung aktiviert worden sein, kann er nach der Anmeldung wieder deaktiviert werden.

In diesem Schritt werden automatisch die Geräte des verwendeten Accounts angezeigt, die dem System hinzugefügt werden können. Dabei können einzelne oder alle Geräte ausgewählt werden.

Bedienung

Im Husqvarna Object Panel wird der Verbindungsstatus zum verwendeten Account angezeigt.

Mit einem Klick auf das Husqvarna Object Panel öffnet sich das statische Operator Panel. Hier können weitere Geräte hinzugefügt werden.

Im Parameter Panel kann sich wieder aus der Husqvarna App ausgeloggt werden.

Rasenmäher

Alle integrierten Mähroboter werden zur Mähroboter-App, welche unter Alle Apps > Mähroboter zu finden ist, hinzugefügt.

Das Operator Panel des Mähroboters zeigt den aktuellen Status, Zusatzinformationen, den aktuellen Batteriestand und den Bereich an, in welchem sich der Mähroboter gerade bedient.
Außerdem kann hier der Mäher gestartet, geparkt und pausiert werden.

Beim Starten kann eine Zeit angegeben werden, welche die Dauer des Mähvorgangs bestimmt.

Beim Parken kann ausgewählt werden, ob der Mäher bis zur nächsten Zeitplan Einstellung oder über eine gewisse Dauer geparkt werden soll.

Im Parameter Panel des Mähroboters kann der Bereich ausgewählt werden, in dem das Gerät angezeigt werden soll.

Unter Informationen wird das Modell und die Seriennummer angezeigt.

Zusätzlich kann unter Einstellungen der Status des Mähroboters neu geladen werden.

Szenen

Der Mähroboter bietet folgende Auslöser für Szenen (wenn ...):

  • Auf dem Weg zur Ladestation: Der Mähroboter hat sich gerade auf den Weg zur Ladestation begeben
  • Laden wurde gestartet: Der Mähroboter wird nun geladen
  • Mähen wurde gestartet: Der Mähroboter hat das Mähen gestartet
  • Manueller Eingriff benötigt: Der Mähroboter steht und benötigt einen manuellen Eingriff
  • Manueller Start des Mähers benötigt: Der Mähroboter muss manuell gestartet werden
  • Verlässt die Ladestation: Der Mähroboter verlässt nun die Ladestation
  • Wurde geparkt: Der Mähroboter wurde geparkt

Der Mähroboter bietet folgende Funktionen für Szenen (dann ...):

  • Parken bis auf weiteres: Der Mähroboter parkt, bis ein erneuter Befehl gesendet wird
  • Parken bis zur nächsten Zeitplan Einstellung: Der Mähroboter parkt bis zur nächsten Zeitplan Einstellung
  • Parken für: Der Mähroboter parkt über den gewählten Zeitraum
  • Pause: Der Mähroboter pausiert das mähen bis ein erneuter Befehl gesendet wird
  • Starten für: Der Mähroboter startet über den ausgewählten Zeitraum und ignoriert die Zeitplan Einstellungen
  • Zeitplan fortsetzen: Der Mähroboter beendet den letzten Befehl und fährt wieder nach Zeitplan

Logik

Der Mähroboter bietet folgende Möglichkeiten zur Verwendung in Logiken:

  • Fehler (lesen): Trifft zu, wenn ein Fehler besteht
  • Lädt (lesen): Trifft zu, wenn der Mähroboter gerade geladen wird
  • Mäht (lesen): Trifft zu, wenn der Mähroboter gerade mäht

Camera

The "Camera" app enables the integration of a SchrackCAM into the Smart Building Automation System.

The Camera app is located under "all apps" – "Camera".

Create

In order to create a camera, click on the box “add new SchrackCAM” inside the app.

All found SchrackCAMs including a preview image will now be listed in the popup which appears. Once a camera shows up on this list you can select it and it will be added to your system and is ready to be used.

If the camera is not found within network, the search can be restarted or the camera can be configured manually. For manual configuration, a camera is added to the system and the required settings (IP address, username, and password) must be entered.

Configuration

To configure the camera correctly, the camera's IP address must be entered in the browser.

If the camera was automatically detected and added as described in the create section, no further configuration is required.

For manual integration, for example if the camera could not be found automatically within the network, the required settings can be entered or changed at any time in the camera's Parameter Panel.

The settings may also need to be adjusted if the default username or password has been changed or if the IP address changes.

If the camera credentials (username/password) are changed via its web interface, the app or browser may request the new credentials.

In this case, the new credentials must also be updated in the camera's Parameter Panel. Otherwise, the credentials may be requested repeatedly.

A specific static IP address can also be assigned to the camera. When this setting is changed, the new network configuration is transferred to the camera. The camera then restarts with the new configuration.

When the IP address is changed, other relevant network settings, such as the gateway and subnet mask, are taken from the current network configuration of the Smart Building Automation System. For individual configuration of these settings, an advanced form is available under “Additional Parameters”.

Operation

The camera panel supports two different sizes. If you hold down your finger (cursor+left mouse button) on the panel for some seconds a bar will appear on the bottom of your screen, which gives you the ability to change the size from small to large.

The large size supports displaying the current camera video inside the panel. Like most other panels, you can add this to your favorites on the start screen which will allow you to always see the current camera image.

With the icon located on the top right corner of the camera image, you can open a popup with bigger view of the video stream, which is well suited for bigger screen sizes like tablets.

The camera OperatorPanel displays the current video/image if the correct credentials are added in the settings. You can also open a popup containing a bigger sized version of the camera image by clicking the icon in the top right corner of the image.

If you did not enter a name for the camera yet, the associated input field will also appear here.

Szenen

Die Kamera bietet folgende Auslöser für Szenen (wenn ...):

  • Bewegung wurde erkannt: Es wurde von der Kamera eine Bewegung erkannt

Logik

Die Kamera bietet folgende Möglichkeiten für die Verwendung in Logiken:

  • Bewegung erkannt: Ob aktuell eine Bewegung erkannt wurde (lesen)
  • Fehler: Ob ein Fehler aktiv ist (lesen)

Klimageräte

Diese App ermöglicht es, verschiedene Klimageräte einzulernen.

Die App kann unter „Alle Apps“ gefunden werden.

Erstellen

Wurde in die Klimageräte-App navigiert, kann durch Klick auf „Hinzufügen“ der Installations-Wizard gestartet werden.

Über Daikin Cloud können cloudfähige Klimageräte von Daikin hinzugefügt werden.
Weitere Informationen sind dem Kapitel Daikin zu entnehmen

Über die RT-NET Schnittstelle können Daikin-Klimaanlagen der Baureihe VRV und SkyAir und Belüftungsgeräte der Baureihe VAM und VKM gesteuert werden.

RTD-NET

Erstellen

Bei Modbus RTD-NET Geräten muss den Schritten im Wizard über die Modbus Schnittstelle gefolgt werden. Es ist jene Schnittstelle auszuwählen über die das Klimagerät verbunden ist. Danach wird nach angeschlossenen Klimageräten mit Slave Adressen bis Adresse 16 gesucht. Es werden alle gefundenen Adressen angezeigt und die Geräte können hinzugefügt werden.

Achtung! Bei Daikin RTD-NET Geräten können pro Schnittstelle maximal 8 Geräte angeschlossen werden.

Konfiguration

Neben der Vergabe eines Namens und der Zuordnung zu einem Raum, können hier weitere Gerätedaten eingesehen werden.

Bedienung

Wurde das Daikin Klimagerät erfolgreich in das Smart Building Automation System eingebunden, stehen mehrere Bedienelemente zur Verfügung.

Es kann die Soll-Temperatur eingestellt und das Gerät ein- und ausgeschaltet werden.

Unter Betriebsmodus lässt sich der Modus auf Auto, Heizen, Kühlen, Ventilator und Trocknen stellen.

Außerdem lässt sich die Lüftungsstufe verstellen.

Unter Lamellenstellung lässt sich die Lamelle entweder auf „Schwenken“ stellen oder auf einen bestimmten Winkel.

Szenen

Die Daikin RTD bietet folgende Auslöser für Szenen (wenn ...):

  • Filteralarm: An mindestens einem Gerät liegt ein Filteralarm vor
  • Störung aufgetreten: Am Klimagerät liegt eine Störung vor oder die Verbindung zum Gerät wurde verloren
  • Wurde Ausgeschaltet: Das Klimagerät wurde ausgeschaltet
  • Wurde Eingeschaltet: Das Klimagerät wurde eingeschaltet

Die Daikin RTD bietet folgende Funktionen für Szenen (dann ...):

  • Ausschalten: Das Klimagerät wird ausgeschaltet
  • Betriebsmodus setzen: Ein frei auswählbarer Betriebsmodus (Heizen, Kühlen, ...) wird als Vorgabe an das Gerät gesendet
  • Einschalten: Das Klimagerät wird eingeschaltet
  • Einschalten mit Optionen: Das Klimagerät wird mit verschiedenen frei wählbaren Parametern eingeschaltet
  • Lamellenwinkel setzen: Der gewählte Lamellenwinkel wird als Vorgabe an das Gerät gesendet
  • Lüftungsstufe setzen: Eine frei auswählbare Lüftungsstufe wird als Vorgabe an das Gerät gesendet
  • Soll Temperatur setzen: Eine frei wählbare Soll-Temperatur wird an das Gerät gesendet

Kurzbefehle / Widgets

Um Aktionen in Ihrem Zuhause mit nur einem Klick ausführen zu können, empfiehlt sich die Konfiguration von Kurzbefehlen und Widgets.

iOS

Mithilfe der App „Kurzbefehle“ können Szenen schnell und einfach ausgeführt werden.

Zum Anlegen und Verwalten der Kurzbefehle die App „Kurzbefehle“ öffnen.

Mittels Klick auf das „+“ können neue Kurzbefehle angelegt werden. Es empfiehlt sich, die Kurzbefehle in Ordnern zu Gruppieren, da diese später in den Widgets ausgewählt werden können. Kurzbefehle können jedoch jederzeit in andere Ordner verschoben werden.

Nach dem Anlegen eines Kurzbefehls kann dieser benannt sowie ein Icon und eine Farbe konfiguriert werden. In einem Kurzbefehl können durch Klick auf „Aktion hinzufügen“ beliebig viele Aktionen hinzugefügt werden.

Unter Apps finden Sie die App „Smart Home“. Durch Klick auf die App kann die Aktion „Szene ausführen“ hinzugefügt werden.

Durch Klick auf den blau hinterlegten Wortlaut „Szene“ werden ihre Szenen geladen und können anschließend ausgewählt werden. Dies kann einige Sekunden dauern.

Alternativ können sie durch Auswahl von „Jedes mal nachfragen“ einen dynamischen Kurzbefehl erzeugen. Welche Szene ausgeführt wird, kann dann beim Ausführen ausgewählt werden.

Sollten Sie mehrere Controller besitzen, kann durch Aufklappen der Aktion der Controller ausgewählt werden.

Am unteren Bildschirmrand kann der jeweilige Kurzbefehl mithilfe des „Teilen-Buttons“ auf den Home-Bildschirm hinzugefügt werden. Dabei kann dieser anders benannt werden.

Kurzbefehle können auch als Widget in unterschiedlichen Größen auf den Home Bildschirm gelegt werden.

Dazu muss durch gedrückt halten einer beliebigen App der Home-Bildschirm in den Bearbeitungsmodus gewechselt werden. Mittels „+“ in der oberen linken Bildschirmecke können Widgets hinzugefügt werden. Hier kann die App Kurzbefehle ausgewählt werden und anschließend in beliebiger Größe frei platziert werden.

Durch gedrückt halten auf das neu hinzugefügte Widget kann das Widget bearbeitet werden. Dabei kann ein Ordner ausgewählt werden. Dies erleichtert die Gruppierung von Kurzbefehlen.

Ähnlich der Kurzbefehle können in der Kurzbefehle-App auch Automationen erstellt werden. Dabei können Szenen aufgrund bestimmter Ereignisse ausgeführt werden. Ereignisse können beispielsweise das Verlassen des Gebäudes oder das Verbinden mit einem WLAN oder Bluetooth sein.

Android

Mithilfe von Widgets können Szenen schnell und einfach ausgeführt werden.

Die folgende Beschreibung kann je nach Gerät leicht variieren.

Drücken Sie am Starbildschirm Ihres Android Smartphones lange auf den Bildschirm und wählen Sie „Widgets hinzufügen“

Selektieren Sie das „Szenen“ Widget unter „Smart Home“, indem Sie es lange gedrückt halten und dann am Bildschirm platzieren.

Wenn Sie über mehrere Verbindungen in Ihrer Merkliste verfügen, dann selektieren Sie die gewünschte Verbindung, ansonsten wird automatisch der nächste Schritt gestartet.

Wählen Sie die Szene aus, welche Sie über das Widget starten wollen.

Sie können nun auch noch ein Symbol und eine Farbe für das Widget vergeben. Nach dem Klick auf „Übernehmen“ wird das Widget zu Ihrem Startbildschirm hinzugefügt.

Durch einen Klick auf das Widget wird die Szene ausgeführt.

KNX

Mit der App „KNX” können KNX Geräte in das Smart Building Automation System eingebunden werden. Hierfür wird ein „TK100“ Modul benötigt.

Erstellen

Sobald ein Modul angeschlossen wird, wird es vom System erkannt und das Modul unter Hardware - techCOM Linie hinzugefügt.

ACHTUNG: Pro Smart Building Automation System wird nur ein KNX Modul unterstützt. Dieses darf höchstens das achte Modul in der techCOM-Linie vom Controller links ausgehend sein!

Wenn man im Operator Panel auf den Button Bearbeiten klickt, wird zur Konfiguration der einzelnen Datenpunkte gewechselt, worauf hin das Panel Datenpunkt hinzufügen sowie alle bereits hinzugefügten Datenpunkte gruppiert angezeigt werden. Die Datenpunkte sind nach Gruppen sortiert, wenn z.B. die Datenpunkte „0/0/1“ und „0/1/1“ vorhanden sind, dann wird in der ersten Ebene die Hauptgruppe „0“ angezeigt. Wenn dann auf die Hauptgruppe „0“ geklickt wird, wird in Hauptgruppe navigiert und die beiden Mittelgruppen „0/0“ und „0/1“ werden angezeigt. Wenn dann auf die Mittelgruppe „0/0“ geklickt wird, wird der Datenpunkt „0/0/1“ angezeigt. Die Gruppen werden automatisch angelegt, wenn die Datenpunkte hinzugefügt werden.

Mit einem Klick auf Datenpunkt hinzufügen öffnet sich ein Popup, in dem der Haupt-, optional der Unterdatentyp und die Gruppenadresse für den neuen Datenpunkt ausgewählt werden kann. Dieser wird dann mit Klick auf Hinzufügen erstellt.

Bedienung

Im Operator Panel des Moduls unter Hardware – techCOM Linie werden folgende Informationen und Funktionen bereitgestellt:

  • Der aktuelle Status des Treibers wird angezeigt.
  • Ein Button zum Neustarten des Treibers steht zur Verfügung.
  • Über den Button Bearbeiten kann zur Konfiguration der einzelnen Datenpunkte gewechselt werden.
  • Ein Button zum Löschen aller Datenpunkte steht zur Verfügung.
  • Über den Button Importieren kann ein bestehendes KNX-Projekt importiert werden. Wichtig: Beim Export des KNX-Projekts in der ETS muss der Dateityp „Turtle-Datei Export (ttl)“ ausgewählt werden!
  • Die zuletzt empfangenen Telegramme werden angezeigt.

Allgemeine Einstellungen der Blöcke

Allgemein können für die Blöcke folgende Einstellungen vorgenommen werden:

  • Gruppenadresse: Hier muss definiert werden, auf welcher KNX-Adresse dieser Datenpunkt zugewiesen ist.
  • Hauptdatentyp: Hier kann der Hauptdatentyp des KNX Datenpunkts geändert werden.
  • Hat Unterdatentyp: Ob der KNX Datenpunkt einen Unterdatentyp hat. Wenn diese Option aktiviert, kann der Typ unterhalb gewählt werden.
  • Unterdatentyp: Hier kann der Unterdatentyp des KNX Datenpunkts geändert werden.
  • Lesen: Ob der KNX Datenpunkt einmalig nach dem Hinzufügen oder dem Neustart des Systems den Wert des Datenpunkts abfragen soll
  • Zyklisches Lesen: Ob zyklisch gelesen werden soll. Wenn diese Option aktiviert ist kann unterhalb eine Zeit eingestellt werden
  • Schreiben: Ob die Werte des KNX Datenpunkt geändert werden und dann auf den Bus geschrieben werden. Wenn unterhalb nicht anders eingestellt, passiert das nach jeder Wertänderung.
  • Auf Wertänderung schreiben: (nur bei Datenpunkt 10.x Zeit verfügbar) Ob bei Wertänderung diese neuen Werte als Telegram auf den KNX Bus geschrieben werden sollen. Wenn diese Option nicht verfügbar ist, werden die Telegramme immer bei Wertänderung auf den KNX Bus geschrieben.
  • Zyklisches Schreiben: Ob zyklisch geschrieben werden soll. Wenn diese Option aktiviert ist kann unterhalb eine Zeit eingestellt werden

Erweiterte Einstellungen

Wenn man im Parameter Panel auf Erweiterte Parameter klickt, werden die zuletzt erhaltenen oder empfangenen Telegramme des Datenpunkts angezeigt

Boolscher Datenpunkt

Der boolsche Datenpunkt umfasst folgende Datentypen:

  • DPT 1.*
  • DPT 2.* 1-Bit Gesteuert
  • DPT 21.* 8-Bit Feld
  • DPT 27.* 32-Bit Feld
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Status des ausgewählten Bits wird angezeigt und kann wenn Schreiben aktiviert ist umgeschalten werden
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Status des ausgewählten Bits wird angezeigt und kann wenn Schreiben aktiviert ist umgeschalten werden
  • Letzter Datenempfang wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Einstellungen für die einzelnen Bits:

  • Invertieren: Hier kann der Wert invertiert werden
  • Nur auf Wertänderung reagieren: Wenn diese Option aktiviert ist, werden die Events für dieses Bit nur ausgelöst, wenn sich der Wert geändert hat. Ansonsten wird bei jedem Datenerhalt das entsprechende Event ausgelöst.
  • Aliase: (können nur geändert werden, wenn die Option „Hat Unterdatentyp“ nicht aktiviert ist) Für das Bit selbst, sowie für den Wert 0 und 1 kann ein Alias vergeben werden. Wenn für den Wert 0 und 1 kein Alias vergeben ist, wird automatisch Aus und Ein in Object sowie Operator Panel angezeigt
Verlinkungen

Verlinkungen:

  • Steigende Flanke: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn für das jeweilige Bit der Wert 1 erhalten wird. Hierbei ist jedoch die Option Nur auf Wertänderung reagieren zu beachten.
  • Fallende Flanke: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn für das jeweilige Bit der Wert 0 erhalten wird. Hierbei ist jedoch die Option Nur auf Wertänderung reagieren zu beachten.
  • Empfangener Wert: Hier können mehrere Properties ausgewählt werden, welche mit dem empfangenen Wert des jeweiligen Bits beschrieben werden. Hierbei ist jedoch die Option Nur auf Wertänderung reagieren zu beachten.
  • Schreibender Wert: Wenn Schreiben ausgewählt ist, kann hier ein Property ausgewählt werden, welches falls die Option Zyklisches Schreiben aktiviert ist zyklisch und ansonsten bei Wertänderung auf den KNX-Bus geschrieben wird.
Szenen

Vom boolschen Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Steigende Flanke: Siehe Verlinkungen
  • Fallende Flanke: Siehe Verlinkungen

Vom boolschen Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Wert setzen: Wenn Schreiben ausgewählt ist, kann hierüber ein Bit ausgewählt werden, welches mit mit einem bestimmten Wert beschrieben wird. Wenn die Szene ausgelöst wird jedes Mal ein Telegramm auf den KNX-Bus gesendet. ACHTUNG: Wenn dieses Bit bereits von der Logik geschrieben wird, wird es wieder von dieser überschrieben!
Logik

Vom boolschen Datenpunkt werden folgende Möglichkeiten für die Verwendung in Logiken bereitgestellt:

  • Fehler (lesen)
  • Letzter Datenempfang (lesen)
  • Bit x (lesen und schreiben): Das lesende Property ist immer sichtbar, das schreibende ist sichtbar wenn die Option Schreiben aktiviert ist

Stufen Datenpunkt

Der Stufen Datenpunkt entspricht folgenden Datentyp:

  • DPT 3.* 3-Bit Gesteuert
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Status wird angezeigt (Stopp oder Richtung und Stufen/Intervalle/Prozent (je nach Einstellung))
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Status wird angezeigt (Richtung und gegebenenfalls Stufen/Intervalle/Prozent (je nach Einstellung))
  • Letzter Datenempfang wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Einstellungen:

  • Auswertung des Step-Code (Prozent, Intervalle, Stufen)
Verlinkungen

Verlinkungen:

  • Wert wurde erhöht: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn der Wert des Datenpunkts erhöht wurde
  • Wert wurde verringert: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn der Wert des Datenpunkts verringert wurde
  • Wurde gestoppt: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn der Status des Bausteins auf „Stopp“ gewechselt hat
  • Empfangener Wert (Control): Hier kann ein Property ausgewählt werden, auf welches der Wert des Control-Properties geschrieben wird
  • Empfangener Wert (Prozent/Intervalle/Stufen): Hier kann ein Property ausgewählt werden, auf welchen der Wert der empfangene entsprechende Wert des Bausteins geschrieben wird.
  • Empfangener Wert (Control): Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Control-Property des Datenpunkts schreibt
  • Empfangener Wert (Prozent/Intervalle/Stufen): Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf den entsprechenden Wert des Datenpunkts schreibt
Szenen

Vom Stufen Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Wert wurde erhöht
  • Wert wurde verringert
  • Wurde gestoppt

Vom Stufen Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Wert setzen: Hier kann je nach der gewählten Einstellung im Parameter Panel, der Prozent-, Intervall- oder Stufen-Wert gesetzt werden. Wenn diese Szene ausgelöst wird, wird der Wert auf den KNX-Bus geschrieben, egal ob der Wert sich verändert hat oder im Datenpunkt gleich geblieben ist
Logik

Vom Stufen Datenpunkt werden folgende Möglichkeiten für die Verwendung Logiken bereitgestellt:

  • Control (lesen und schreiben): Das lesende Property ist immer sichtbar, das schreibende ist sichtbar wenn die Option Schreiben aktiviert ist
  • Stufen (lesen und schreiben): Das lesende Property ist immer sichtbar, das schreibende ist sichtbar wenn die Option Schreiben aktiviert ist
  • Fehler (lesen)
  • Letzter Datenempfang (lesen)

Text Datenpunkt

Der Text Datenpunkt umfasst folgende Datentypen:

  • DPT 4.* Zeichen
  • DPT 16.* Zeichen
  • DPT 24.* Variable Länge ISO-8859-1 String
  • DPT 28.* Unicode UTF-8 String
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Text wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Text wird angezeigt und kann - wenn Schreiben aktiviert ist - geändert werden
  • Letzter Datenempfang wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Einstellungen:

  • Nur auf Wertänderung reagieren: Wenn diese Option aktiviert ist, wird das Event Neuer Wert wurde empfangen nur ausgelöst, wenn ein anderer Wert als zuvor empfangen wird. Andersfalls wird das Event bei jedem Datenempfang ausgelöst.
  • Codierung: Wenn als Hauptdatentyp DPT 4.x Zeichen oder DPT 16.x Zeichen ausgewählt und kein Unterdatentyp vorhanden ist, dann muss gewählt werden, ob der Text via ASCII oder ISO 8859-1 codiert ist.
Verlinkungen
  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird. Dabei ist die Option Nur auf Wertänderung reagieren zu beachten
  • Empfangener Text: Hier können mehrere Properties ausgewählt werden, welche mit dem empfangenen Text beschrieben werden. Hierbei ist jedoch die Option Nur auf Wertänderung reagieren zu beachten.
  • Schreibender Text: Wenn Schreiben ausgewählt ist, kann hier ein Property ausgewählt werden, welches - falls die Option Zyklisches Schreiben aktiviert ist - zyklisch und ansonsten bei Wertänderung auf den KNX-Bus geschrieben wird.
Szenen

Vom Text Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird

Vom Text Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Text setzen: Wenn Schreiben ausgewählt ist, kann hierüber ein Text gesendet werden. Wenn die Szene ausgelöst wird jedes Mal ein Telegramm auf den KNX-Bus gesendet.
Logik
  • Fehler (lesen)
  • Letzter Datenempfang (lesen)
  • Text (lesen und schreiben): Das lesende Property ist immer sichtbar, das schreibende ist sichtbar, wenn die Option Schreiben aktiviert ist

Nummerischer Datenpunkt

Der Text Datenpunkt umfasst folgende Datentypen:

  • DPT 5.* 8-Bit vorzeichenlos
  • DPT 6.* 8-Bit vorzeichenbehaftet
  • DPT 7.* 2-Byte vorzeichenlos
  • DPT 8.* 2-Byte vorzeichenbehaftet
  • DPT 9.* 2-Byte Gleitkommawert
  • DPT 12.* 4-Byte vorzeichenlos
  • DPT 13.* 4-Byte vorzeichenbehaftet
  • DPT 14.* 4-Byte Gleitkommawert
  • DPT 29.* Elektrische Energie
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Status wird angezeigt
  • Wert wird angezeigt und kann - wenn die Option Schreiben aktiviert ist - geändert werden
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Wert wird angezeigt und kann - wenn die Option Schreiben aktiviert ist - geändert werden
  • Letzter Datenempfang wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Einstellungen:

  • Nur auf Wertänderung reagieren: Wenn diese Option aktiviert ist, wird das Event Neuer Wert wurde empfangen nur ausgelöst, wenn ein anderer Wert als zuvor empfangen wird. Andersfalls wird das Event bei jedem Datenempfang ausgelöst.

Skalierung:

  • Minimum: Wird vom Unterdatentyp bestimmt, oder kann geändert werden wenn kein Unterdatentyp vorhanden ist.
  • Maximum: Wird vom Unterdatentyp bestimmt, oder kann geändert werden wenn kein Unterdatentyp vorhanden ist.
  • Schrittweite: Wird vom Unterdatentyp bestimmt, oder kann geändert werden wenn kein Unterdatentyp vorhanden ist.

Anzeigeeinstellungen:

  • Einheit: Hier kann die Einheit festgelegt werden.
  • Multiplikator: Empfangene Werte werden dividiert und geschriebene multipliziert gesendet.
Verlinkungen
  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird. Dabei ist die Option Nur auf Wertänderung reagieren zu beachten
  • Empfangener Wert: Hier können mehrere Properties ausgewählt werden, welche mit dem empfangenen Wert beschrieben werden. Hierbei ist jedoch die Option Nur auf Wertänderung reagieren zu beachten.
  • Schreibender Wert: Wenn Schreiben ausgewählt ist, kann hier ein Property ausgewählt werden, welches falls die Option Zyklisches Schreiben aktiviert ist zyklisch und ansonsten bei Wertänderung auf den KNX-Bus geschrieben wird.
Szenen

Vom Nummern Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird

Vom Nummern Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Text setzen: Wenn Schreiben ausgewählt ist, kann hierüber ein numerischer Wert gesendet werden. Wenn die Szene ausgelöst wird jedes Mal ein Telegramm auf den KNX-Bus gesendet.
Logik
  • Fehler (lesen)
  • Letzter Datenempfang (lesen)
  • Wert (lesen und schreiben): Das lesende Property ist immer sichtbar, das schreibende ist sichtbar wenn die Option Schreiben aktiviert ist

Modus Datenpunkt

Der Modus Datenpunkt umfasst folgenden Datentyp:

  • DPT 6.020 Status mit Modus
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Ausgewählter Anzeigewert wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Letzter Datenempfang wird angezeigt
  • Werte werden angezeigt und können - wenn die Option Schreiben aktiviert ist - geändert werden
  • Im Fehlerfall wird dieser angezeigt

Einstellungen:

  • Anzeigewert: Der hier ausgewählte Wert, wird im Object Panel als Status angezeigt
  • Invertierung: Wenn die Option aktiviert ist, werden die Werte des entsprechenden Status invertiert
  • Nur auf Wertänderung reagieren: Wenn diese Option aktiviert ist, werden alle Events des jeweiligen Status oder des Modus nur ausgelöst, wenn ein anderer Wert als zuvor empfangen wird. Andersfalls wird das Event bei jedem Datenempfang ausgelöst.
Verlinkungen
  • Neuer Wert wurde empfangen: Die ausgewählte Methode wird bei neu empfangenem Wert ausgelöst.
    Für jeden Status gibt es folgende Verlinkungen:
  • Steigende Flanke: Die ausgewählte Methode wird bei steigender Flanke des jeweiligen Status ausgelöst.
  • Fallende Flanke: Die ausgewählte Methode wird bei fallender Flanke des jeweiligen Status ausgelöst.

Für jeden Status und für den aktiven Modus gibt es folgende Verlinkungen:

  • Empfangener Wert: Der ausgewählte Wert wird bei empfangenem Wert beschrieben.
  • Schreibender Wert: Der ausgewählte Wert wird geschrieben.

Die Option Nur auf Wertänderung reagieren ist zu beachten.

Szenen

Vom Modus Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Neuer Wert wurde empfangen
    Für jeden Status:
  • Fallende Flanke
  • Steigende Flanke

Vom Modus Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Wert setzen: Wenn Schreiben ausgewählt ist, kann hierüber der Modus gesendet werden. Wenn die Szene ausgelöst wird jedes Mal ein Telegramm auf den KNX-Bus gesendet.
Logik

Vom Modus Datenpunkt werden folgende Möglichkeiten für die Verwendung in Logiken bereitgestellt:

  • Fehler (lesen)
  • Status A (lesen und schreiben)
  • Status B (lesen und schreiben)
  • Status C (lesen und schreiben)
  • Status D (lesen und schreiben)
  • Status E (lesen und schreiben)
  • Aktiver Modus (lesen und schreiben)

Zeit Datenpunkt

Der Zeit Datenpunkt entspricht folgenden Datentyp:

  • DPT 10.* Zeit
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Tag und Uhrzeit wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Tag und Uhrzeit wird angezeigt und kann - wenn Schreiben aktiviert ist - geändert werden
  • Letzter Datenempfang wird angezeigt
  • Im Fehlerfall wird dieser angezeigt
Verlinkungen
  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird. Dabei ist die Option Nur auf Wertänderung reagieren zu beachten
  • Empfangener Wert Tag: Hier können mehrere Properties ausgewählt werden, auf welche der vom KNX-Bus empfangene Wert für den Tag geschrieben werden soll.
  • Empfangener Wert Stunde: Hier können mehrere Properties ausgewählt werden, auf welche der vom KNX-Bus empfangene Wert für den Stunde geschrieben werden soll.
  • Empfangener Wert Minute: Hier können mehrere Properties ausgewählt werden, auf welche der vom KNX-Bus empfangene Wert für den Minute geschrieben werden soll.
  • Empfangener Wert Sekunde: Hier können mehrere Properties ausgewählt werden, auf welche der vom KNX-Bus empfangene Wert für den Sekunde geschrieben werden soll.
  • Schreibender Wert Tag: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Property Tag des Datenpunkts schreibt.
  • Schreibender Wert Stunde: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Property Stunde des Datenpunkts schreibt.
  • Schreibender Wert Minute: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Property Minute des Datenpunkts schreibt.
  • Schreibender Wert Sekunde: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Property Sekunde des Datenpunkts schreibt.
Szenen

Vom Zeit Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird.

Vom Zeit Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Wert setzen: Hier kann der Tag und die Uhrzeit gesetzt werden. Wenn diese Szene ausgelöst wird, wird der Wert auf den KNX-Bus geschrieben, unabhängig davon ob der Wert sich verändert hat oder im Datenpunkt gleich geblieben ist.
Logik
  • Fehler (lesen)
  • Zuletzt Daten empfangen (lesen)
  • Tag (lesen und schreiben): 0 = Kein Tag, 1 = Montag, ... 7 = Sonntag
  • Stunde (lesen und schreiben)
  • Minute (lesen und schreiben)
  • Sekunde (lesen und schreiben)

ACHTUNG: Die lesenden Properties sind immer sichtbar, die schreibenden sind nur sichtbar wenn die Option Schreiben aktiviert ist.

Datum Datenpunkt

Der Datum Datenpunkt entspricht folgenden Datentyp:

  • DPT 11.* Datum
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Datum wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Im Fehlerfall wird dieser angezeigt
  • Letzter Datenempfang wird angezeigt
  • Hier wird das Datum angezeigt oder kann - wenn die Option Schreiben im Parameter Panel ausgewählt ist - geändert werden
Verlinkungen
  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird
  • Empfangener Wert Tag: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für den Tag geschrieben werden soll.
  • Empfangener Wert Monat: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für den Monat geschrieben werden soll.
  • Empfangener Wert Jahr: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für das Jahr geschrieben werden soll.
  • Schreibender Wert Tag: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Tag Property des Datenpunkts schreibt
  • Schreibender Wert Monat: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Monat Property des Datenpunkts schreibt
  • Schreibender Wert Jahr: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Jahr Property des Datenpunkts schreibt
Szenen

Vom Datum Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird

Vom Datum Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Wert setzen: Hier kann das Datum gesetzt werden. Wenn diese Szene ausgelöst wird, wird der Wert auf den KNX-Bus geschrieben, unabhängig davon ob der Wert sich verändert hat oder im Datenpunkt gleich geblieben ist.
Logik

Logik:

  • Fehler (lesen)
  • Zuletzt Daten empfangen (lesen)
  • Tag (lesen und schreiben)
  • Monat (lesen und schreiben)
  • Jahr (lesen und schreiben)

ACHTUNG: Die lesenden Properties sind immer sichtbar, die schreibenden sind nur sichtbar wenn die Option Schreiben aktiviert ist.

Zutritt Datenpunkt

Der Zutritt Datenpunkt entspricht folgenden Datentyp:

  • DPT 15.* Zutritt
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Status wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Letzter Datenempfang wird angezeigt
  • Werte werden angezeigt und können - wenn die Option Schreiben aktiviert ist - geändert werden
  • Im Fehlerfall wird dieser angezeigt

Einstellungen:

  • Nur auf Wertänderung reagieren: Wenn diese Option aktiviert ist, wird das Event Neuer Wert wurde empfangen nur ausgelöst, wenn ein anderer Wert als zuvor empfangen wird. Andersfalls wird das Event bei jedem Datenempfang ausgelöst.
Verlinkungen
  • Zutritt wurde gewährt: Die ausgewählte Methode wird bei einem gewährten Zutrittsversuch ausgelöst.
  • Zutritt wurde verweigert: Die ausgewählte Methode wird bei einem verweigerten Zutrittsversuch ausgelöst
  • Fehlerhafter Zutritt erkannt: Die ausgewählte Methode wird bei einem verweigerten Zutrittsversuch ausgelöst.
  • Empfangener Wert Code: Der ausgewählte Wert wird bei einem Zutrittsversuch mit dem erhaltenen Wert beschrieben.
  • Empfangener Wert Fehlerhafter Zutritt: Der ausgewählte Wert wird bei einem fehlerhaften Zutrittsversuch mit dem erhaltenen Wert beschrieben.
  • Empfangener Wert Zutritt gewährt/verweigert: Der ausgewählte Wert wird bei einem erfogreichen oder verweigerten Zutrittsversuch mit dem erhaltenen Wert beschrieben.
  • Empfangener Wert Leserichtung: Der ausgewählte Wert wird bei einem Zutrittsversuch mit dem erhaltenen Wert der Leserichtung beschrieben.
  • Empfangener Wert Verschlüsselung: Der ausgewählte Wert wird bei einem Zutrittsversuch mit dem erhaltenen Wert der Verschlüsselung beschrieben.
  • Empfangener Wert Index: Der ausgewählte Wert wird bei einem Zutrittsversuch mit dem erhaltenen Wert des Index beschrieben.
  • Schreibender Wert Code: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Property Code des Datenpunkts schreibt.
  • Schreibender Wert Fehlerhafter Zutritt: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Property Fehlerhafter Zutritt des Datenpunkts schreibt.
  • Schreibender Wert Zutritt gewährt/verweigert: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Property Zutritt gewährt/verweigert des Datenpunkts schreibt.
  • Schreibender Wert Leserichtung: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Property Leserichtung des Datenpunkts schreibt.
  • Schreibender Wert Verschlüsselung: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Property Verschlüsselung des Datenpunkts schreibt.
  • Schreibender Wert Index: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Property Index des Datenpunkts schreibt.

Die Option Nur auf Wertänderung reagieren ist zu beachten.

Szenen

Vom Zutritt Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Fehlerhaften Zutritt erkannt
  • Zutritt wurde gewährt
  • Zutritt wurde verweigert

Vom Zutritt Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Zugriff senden: Wenn Schreiben ausgewählt ist, kann hierüber eine Zugriffsanfrage gesendet werden. Wenn die Szene ausgelöst wird jedes Mal ein Telegramm auf den KNX-Bus gesendet.
Logik

Vom Zutritt Datenpunkt werden folgende Möglichkeiten für die Verwendung in Logiken bereitgestellt:

  • Fehler (lesen)
  • Fehlerhafter Zutritt (lesen)
  • Leserichtung (lesen)
  • Verschlüsselung (lesen)
  • Zutritt gewährt/verweigert (lesen)

Szenen Datenpunkt

Der Szenen Datenpunkt umfasst folgende Datentypen:

  • DPT 17.* Szenen Nummer
  • DPT 18.* Szenensteuerung
  • DPT 26.* 8-Bit Feld
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Szenennummer wird angezeigt und kann - wenn die Option Schreiben im Parameter Panel ausgewählt ist - gesendet werden
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Im Fehlerfall wird dieser angezeigt
  • Letzter Datenempfang wird angezeigt
  • Szenennummer wird angezeigt oder kann - wenn die Option Schreiben im Parameter Panel ausgewählt ist - geändert werden
  • Wenn die Option Schreiben ausgewählt ist, kann die Szenennummer je nach DPT, mit verschiedenen Funktionen an den KNX-Bus gesendet werden
Verlinkungen
  • Zusätzliche Verlinkung hinzufügen: Hier können zusätzliche Verlinkungen für einzelne Szenennummer hinzugefügt werden.
  • Szene wurde ausgelöst (nur DPT 16. und 17.): Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn eine beliebige Szene ausgelöst wurde. Wenn eine zusätzliche Verlinkung z.B. Szene 1 wurde ausgelöst hinzugefügt wurde und die Methode hierüber ausgewählt wurde, wird diese nur ausgelöst, wenn die entsprechende Szene aktiviert wurde.
  • Szene wurde eingelernt (nur DPT 17.*): Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn eine beliebige Szene eingelernt wurde. Wenn eine zusätzliche Verlinkung z.B. Szene 1 wurde eingelernt hinzugefügt wurde und die Methode hierüber ausgewählt wurde, wird diese nur ausgelöst, wenn die entsprechende Szene eingelernt wurde.
  • Szene wurde aktiviert (nur DPT 26.*): Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn eine beliebige Szene aktiviert wurde. Wenn eine zusätzliche Verlinkung z.B. Szene 1 wurde aktiviert hinzugefügt wurde und die Methode hierüber ausgewählt wurde, wird diese nur ausgelöst, wenn die entsprechende Szene aktiviert wurde.
  • Szene wurde deaktiviert (nur DPT 26.*): Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn eine beliebige Szene deaktiviert wurde. Wenn eine zusätzliche Verlinkung z.B. Szene 1 wurde deaktiviert hinzugefügt wurde und die Methode hierüber ausgewählt wurde, wird diese nur ausgelöst, wenn die entsprechende Szene deaktiviert wurde.
  • Zuletzt erhaltene Szene: Hier können mehrere Properties ausgewählt werden, welche mit der zuletzt erhaltenen Szenennummer beschrieben werden.
  • Szene schreiben: Wenn Schreiben ausgewählt ist, kann für die Szenennummer ein Property ausgewählt werden, welches - falls die Option Zyklisches Schreiben aktiviert ist - zyklisch und ansonsten bei Wertänderung auf den KNX-Bus geschrieben wird. Bei den DPTs 16. und 17. wird hierbei die Szenennummer mit der zuletzt geschriebenen Funktion gesendet. Wenn also zuletzt eine Szenen aktiviert wurde, wird die verknüpfte Szenennummer zyklisch aktiviert.
Szenen

Vom Szenen Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Szene wurde ausgelöst (bei DPT 17. und DPT 18.)
  • Szene wurde eingelernt (bei DPT 18.*)
  • Szene wurde aktiviert (bei DPT 26.*)
  • Szene wurde deaktiviert (bei DPT 26.*)

Vom Text Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Szene auslösen (bei DPT 17. und DPT 18.): Hier kann gewählt werden, welche KNX-Szene ausgelöst werden soll.
  • Szene einlernen (bei DPT 18.*): Hier kann gewählt werden, welche KNX-Szene eingelernt werden soll.
  • Szene aktivieren (bei DPT 26.*): Hier kann gewählt werden, welche KNX-Szene aktiviert werden soll.
  • Szene deaktivieren (bei DPT 26.*): Hier kann gewählt werden, welche KNX-Szene deaktiviert werden soll.

ACHTUNG: Wenn eine Funktion des Szenen Datenpunkts ausgelöst wird, wird der Wert auf den KNX-Bus geschrieben, unabhängig davon ob der Wert sich verändert hat oder im Datenpunkt gleich geblieben ist.

Logik
  • Fehler (lesen)
  • Zuletzt Daten empfangen (lesen)
  • Szenennummer (nur bei DPT 17.*, lesen und schreiben): Das lesende Property ist immer sichtbar, das schreibende ist sichtbar, wenn die Option Schreiben aktiviert ist
  • Lern Bit (nur bei DPT 18.*, lesen und schreiben): Das lesende Property ist immer sichtbar, das schreibende ist sichtbar, wenn die Option Schreiben aktiviert ist
  • Aktiv Bit (nur bei DPT 26.*, lesen und schreiben): Das lesende Property ist immer sichtbar, das schreibende ist sichtbar, wenn die Option Schreiben aktiviert ist

Datum und Uhrzeit Datenpunkt

Der Datum und Uhrzeit Datenpunkt entspricht folgenden Datentyp:

  • DPT 19.* Datum und Uhrzeit
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Tag, Datum, Uhrzeit und Zeitzone wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Im Fehlerfall wird dieser angezeigt
  • Letzter Datenempfang wird angezeigt
  • Hier wird der Tag, das Datum, die Uhrzeit und Zeitzone angezeigt oder kann, wenn die Option Schreiben im Parameter Panel ausgewählt ist, geändert werden. Zudem können auch die erweiterten Einstellungen geändert werden.
Verlinkungen

Verlinkungen:

  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird
  • Empfangener Wert Jahr: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für das Jahr geschrieben werden soll.
  • Empfangener Wert Kein Jahr: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für Kein Jahr geschrieben werden soll. Dieser Wert ist true wenn kein Jahr in den Daten erhalten ist.
  • Empfangener Wert Monat: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für den Tag des Monats geschrieben werden soll.
  • Empfangener Wert Tag des Monats: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für das Tag des Monats geschrieben werden soll.
  • Empfangener Wert Kein Datum: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für Kein Datum geschrieben werden soll. Dieser Wert ist true wenn kein Datum in den Daten erhalten ist.
  • Empfangener Wert Stunde: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für die Stunde geschrieben werden soll.
  • Empfangener Wert Minuten: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für die Minuten geschrieben werden soll.
  • Empfangener Wert Sekunden: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für die Sekunden geschrieben werden soll.
  • Empfangener Wert Keine Zeit: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für Keine Zeit geschrieben werden soll. Dieser Wert ist true wenn keine Zeit in den Daten erhalten ist.
  • Empfangener Wert Tag der Woche: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für das Tag der Woche geschrieben werden soll.
  • Empfangener Wert Kein Wochentag: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für Kein Wochentag geschrieben werden soll. Dieser Wert ist true wenn kein Wochentag in den Daten erhalten ist.
  • Empfangener Wert Arbeitstag: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für Arbeitstag geschrieben werden soll. Dieser Wert ist true wenn der erhaltene Tag ein Arbeitstag ist.
  • Empfangener Wert Wochentag Feld nicht gültig: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für Wochentag Feld nicht gültig geschrieben werden soll. Dieser Wert ist true wenn das Wochentag Feld nicht ausgewertet werden soll.
  • Empfangener Wert Standard Sommerzeit: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für die Standard Sommerzeit geschrieben werden soll. Dieser Wert ist true wenn die Standard Sommerzeit eingestellt ist.
  • Empfangener Wert Uhr mit extern synchronisiertem Signal: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für die Uhr mit extern synchronisiertem Signal geschrieben werden soll.
  • Empfangener Wert Fehler: Hier kann ein Property ausgewählt werden, auf welches der vom KNX-Bus empfangene Wert für die Fehler geschrieben werden soll. Dieser Wert ist true wenn ein interner Fehler auftritt.
  • Schreibender Wert Jahr: Hier kann ein Property ausgewählt werden, welches einmalig nach dem Verknüpfen und bei einer Wertänderung des Properties, den jeweiligen Wert auf das Jahr-Property des Datenpunkts schreibt. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Kein Jahr: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Monat: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Tag des Monats: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Kein Datum: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Stunde: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Minuten: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Sekunden: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Keine Zeit: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Tag der Woche: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Kein Wochentag: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Arbeitstag: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Wochentag Feld nicht gültig: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Standard Sommerzeit: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Uhr mit extern synchronisiertem Signal: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
  • Schreibender Wert Fehler: Gleiches Verhalten wie bei Schreibender Wert Jahr, nur das es auf das entsprechende Property geschrieben wird. Für das genau Verhalten bei Änderung des Properties, bitte die Informationen bei der Beschreibung des lesenden Verlinkung lesen.
Szenen

Vom Uhrzeit und Zeit Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird

Vom Uhrzeit und Zeit Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Wert setzen: Hier kann der Tag und die Uhrzeit gesetzt werden. Wenn diese Szene ausgelöst wird, wird der Wert auf den KNX-Bus geschrieben, unabhängig davon ob der Wert sich verändert hat oder im Datenpunkt gleich geblieben ist.
Logik

Logik:

  • Arbeitstag (lesen und schreiben)
  • Fehler (lesen)
  • Fehler erhalten (lesen und schreiben): Interner Fehler
  • Jahr (lesen und schreiben)
  • Kein Datum (lesen und schreiben)
  • Kein Jahr (lesen und schreiben)
  • Kein Wochentag (lesen und schreiben)
  • Keine Zeit (lesen und schreiben)
  • Minuten (lesen und schreiben)
  • Monat (lesen und schreiben)
  • Sekunden (lesen und schreiben)
  • Stunde (lesen und schreiben)
  • Standard Sommerzeit (lesen und schreiben)
  • Tag der Woche (lesen und schreiben)
  • Tag des Monats (lesen und schreiben)
  • Uhr mit extern synchronisiertem Signal (lesen und schreiben)
  • Wochentag Feld nicht gültig (lesen und schreiben)
  • Zuletzt Daten empfangen (lesen)

ACHTUNG: Die lesenden Properties sind immer sichtbar, die schreibenden sind nur sichtbar wenn die Option Schreiben aktiviert ist.

Optionen Datenpunkt

Der Optionen Datenpunkt umfasst folgende Datentypen:

  • DPT 20.* 1-Byte
  • DPT 23.* 2-Bit Feld
Bedienung

Object Panel:

  • Name und Gruppenadresse wird angezeigt
  • Option wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Operator Panel:

  • Name und Gruppenadresse wird angezeigt
  • Option wird angezeigt und kann - wenn Schreiben aktiviert ist - geändert werden
  • Letzter Datenempfang wird angezeigt
  • Im Fehlerfall wird dieser angezeigt

Einstellungen:

  • Nur auf Wertänderung reagieren: Wenn diese Option aktiviert ist, wird das Event Neuer Wert wurde empfangen nur ausgelöst, wenn ein anderer Wert als zuvor empfangen wird. Andersfalls wird das Event bei jedem Datenempfang ausgelöst.
  • Werte benennen: Wenn kein Unterdatentyp gewählt ist, können die Werte selbst hinzugefügt werden. Andernfalls sind diese vorgegeben.
Verlinkungen
  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird. Dabei ist die Option Nur auf Wertänderung reagieren zu beachten
  • Empfangener Wert: Hier können mehrere Properties ausgewählt werden, welche mit dem empfangenen Wert beschrieben werden. Hierbei ist jedoch die Option Nur auf Wertänderung reagieren zu beachten.
  • Schreibender Wert: Wenn Schreiben ausgewählt ist, kann hier ein Property ausgewählt werden, welches - falls die Option Zyklisches Schreiben aktiviert ist - zyklisch und ansonsten bei Wertänderung auf den KNX-Bus geschrieben wird.
Szenen

Vom Optionen Datenpunkt werden folgende Auslöser für Szenen (wenn ...) bereitgestellt:

  • Neuer Wert wurde empfangen: Hier kann eine Methode ausgewählt werden, welche ausgelöst werden soll, wenn ein neuer Wert vom KNX-Bus empfangen wird.

Vom Optionen Datenpunkt werden folgende Funktionen für Szenen (dann ...) bereitgestellt:

  • Text setzen: Wenn Schreiben ausgewählt ist, kann hierüber eine Option gesendet werden. Wenn die Szene ausgelöst wird jedes Mal ein Telegramm auf den KNX-Bus gesendet.
Logik
  • Fehler (lesen)
  • Zuletzt Daten empfangen (lesen)
  • Wert (lesen und schreiben): Das lesende Property ist immer sichtbar, das schreibende ist sichtbar, wenn die Option Schreiben aktiviert ist

Lüfter

Durch die Umwandlung von digitalen Ausgängen zu Lüfter können diese beispielsweise für die Ansteuerung von WC Lüfter verwendet werdenDiese Lüfter reagieren automatisch auf Lichter desselben Raums oder optional auf Taster oder Bewegungsmelder.

Sie finden die Lüfter unter „Alle Apps“ – „Lüftung“

Konfiguration

Um einen Lüfter zu erstellen können Sie einen beliebigen digitalen Ausgang verwenden. Öffnen Sie dazu das Operator Panel des gewünschten digitalen Ausgangs und ändern Sie den Typ auf „Lüfter“. Der digitale Ausgang wird automatisch zu einem Lüfter umgewandelt und ist unter Lüftung zu finden.

Durch das Auswählen eines Raumes werden automatisch alle im Raum befindlichen Lichter mit der Lüftung verknüpft. Sie haben jedoch jederzeit die Möglichkeit, Lichter zu entfernen oder hinzuzufügen. Zusätzlich haben Sie die Möglichkeit, Bewegungsmelder und Taster zu verknüpfen.

Einschaltverzögerung:
Beim Einschalten des ersten verknüpften Lichtes, bzw. der ersten Betätigung eines verknüpften Tasters oder der ersten Aktivierung eines verknüpften Bewegungsmelders wird die Einschaltverzögerung aktiviert. Nach Ablauf der Einschaltverzögerung wird der Lüfter eingeschaltet.

Ausschaltverzögerung:
Nach dem Ausschalten des letzten verknüpften Lichtes, bzw. der nach der letzten Betätigung eines verknüpften Tasters oder der Deaktivierung des letzten Bewegungsmelders wird die Ausschaltverzögerung aktiviert. Nach Ablauf der Ausschaltverzögerung wird der Lüfter ausgeschaltet.

Bedienung

Im Operator Panel sowie im Object Panel haben Sie die Möglichkeit, den Lüfter zu steuern.

Durch das manuelle Einschalten des Lüfters wird der Lüfter sofort eingeschaltet und die Ausschaltverzögerung aktiviert. Nach Ablauf der Ausschaltverzögerung wird der Lüfter wieder ausgeschaltet.

Durch erneutes Einschalten des Lüfters, während die Ausschaltverzögerung aktiv ist, wird die Ausschaltverzögerung wieder zurückgesetzt.

Durch das manuelle Ausschalten wird der Lüfter sofort ausgeschaltet.

Szenen

Der Lüfter bietet folgende Funktionen für Szenen (dann ...):

  • Einschalten: Der Lüfter wird eingeschaltet
  • Ausschalten: Der Lüfter wird ausgeschaltet
  • Verzögert einschalten: Die Einschaltverzögerung wird aktiviert und der Lüfter nach dessen Ablauf eingeschaltet
  • Verzögert ausschalten: Die Ausschaltverzögerung wird aktiviert und der Lüfter nach dessen Ablauf ausgeschaltet

KWB

Mit der App „KWB Comfort Smart“ können Sie Ihre KWB Comfort C3 Heizungssteuerung integrieren.

Sie finden die KWB Anwendung unter „Alle Apps“ – „Comfort Smart“.

Erstellen

Für die Verbindung einer KWB Heizungssteuerung mit dem Smart Building Automation System muss diese mit dem Gebäudenetzwerk verbunden sein und über eine gültige Netzwerkkonfiguration verfügen. Nach dem Hinzufügen einer neuen Anlage muss die IP-Adresse der Heizungssteuerung unter den Verbindungseinstellungen eingetragen werden. Eine erfolgreiche Kommunikation mit der Steuerung wird über den Verbindungsstatus angezeigt.

Bedienen

Die Comfort-Smart App dient hauptsächlich zur Anzeige des aktuellen Status und zur Konfiguration der Buffertemperaturen. Über das Operator-Panel kann jedoch auch die Anlage gesamt Ein- oder Ausgeschaltet werden.

Szenen

Das Comfort Smart App bietet folgende Funktionen für Szenen (dann ...):

Einschalten: Die gesamte Anlage wird eingeschaltet
Ausschalten: Die gesamte Anlage wird ausgeschaltet

Ladestation

Mit der App Ladestation können Ladestationen im Smart Building Automation System verwendet werden.

Die Ladestation-App ist unter Alle AppsLadestation zu finden.

Universelle Ladestation

Bei Auswahl der universellen Ladestation können herstellerunabhängig alle Ladestationen in das System eingebunden werden, die über eine Modbus-Schnittstelle verfügen.

Dementsprechend muss vor der Integration dieser Ladestation die Modbus-Kommunikation konfiguriert werden. Dies erfolgt über die App Modbus

Hinzufügen

Durch einen Klick auf Ladestation hinzufügen wird ein Wizard geöffnet.

Auf Universelle Ladestation klicken.
Danach kann die Ladestation wie gewünscht konfiguriert werden.

Verlinkungen

Damit die universelle Ladestation im Energiemanagement verwendet werden kann, muss unter Schreibende Werte folgendes verknüpft/definiert sein:

  1. Ladestrom Vorgabe [A]
  2. Minimaler Ladestrom [A]*
  3. Maximaler Ladestrom [A]*

Status:

  • Fehler: Hier kann ein boolscher Wert verknüpft werden, welcher aussagt, ob ein Fehler vorliegt
  • Fehlercode: Hier kann ein numerischer Wert verküpft werden, welcher den Fehlercode angibt. Dieser wird nur angezeigt, wenn der bei Fehler verknüpfte Wert true ist.
  • Fehlercode Werte benennen: Hier können beliebig viele numerische Fehlercodes, einem bestimmten Text zugewiesen werden.
  • Lädt: Hier kann ein boolscher Wert verknüpft werden, welcher aussagt, ob die Ladestation lädt. Wenn diese Verknüpfung leer bleibt, wird der Ladezustand durch die Verknüpfung von Anzeigewerte - Aktuelle Ladeleistung [kW] berechnet (0 = Lädt nicht, >0 = Lädt). Wenn auch diese Verknüpfung leer bleibt, dann wird der Ladezustand beim Starten/Stoppen der Ladestation geändert.
  • Ladekabel angeschlossen: Hier kann ein boolscher Wert verknüpft werden, welcher aussagt, ob das Ladekabel an die Ladestation angeschlossen ist
  • Auto bereit: Hier kann ein boolscher Wert verknüpft werden, welcher aussagt, ob das Auto geladen werden kann
  • Freigabe: Hier können Bedingungen verknüpft werden, welche zutreffen müssen, damit der Ladevorgang gestartet werden kann. Wenn hier keine Bedingungen verknüpft sind, ist die Freigabe dauerhaft auf true.

Anzeigewerte:
Die folgenden numerischen Werte können hier verknüpft werden, welche dann im Operator Panel als Information angezeigt werden. Je nachdem ob im Parameter Panel als Typ 1-Phasig oder 3-Phasig ausgewählt wurde, sind für die Spannung sowie den Strom, jeweils nur eine oder ansonsten drei Verlinkungen vorhanden.

  • Aktuelle Ladeleistung [kW]: Ladeleistung mir der gerade geladen wird
  • Gesamter Energiebedarf [kWh]: Der gesamte Energiebedarf der Ladestation seitdem diese erworben wurde
  • Energiebedarf des Ladevorgangs [kWh]: Energiebedarf seit dem Beginn dieses Ladevorgangs
  • Spannung [V]: Aktuelle Spannung
  • Strom [A]: Aktueller Strom

Schreibende Werte:
Wenn die Ladestation gesteuert werden soll und nicht nur als Visualisierung dient, sind hier folgende Werte zu verknüpfen:

  • Start: Hier kann ausgewählt werden, ob beim Start des Ladevorgangs ein numerischer oder boolscher Wert auf das verknüpfte Property geschrieben wird. Hierfür Nummer oder Boolean im Dropdown auswählen. Wenn Boolean ausgewählt wird, wird auf das verknüpfte Property beim Start des Ladevorgangs immer der Wert true geschrieben.
  • Startwert: Der numerischer Wert, welcher beim Start des Ladevorgangs auf das oben verknüpfte Property geschrieben wird. (Für boolschen Properties wie oben beschrieben nicht vorhanden)
  • Stopp: Hier kann ausgewählt werden, ob beim Start des Ladevorgangs ein numerischer oder boolscher Wert auf das verknüpfte Property geschrieben wird. Hierfür Nummer oder Boolean im Dropdown auswählen. Wenn Boolean ausgewählt wird, wird immer der Wert false, und wenn Nummer ausgewählt ist, immer der Wert 0 geschrieben auf das verknüpfte Property beim Start des Ladevorgangs geschrieben.
  • Ladestrom Vorgabe [A]: Hier kann ausgewählt werden, auf welches Property, der aktuelle Ladestrom geschrieben werden soll, mit welchem geladen wird.
  • Minimaler Ladestrom [A]*: Hier muss definiert werden, was der minimale Ladestrom ist, mit welchem das Auto geladen werden kann bzw. die Ladestation laden kann (nur sichtbar wenn die Ladestrom Vorgabe verknüpft ist)
  • Maximaler Ladestrom [A]*: Hier muss definiert werden, was der maximale Ladestrom ist, mit welchem das Auto geladen werden kann bzw. die Ladestation laden kann (nur sichtbar wenn die Ladestrom Vorgabe verknüpft ist)

Webasto

Bei Verwendung einer Webasto Ladestation, wird die Integration in das System wesentlich erleichtert, wobei die nachfolgenden Schritte zu beachten sind.

Vorbereitung

Bevor die Webasto-Ladestation in das Smart Building Automation System eingebunden werden kann, müssen folgende Schritte durchgeführt werden:

  • In der mit der Ladestation mitgelieferten Bedienungsanleitung müssen die Passwörter für die Ladestation sowie für den WLAN-Zugangspunkt nachgeschlagen werden. Diese befinden sich meist auf der ersten Seite.- Anschließend muss eine Verbindung mit dem WLAN der Ladestation hergestellt werden.
  • Danach muss die IP-Adresse des WLAN-Zugangspunktes im Browser eingegeben werden, um zum Interface der Ladestation zu gelangen, wo anschließend eine Anmeldung mit dem Master-Passwort und dem Benutzernamen admin vorgenommen wird.

Anzeigen aller Optionen (Nur für Ladestationen des Typs „Webasto Next“):
In der rechten oberen Ecke des Bildschirms auf das Profil klicken und den Expertenmodus aktivieren.

NETWORK:
Der Reiter NETWORK muss geöffnet werden.
Anschließend muss ausgewählt werden, ob die Ladestation mittels WLAN oder LAN in das Netzwerk eingebunden werden soll.
Es wird empfohlen, eine statische IP-Adresse zu konfigurieren, da es ansonsten zu Unannehmlichkeiten kommen kann.
Zudem muss sichergestellt werden, dass sich die Ladestation im selben Netzwerk wie der Controller befindet.

BACKEND - Connection type:
Der Reiter BACKEND muss geöffnet werden.
Bei einer Ladestation des Typs Webasto Live muss Folgendes ausgewählt werden:

  • „GSM“

Bei einer Ladestation des Typs Webasto Next muss Folgendes ausgewählt bzw. eingestellt werden:

  • Die Art der Netzwerkeinbindung der Ladestation
  • Die Connection URI muss auf „wss://ocpp.monta.app/“ geändert werden

Anschließend müssen diese Einstellungen gespeichert und die Ladestation neu gestartet werden.
Der Neustart kann einige Minuten dauern.

HEMS:
Sobald die Ladestation neu gestartet wurde, muss der Reiter HEMS geöffnet werden.

Bei Ladestationen des Typs Webasto Live müssen folgende Einstellungen vorgenommen werden:

  • Modbus TCP Server: „On“
  • Modbus TCP Server Port Number: „502“
  • Modbus Slave Register Address Set: „TQ-DM100“

Bei einer Ladestation des Typs Webasto Next müssen folgende Einstellungen vorgenommen werden:

  • Mode: „HEMS activated“
  • Port: „502“
  • Connection type: dieselbe Einstellung wie unter BACKEND

Authorization:
Bei einer Ladestation des Typs Webasto Live müssen folgende Einstellungen vorgenommen werden:

  • Kostenloses Laden/Free Charging: „Aus“

Bei einer Ladestation des Typs Webasto Next müssen folgende Einstellungen vorgenommen werden:

  • Kostenloses Laden/Free Charging: „Ein“
  • Im Zweifel Laden zulassen: „Ein“ (nur bei gewissen Versionen vorhanden)

Anschließend müssen die vorgenommenen Einstellungen gespeichert und die Ladestation erneut gestartet werden.
Danach kann die Ladestation in das System eingebunden werden.

Hinzufügen

Um eine Webasto Ladestation in das Smart Building Automation System einzubinden, wird die IP-Adresse des Geräts benötigt.

ACHTUNG! Damit die Ladestation in das System eingebunden werden kann, darf diese nicht bereits auf einem anderen Controller eingebunden sein. Zudem bitte überprüfen, dass auf diesem oder einem anderen Controller unter der App Modbus, keine Instanz die IP-Adresse der Ladestation hat.

Durch einen Klick auf Ladestation hinzufügen wird ein Wizard geöffnet.

Auf Webasto klicken.

Nun bitte die IP-Adresse der Ladestation eingeben und auf Weiter klicken. Nun wird mit der zuvor eingegebenen IP-Adresse eine Verbindung aufgebaut und falls es sich um eine Webasto Ladestation handelt, wird diese hinzugefügt.

Bedienung

Im Operator Panel werden die wichtigsten Kennzahlen sowie der Status des Ladevorgangs angezeigt, darunter die aktuelle Ladeleistung, die abgegebene Ladeenergie und der aktuelle Ladestrom. Das Symbol des Autos und der Ladestation verändert sich mit dem Status des Ladevorgangs und des angeschlossenen Kabels:

  • Auto und Ladestation grau: Es ist kein Auto und auch kein Kabel angeschlossen
  • Auto grau und linker Teil des Kabels fehlt, rechter Teil des Kabels und Station blau: Es ist kein Auto aber ein Kabel an die Station angeschlossen
  • Alles blau: Es ist ein Auto an die Station angeschlossen, jedoch wird noch nicht geladen
  • Alles türkis: Auto ist angeschlossen und wird geladen

Zudem kann hier der Ladestrom geändert werden. Wird dieser auf 0.0A gestellt, lädt die Station nicht mehr.

Im zweiten Teil des Operator Panels wird die Energiebilanz angezeigt. Dabei werden sowohl die Gesamtenergie, die insgesamt über die Ladestation bezogen wurde, als auch die Energie, die für den aktuellen Ladevorgang bereits verwendet wurde, dargestellt.

Darunter befindet sich ein Histogramm, in dem der Energiebedarf dargestellt wird. Zusätzlich kann dort zum aktuellen Energiebedarf auch der Bedarf des Tages, der Woche, des Monats und des Jahres angezeigt werden.

Wenn Vergleichswerte vorhanden sind, wird unter dem Histogramm angezeigt, wie viel mehr oder weniger Energie im Vergleich beispielsweise zum vorherigen Tag verwendet wurde.

Im Parameter Panel ist neben der Bezeichnung und dem Bereich auch der Verbindungsstatus zur Ladestation ersichtlich. Solange ein rotes „X“ angezeigt wird, ist die Ladestation nicht verbunden, ein grünes Häkchen verweist auf eine hergestellte Verbindung.
Unter dem Reiter „Einstellungen“ können die IP Adresse sowie der verwendete Port geändert werden. Darüber hinaus gibt es auch die Einstellmöglichkeit, ob nach dem vollständigen Aufladen des Autos eine Benachrichtigung gesendet werden soll.

In den allgemeinen Informationen ist der Ladestatus, der Status des Kabels, der minimale und maximalen Fehlerstrom sowie bei einem Fehler der entsprechende Code ersichtlich.

Am Ende des Panels können Sie noch genauere Daten bezüglich des aktuellen Ladevorgangs für die einzelnen Phasen (nur wenn die Ladestation 3-phasig angeschlossen ist) und des gesamten Energiebedarfs seit der ersten Inbetriebnahme einsehen.

Szenen

Die Ladestation App bietet folgende Funktionen für Szenen (dann ...):

  • Ladestrom setzen: Den Ladestrom der Station ändern
  • Ladevorgang abbrechen: Der aktuelle Ladevorgang wird abgebrochen (nicht möglich bei einer Ladestation vom Typ Webasto Live)
  • Ladevorgang starten: Es wird ein neuer Ladevorgang gestartet, falls nicht bereits einer aktiv ist (nicht möglich bei einer Ladestation vom Typ Webasto Live)

Logik

Die Ladestation App bietet folgende Möglichkeiten für die Verwendung in Logiken:

  • Fehler: Ob ein Fehler aktiv ist (lesen)
  • Lädt: Ob die Ladestation gerade lädt (lesen)
  • Laden: Hiermit kann gesteuert werden, ob die Ladestation laden soll oder nicht (schreiben)
  • Ladestrom: Der aktuelle Ladestrom [A] (lesen/schreiben)
  • Aktuelle Leistung: Die aktuelle Leistung der Ladestation [kW] (lesen)
  • Bisheriger Energiebedarf: Bisheriger Energiebedarf des aktuellen Ladevorgangs [kWh] (lesen)
  • Gesamter Energiebedarf: Gesamter Energiebedarf der Ladestation seit Inbetriebnahme [kWh] (lesen)

Verwendung im Energiemanagement

Damit universelle Ladestationen im Energiemanagement verwendet werden können, muss alles im Reiter Universelle Ladestation - Verlinkungen beachtet werden!

Damit Webasto Ladestationen im Energiemanagement verwendet werden können, muss alles im Reiter Webasto - Vorbereitung beachtet werden.

Light

A light in the Smart Building Automation system corresponds to a lighting channel connected to a light module. Once connected, each light can be switched on and off. In addition, the predefined universal functions "All Lights ON" and "All Lights OFF" are available.

The App is available under "all apps".

Usage

You can switch a light on or off via the “power symbol” on the left side. The right-hand side of the panel shows you whether the light is currently switched on or off. Clicking on the element takes you into the extended operation or configuration of this light. You can switch the light on or off by clicking on the bulb symbol.

If you have a dimmable light, you can switch in on or off via the object panel. Of course, you can also control this dimmable light via the operator panel by setting the circular slider around the light to the desired value.

RGBW

If you own a RGBW Module (HC-L1644), you can control the desired light color and brightness from within the OperatorPanel.

Additionally, you can also save the current light settings as a favorite and activate it again later.

Saved favorites will also be displayed in the ObjectPanel, if you resize it to the appropriate size.

Configuration

Once a light has been given a name, you can configure it to suit your needs.

General

Mode
This setting determines whether this light is controlled by a switch or a presence detector. If you select “presence detector”, the settings to adjust the time the light is switched on are displayed.

Activate daylight lock
This option lets you prevent the light from switching on during the day (if there is sufficient light). This can be used for a hallway where the light is controlled by a presence detector. You can adjust the source for daylight detection in the global settings.

Lock
If you activate “lock”, then the light cannot be switched on or off by the switch, nor by the presence detector.

Activate energy saving mode
This option lets you configure the light to switch itself off after a certain time. If you have activated this option, then the software shows you the settings for the time the light is to remain switched on. You can change this time to anything you want.

Remove from universal scene
An example of a universal scene is “all lights off”, where all lights are switched off. However, if you want a particular light to be excepted from this, then activate this option (useful for lighting an aquarium).

Reserve
If you have a module with spare connections, i.e. where no light is connected, the app still shows that the light is on or off, because the output is active (although no light is actually connected). The “reserve” field lets you hide lights that are not used/connected. You can reactivate this light via the corresponding module in the app “hardware”.

Dimmer

Minimum and maximum brightness
Minimum and maximum brightness: many lights only have a noticeable change in brightness within a certain range. Hence you can set a minimum and maximum brightness level so that dimming will happen in between those limits. The visualization will still display 0% to 100%.

Fade in time
This is the time that the light is to take to reach the desired brightness from being switched off.

Dim speed
This is how fast the brightness is reached when the button is pressed continuously.

Warmweiß/Kaltweiß

Diese Einstellungen gelten nur für Dali Leuchten, welche eine Warmweiß/Kaltweiß Steuerung ermöglichen.

Farbtemperatur einstellbar
Zeigt den Slider zum Einstellen der Farbtemperatur in der Bedienung an.

Mindestfarbtemperatur
Entspricht dem Mindestwert in Mirek welcher auf der Leuchte gesetzt werden kann. Dieser Wert kann aus dem Datenblatt der Leuchte entnommen werden und kann einen Wert zwischen 1 und 65534 haben.

Maximalfarbtemperatur
Entspricht dem Maximalwert in Mirek welcher auf der Leuchte gesetzt werden kann. Dieser Wert kann aus dem Datenblatt der Leuchte entnommen werden und kann einen Wert zwischen 1 und 65534 haben.

RGBW

Minimum brightness
Legt die kleinste Helligkeitsstufe fest
Set the minimum brightness level

Maximum brightness
Set the maximum brightness level

Fading time
This will set the time it takes for the light to dimm between "on" and "off" state rather than switching instantly.

Dimm speed
Sets the time it takes for the light to dimm to the desired brightness.

Color changing speed
This setting will affect how fast the light switches through all available colors when using the linked switch with a longpress.

Only white
When this setting is active, the color wheel will be hidden and only the brightness slider is available in the OperatorPanel.

Enable saving energy
Enables the energy saving mode, in which the light will switch itself off after a given time. You can adjust the desired time with the given interface elements, which appear once this setting is active.

Exclude from universal scene
Activating this option will exclude it from Universal scenes which will not impact this light anymore until this option is turned off.

Switch off automatically after
This option only appears after the "enable saving energy" setting it active. It allows you to adjust the time it takes for the light to switch itself off.

While the standard mode of the RGBW Module is "1xRGBW" it is also possible to switch to "4xWhite". This will allow you to connect 4 separate lights to one RGBW module and use them like normal dimmable lights. To change this setting, go to "All apps" - "Hardware" and navigate to the correct module ("Light1644"). Click on the Name and change the setting in the appearing OperatorPanel.

Linking

Linking allows a light to be connected to other elements in the Smart Building Automation system.

Switch on with
To switch on this light when another light is switched on, use the "Switch on with" function. Then use the "Select" button to choose the light to be linked.

Add motion detector/add button
Additional motion detectors or buttons can be assigned to a light channel to control the light.

The function of a linked button or motion detector depends on the autonomous light function and whether button or motion detector mode is selected.

Gruppenfunktion

Über die Gruppenfunktion lassen sich mehrere Lichter zu einer Gruppe zusammenfassen. Dadurch werden alle gleichzeitig geschalten.

Um eine neue Lichtgruppe anzulegen, „Neue Lichtgruppe“ innerhalb der Licht App auswählen.

Eine neue Lichtgruppe wird erstellt.

In den Einstellungen der Gruppe sollte zunächst ein Name vergeben und ein Raum zugeordnet werden.

Hier besteht außerdem die Möglichkeit, die Gruppe zu deaktivieren. Dadurch kann eine bereits konfigurierte Gruppe vorübergehend deaktiviert werden, ohne diese löschen zu müssen.

Für erweiterte Anwendungen kann die Lichtgruppe auch über die Logik-App deaktiviert werden.

Bei einer starren Kopplung werden immer alle Lichter gemeinsam geschaltet, auch wenn der zugehörige Taster eines einzelnen Lichtes betätigt wird. Ist die starre Kopplung deaktiviert (lose Kopplung), schalten die zu einem Licht gehörenden Taster nur das jeweilige Licht. Nur die in der Lichtgruppe definierten Taster schalten alle Lichter der Gruppe gemeinsam.

Zusätzlich können die Ein-/Ausblendezeit und die Dimm-Geschwindigkeit für die verbundenen dimmbaren Lichter festgelegt werden. Sobald dimmbare Lichter mit der Lichtgruppe verbunden sind, werden die Ein-/Ausblendezeit und die Dimm-Geschwindigkeit von der Lichtgruppe übernommen und können bei den einzelnen Lichtern nicht mehr verändert werden.

Der Lichtgruppe können mehrere Lichter hinzugefügt werden. Alle Lichter innerhalb der Gruppe werden gemeinsam geschaltet. Wird ein Licht der Gruppe ausgeschaltet, werden auch alle anderen Lichter ausgeschaltet. Handelt es sich bei einem der Lichter um einen Dimmer, wechselt dieser zwischen „Aus“ und der zuletzt eingestellten Dimmstufe.

Die Gruppenfunktion wirkt sich sowohl auf die Bedienung über die Visualisierung des Smart Building Automation Systems als auch über Taster und Bewegungsmelder aus. Zusätzlich können jeder Gruppe weitere Taster hinzugefügt werden.
Sobald ein Licht mit einer Lichtgruppe verbunden ist, werden die externen Taster des Lichtes gelöscht und die externen Taster der Lichtgruppe übernommen.

Bei einem kurzen Tastendruck wird der Status der Lichter umgeschaltet. Bei einem langen Tastendruck werden verknüpfte dimmbare Lichter auf- bzw. abgedimmt. Nach dem Loslassen und einem erneuten langen Tastendruck wird in die entgegengesetzte Richtung gedimmt.
Dabei verhalten sich alle Taster gleich, unabhängig davon, ob es sich um die Autark-Taster der verknüpften Lichter oder um externe Taster handelt. Sind sowohl dimmbare als auch nicht dimmbare Lichter in einer Gruppe verknüpft, werden die nicht dimmbaren Lichter bei einem langen Tastendruck eingeschaltet. Die dimmbaren Lichter werden so lange auf- bzw. abgedimmt, wie der Taster gedrückt wird.

Im Regelfall können Lichter und Taster nur einer Lichtgruppe zugeordnet werden. Für spezielle Anwendungen können jedoch auch bereits verknüpfte Lichter und Taster einer weiteren Lichtgruppe hinzugefügt werden. Diese Einstellung kann im Parameter Panel unter „Erweiterte Parameter“ konfiguriert werden.

Achtung: Lichter und Taster mit mehreren Lichtgruppen zu verknüpfen ist nur dann sinnvoll, wenn immer nur eine Lichtgruppe aktiviert ist. Beispielanwendungen hierfür sind Räume, welche über Trennwände aufgeteilt werden. Hier kann es sinnvoll sein, dass Lichtgruppen je nach geschlossener oder geöffneter Trennwand deaktiviert werden.

In der Gruppe können alle verbunden Lichter gesteuert werden. Wenn nur nicht dimmbare Lichter verbunden wurden, können diese über das Operator Panel ein- bzw. ausgeschalten werden. Sobald ein dimmbares Licht hinzugefügt wird steht auch das Bedienelement zum Anpassen der Helligkeit zur Verfügung, hier werden dann nicht dimmbare Lichter nur ein- bzw. ausgeschalten und dimmbare Lichter gedimmt. Sobald ein RGBW Licht verbunden ist, wird zusätzlich der Farbkreis zur Auswahl angezeigt. Dimmbare Lichter werden dann mitgedimmt und alle Lichter entsprechend Ein- bzw. Ausgeschalten. Außerdem können für RGBW Lichtgruppen Favoriten erstellt werden.

Lichtgruppen in Szenen

Lichtgruppen bieten folgende Auslöser für Szenen (wenn ...):

  • Gruppe wurde ausgeschaltet: Die Lichtgruppe wurde ausgeschaltet
  • Gruppe wurde eingeschaltet: Die Lichtgruppe wurde eingeschaltet

Lichtgruppen bieten folgende Funktionen für Szenen (dann ...):

  • Aktivieren: Aktiviert die Lichtgruppe
  • Ausschalten: Schaltet alle Lichter der Lichtgruppe aus
  • Blinken: Alle Lichter der Lichtgruppe beginnen zu blinken
  • Blinken beenden: Alle Lichter der Lichtgruppe stoppen zu blinken
  • Deaktivieren: Deaktiviert die Lichtgruppe
  • Dimmen: Dimmt alle Lichter der Lichtgruppe (nur bei Lichtgruppen mit dimmbaren Lichtern). Wenn zusätzlich eine Zeit definiert wird, dann werden die Lichter über die Zeit hinweg auf den ausgewählten Wert gedimmt. ACHTUNG: Die definierte Zeit entspricht der Zeit die es dauern würde, wenn das Licht eine Helligkeit von 0% hat und auf 100% gedimmt wird. Abhängig von der aktuellen Helligkeit des Lichts, ist das Dimmen dementsprechend schneller abgeschlossen.
    - Um X Prozent hochdimmen: Die Lichter werden um einen definierbaren Prozentsatz hoch gedimmt (nur dimmbare Lichter)
    - Um X Prozent runterdimmen: Die Lichter werden um einen definierbaren Prozentsatz runter gedimmt (nur dimmbare Lichter)
  • Dimmen stoppen: Der Dimmvorgang aller Lichter (wenn über Dimmen mit Zeit ausgelöst) wird gestoppt
  • Einschalten: Schaltet alle Lichter der Lichtgruppe ein
  • Einschalten für: Schaltet alle Lichter für eine frei wählbare Zeit ein
  • Farbtemperatur setzen: Setzt die Farbtemperatur aller Lichter in der Lichtgruppe (nur bei Lichtgruppen mit DALI WW/WK oder Philips hue White ambiance Lichtern)
  • Favoritenfarbe aktivieren: Alle Lichter der Lichtgruppe schalten auf die Favoritenfarbe (nur bei Lichtgruppen mit RGBW Lichtern)
  • Umschalten: Alle Lichter der Lichtgruppe werden umgeschaltet
  • Zu nächstem Favorit springen: Alle Lichter schalten auf die nächste Favoritenfarbe (nur bei Lichtgruppen mit RGBW Lichtern)
Motion Detector

If a light channel is connected to the input of a presence detector, then this light will always be automatically switched off after the defined time independently of whether an additional button or presence detector is switched on.

A presence detector light can be immediately manually switched off using an additional button.

If the time for the presence detector is to be used, then the time for the light must be set to 0. If the time for the light is to used, then the time for the presence detector must be set to 0.

Additional buttons
The light can be switched off at any time with an additional button linked to this light channel (or on, if required). If the light is switched on via the button, it is also switched off after the defined period of time.

Note that in this case, the energy saving time cannot be 0, because otherwise the button input would be immediately switched off – and hence not seem to work.

Additional presence detector
An additional presence detector can also switch the light off after the defined period of time.

Note that in this case, if the energy saving time is defined with 0, then the on/off times for the light will vary due to the times defined by the presence detector.

Switch

If a light channel input is connected to a button, this light will be switched by every linked button or presence detector according to the autonomous function.

If no automatic switch-off time is defined (energy saving mode), then the presence detector can only switch the light on.

Additional button
The light can be switched on or off at any time using an additional button linked to this light channel.

Note that in this case, the energy saving time cannot be defined as 0, as otherwise the light would be switched off immediately after the button press – and therefore not seem to work.

Additional presence detector
An additional presence detector will always switch the light on and switch it off after the defined period of time.

Settings

General settings that apply to all lights can be configured under "All Apps - Settings - Lights".

Daylight lock delayed switching
The daylight lock can be configured under "Settings" > "Lights". Here, the delay in minutes for deactivating the daylight lock after dusk and activating it after dawn can be defined. For example, if dusk is detected at 8:00 PM and a delay of 10 minutes is configured, the daylight lock is deactivated at 8:10 PM.

Szenen

Lichter bieten folgende Auslöser für Szenen (wenn ...):
- Licht wurde ausgeschaltet: Das Licht wurde ausgeschaltet
- Licht wurde eingeschaltet: Das Licht wurde eingeschaltet

Lichter bieten folgende Funktionen für Szenen (dann ...):
- Alle ausschalten: Alle Lichter werden ausgeschaltet
- Alle einschalten: Alle Lichter werden eingeschaltet
- auf Dauerhaft-EIN Betrieb stellen: Das Licht wird dauerhaft eingeschalten
- Auf Modus nur Weiß umschalten: Das RGBW Licht wird auf den Modus zur Weiß-Steuerung umgeschaltet
- Auf Modus RGBW umschalten: Das RGBW Licht wird auf den Modus zur RGBW-Steuerung umgeschaltet
- auf Normal Betrieb stellen: Das Licht kann wieder normal ein- und ausgeschalten werden
- Ausschalten: Das Licht wird ausgeschaltet
- Blinken: Das Licht beginnt zu blinken
- Blinken beenden: Das Licht stoppt zu blinken
- Dimmen: Das Licht wird gedimmt. Wenn zusätzlich eine Zeit definiert wird, dann wird das Licht über die Zeit hinweg auf den ausgewählten Wert gedimmt. ACHTUNG: Die definierte Zeit entspricht der Zeit die es dauern würde, wenn das Licht eine Helligkeit von 0% hat und auf 100% gedimmt wird. Abhängig von der aktuellen Helligkeit des Lichts, ist das Dimmen dementsprechend schneller abgeschlossen. (nur dimmbare Lichter)
- Dimmen stoppen: Der Dimmvorgang (wenn über Dimmen mit Zeit ausgelöst) wird gestoppt
- Um X Prozent hochdimmen: Das Licht wird um einen definierbaren Prozentsatz hoch gedimmt (nur dimmbare Lichter)
- Um X Prozent runterdimmen: Das Licht wird um einen definierbaren Prozentsatz runter gedimmt (nur dimmbare Lichter)
- Einschalten: Das Licht wird eingeschaltet
- Einschalten für: Das Licht wird für eine frei wählbare Zeit eingeschaltet
- Farbduchlauf starten: Das RGBW Licht durchläuft alle Farben
- Farbduchlauf starten für: Das RGBW Licht durchläuft alle Farben über den gewählten Zeitraum
- Farbduchlauf stoppen: Das RGBW Licht stoppt den Farbdurchlauf
- Farbtemperatur setzen: Die Farbe des Lichts wird umgeschaltet (nur Philips Hue White ambiance)
- Favoritenfarbe aktivieren: Das RGBW Licht schaltet auf die Favoritenfarbe
- Farbe setzen über RGBW: Das RGBW Licht übernimmt die eingegebenen Werte und verändert die Farbe gegebenenfalls (nur RGBW Lichter)
- Farbe setzen über X und Y: Das Licht übernimmt die eingegebenen Werte und verändert die Farbe gegebenenfalls (nur gewisse Dali-Lichter)
- Gedimmt einschalten für: Das Licht wird für eine definierbare Zeit mit einer definierbaren Helligkeit eingeschalten (nur dimmbare Lichter)
- Sperren: Das Licht wird gesperrt
- Umschalten: Das Licht wird umgeschaltet
- Zu nächstem Favorit springen: Falls vorhanden wird zum nächsten Favorit gewechselt (nur RGBW Lichter)

DALI

Das DALI Modul ermöglicht die komfortable Steuerung von DALI Lampen mit dem Smart Building Automation System.

Mit dem Modul L1842 können zwei DALI Linien mit jeweils bis zu 16 Lichtern gesteuert werden.
Mit dem Modul L1942 können zwei DALI Linien mit jeweils bis zu 32 Lichtern gesteuert werden.
Für das Modul L1942 ist ein externes DALI Netzteil erforderlich.

Nähere Informationen zur Verkabelung der DALI Linien sind im mitgelieferten Datenblatt des Moduls zu finden.

Es werden nur DALI Lampen und Vorschaltgeräte unterstützt, die nach dem DALI Standard IEC 62386 genormt sind.

Bedienung

Sie finden Ihre DALI Module unter „Alle Apps“ - „Hardware"

Im Parameter Panel können Sie entscheiden, ob Sie den Expertenmodus verwenden möchten.

Standardmodus: Alle Lichter auf einer DALI Linien können gemeinsam geschalten werden. Zusätzlich werden die Lichter der Linien mit den Taster der Kanäle 1 und 2 geschaltet.

Expertenmodus: Der Expertenmodus erlaubt die Steuerung jeder einzeln angeschlossenen Lampe. Hierfür müssen alle angeschlossenen Lampen adressiert werden. Die Taster der Kanäle 1 und 2 werden nicht für die Steuerung der Lampen verwendet.

Zusätzlich haben Sie im Parameter Panel die Möglichkeit, die Steuerungsbefehle Ein, Aus und Dimmen auf eine DALI Linie auszuführen.

Durch Klick auf den linken Bereich des Object Panels oder durch Klick im Operator Panel auf „Kanäle anzeigen“ werden alle Taster und Lichter des Moduls aufgelistet. In der Standardkonfiguration werden hier 2 Lichter aufgelistet, welche jeweils die Lampen einer DALI Linien repräsentieren.

Expertenmodus

Mit dem Expertenmodus können alle angeschlossenen Lichter adressiert und anschließend getrennt gesteuert werden. Bei der Adressierung wird jeder angeschlossenen Lampe eine innerhalb der jeweiligen Linie eindeutige Adresse zugeordnet.

Zum Aktivieren des Expertenmodus im Parameter Panel auf „Expertenmodus“ klicken.

Nach der Aktivierung werden die zwei Lichter entfernt, welche die gesamten Linien repräsentieren. Zusätzlich wird die Autarkfunktion der Taster deaktiviert, wodurch die Taster frei verwendet werden können. Im Parameter Panel stehen anschließend die Werkzeuge zum Adressieren der Lichter zur Verfügung.

Zum Adressieren zunächst die gewünschte Linie und anschließend den Adressierungsmodus auswählen.

Durch einen Klick auf „Adressierung starten“ werden die Adressen unter den angeschlossenen Lampen ausgehandelt. Anschließend werden die adressierten Lampen im Smart Building Automation System aufgelistet.

Adressierungsmodus „Alle Lichter neu adressieren":
In diesem Modus werden vorhandene Lichter gelöscht und alle Lichter neu adressiert.

Adressierungsmodus „Neue Lichter adressieren":
In diesem Modus werden nur neue Lichter hinzugefügt, die noch nie adressiert wurden. Vorhandene Lichter bleiben erhalten.

Auch im Expertenmodus kann die Autarkbedienung über die Taster des Moduls verwendet werden. Ist die Autarkfunktion aktiviert, werden mit den Tastern alle Lichter der jeweiligen DALI Linie geschaltet.

Nach der Adressierung werden alle gefundenen Lampen unter den Kanälen des Moduls angezeigt. Die Kanäle können durch einen Klick auf den linken Bereich des Moduls oder über „Kanäle anzeigen“ im Operator Panel aufgerufen werden.

Zusätzlich werden alle Lichter unter „Alle Apps“ - „Lichter“ aufgelistet. Dort können wie gewohnt verwendet und mit Szenen oder Lichtgruppen verknüpft werden.

Lampentausch:
Nach dem Austausch einer Lampe muss die neue Lampe adressiert werden.

Mithilfe der Funktion „Lampentausch“ im Parameter Panel wird die neu verbaute Lampe automatisch adressiert.

Alle bestehenden Szenen und Verknüpfungen im System bleiben erhalten.

Sollen alle Lichter einer Linie immer gemeinsam geschaltet werden, empfiehlt es sich, den Expertenmodus zu deaktivieren. Das Schaltverhalten ist dadurch wesentlich synchroner als bei einer Verknüpfung aller einzelnen Lichter.

Dynamisches RGB Licht

Mit der App „Dynamisches RGB Licht“ lässt sich ein RGB Licht erstellen, welches aus 3 einzelnen dimmbaren Lichtern besteht. z.B. wenn 3 einzelne Dali Lichter verbunden sind, welche jeweils einen einzelnen Kanal für Rot, Grün und Blau steuern. Die App „Dynamisches RGB Licht“ befindet sich unter „Alle Apps“ - „Lichter“

Erstellen

Mit „Funktion hinzufügen“ > „Dynamisches RGB Licht“ kann ein neues dynamisches RGB Licht erstellt werden.

Danach öffnet sich ein Wizard, über welchen die 3 einzelnen Lichter ausgewählt werden können. Jeweils ein dimmbares Licht für Rot, Grün und Blau.

Konfiguration

Das dynamische RGB kann gleich konfiguriert werden wie andere RGB Lichter, abgesehen von der Funktion „Farbdurchlaufzeit“ und „Nur Weiß“.
Siehe: RGB Konfiguration

Bedienung

Das dynamische RGB hat die selben Funktionen wie andere RGB Lichter, abgesehen von der Funktion „Farbdurchlauf“.
Siehe: RGB Bedienung

Lichtspiel

Mit der App „Lichtspiel“ lassen sich verschiedene Lichtmuster auf einer Gruppe von Lampen erzeugen. Die App „Lichtspiel“ befindet sich unter „Alle Apps“ - „Lichter“.

Erstellen

Mit „Funktion hinzufügen“ > „Lichtspiel“ kann ein neues Lichtspiel erstellt werden.

Im Parameter Panel können dann die Lichter ausgewählt werden und in gewünschter Reihenfolge sortiert werden.

Bedienung

Programm starten
Mit dem Button „Programm starten“ kann ein Programm gestartet werden (Details siehe unten).

Programm beenden
Mit dem Button „Programm beenden“ kann ein aktuell aktives Programm wieder beendet werden.

Lichter
Hier werden die ausgewählten Lichter und der aktuelle Status angezeigt.

Nach einem Klick auf „Programm starten“ öffnet sich ein Wizard, über welchen ein Programm gewählt werden kann. Hier kann zwischen „Treppenlicht“ und „Wassertropfen“ ausgewählt werden.

Beim „Treppenlicht“ handelt es sich um eine Funktion, wo z.B. einzelne Stufen einer Treppe Schritt für Schritt zugeschaltet werden können.
z.B. könnte hier folgendes Muster erzeugt werden: Oberste Stufe wird eingeschaltet, 1s warten, zweite Stufe wird eingeschaltet, 1s warten, dritte Stufe wird eingeschaltet,...

Beim Beenden werden die Lichter in selber Reihenfolge ausgeschalten, wie sie eingeschalten wurden.

Hier können folgende Parameter vergeben werden:

Leuchtdauer pro Licht [s]: Gibt an, wie lange ein Licht leuchtet, bevor das nächste Licht dazu geschalten wird.
Rückwärts ausführen: Wenn diese Option gewählt wurde, werden die Lichter in umgekehrter Reihenfolge eingeschalten.

Bei „Regentropfen“ handelt es sich um eine Funktion, wo z.B. bei LED Streifen einzelne Lichter nacheinander angesteuert werden können, um so den Effekt von fallenden Wassertropfen zu simulieren.
z.B. könnte hier folgendes Muster erzeugt werden: Oberste LED wird eingeschaltet, 1s warten, oberste LED wird ausgeschaltet, zweite LED wird eingeschaltet, 1s warten, zweite LED ausschalten, dritte LED einschalten,...

Beim Beenden werden alle Lichter ausgeschalten.

Hier können folgende Parameter vergeben werden:

Leuchtdauer pro Licht [s]: Gibt die Zeit an, wie lange ein Licht leuchten soll, bevor es wieder ausgeschalten wird.
Startverzögerung [s]: Gibt die Zeit an, wann das Programm starten soll, bzw. die Pause zwischen 2 vollständigen Durchläufen.
Pause zwischen zwei Lichtern [s]: Gibt die Zeit an, welche zwischen dem Ausschalten eines Lichts und des Einschalten des nächsten Lichts gewartet werden soll.
Endlos ausführen: Wenn diese Option gewählt wurde, wird nach dem ausführen eines Zyklus wieder von vorne gestartet.
Rückwärts ausführen: Wenn diese Option gewählt wurde, werden die Lichter in umgekehrter Reihenfolge eingeschalten.

Szenen

Das Lichtspiel bietet folgende Funktionen für Szenen (dann ...):
- Programm beenden: Beendet das aktuelle Programm
- Programm Regentropfen starten: Startet das Programm „Regentropfen“
- Programm Treppenlicht starten: Startet das Programm „Treppenlicht“

Logik

Lichter bieten folgende Möglichkeiten für die Verwendung Logiken:
-- Dauerhaft EIN: Ob das Licht dauerhaft eingeschalten ist (lesen und schreiben)
-- Fehler: Ob ein Fehler erkannt wurde (lesen)
-- Licht eingeschaltet: Ob das Licht eingeschalten ist (lesen)
-- Sperren: Ob das Licht gesperrt ist (lesen)
-- Externer Bewegungsmelder sperren: Hiermit kann die Aktivierung des Lichts durch einen verknüpfen Bewegungsmelder aufgehoben werden (schreiben)
-- Skalierte Helligkeit: Die skalierte Helligkeit in Prozent von dimmbaren Lichtern lesen (lesen)
-- Helligkeit setzen: Die skalierte Helligkeit in Prozent bei dimmbaren Lichtern setzen (schreiben)
-- Modus Nur Weiß aktiv: Gibt an, ob der Modus Nur Weiß aktiv ist (lesen, nur bei RGBW Lichtern)
-- Automatik Programm aktiv: Gibt an, ob der automatische Farbdurchlaufsmodus aktiv ist (lesen, nur bei RGBW Lichtern)
-- Farbtemperatur setzen: Die Farbtemperatur eines DALI-Lichts setzen (schreiben)

Logic

The logic app enables you to execute complex operations for which there is no app. For example, this could be controlling the ventilation of the WC, controlling a light transformer etc. If you wish to use logic, then you should already have a basic understanding. If you are new to the area of logic, exercise caution when using this feature.

The logic app is located under “all apps” – “logic”.

Logic Program

To create a logic sequence, you first need a logic program. This is comparable to a network in PLC programming. A program contains logic elements that you can use for your controller. For example, if you have a controller for the WC ventilation and one for a light transformer, then you can create an individual program for every controller.

Create

To create a logic program, open “logic” and select “add program”. This opens the operator panel for the logic program. You must first allocate a name to your program and optionally a room for it.

Parameter

The operator panel for the logic program contains an item “parameter” where all parameters available to rapidly configure the program are listed (parameters are described in the chapter data elements). The values of these parameters are not lost if a controller fails.

Status

The item “status” displays a diagram that shows you the time required to execute this program.

Control Command And Status Text

Every logic program can contain a control command and a status text. You can select a data element of type bool for the control command and a data element of type string (text). To do this, go to the parameter panel and select “choose control command and status text”.

The control command is intended to activate and deactivate the logic program via the object panel. You can toggle the control command via the icon on the left-hand side of the object panel.

The status text is displayed in the object panel under the name of the program. An example would be “ventilation will be switched off in 2 mins”.

Edit Logic

If you want to edit the logic in this program, click on the button “edit” in the parameter panel under the item “logic”.

Input und Output

Inputs and outputs can be defined for each logic program and are then displayed in the program's link panel. Defined inputs and outputs can be linked to values from other apps within the system.

This function allows interfaces to be defined for a logic program. The program can then be used without having to modify it when changing the linked values. Logic programs can also be easily reused for different purposes, as only the respective links need to be adjusted.

To define an input or output for a logic program, select a data element and change its type from "Internal" to "Input" or "Output".

The input or output is then displayed in the logic program's link panel and can be linked to the required app/value.

Import/export

If you wish to save the logic program, you can do this via the button “export” in the parameter panel under the item “import/export”.
To import a logic program, click on the button “import” (directly under the “export” button). Note that any existing logic is overwritten by the logic in the imported program. Furthermore, if logic elements were linked across programs prior to export, after importing, the links no longer exist.

Color And Icon

You can allocate a colour and icon to your logic program. Do this in the parameter panel under the item “settings” by clicking on the current colour or icon.

Editor

Ab Smart Building Automation Version 2.13 steht eine alternative Möglichkeit zur Bearbeitung von Logikprogrammen zur Verfügung. Die neue Logikansicht kann direkt über das Operator Panel geöffnet werden.

Upgrade bestehender Logiken
Logiken aus Versionen vor 2.13 werden beim erstmaligen Öffnen in der neuen Ansicht automatisch aktualisiert. Dabei werden einige Anpassungen vorgenommen. Nach dem Upgrade sollte das Logikprogramm überprüft werden, um sicherzustellen, dass alle Funktionen weiterhin wie erwartet funktionieren. Änderungen

Überblick

Die neue Logikansicht basiert auf einer SPS-ähnlichen Ansicht und bietet eine intuitive grafische Oberfläche zur Erstellung und Bearbeitung von Logikgruppen. Die Benutzeroberfläche besteht aus folgenden Hauptelementen:

Steuerungselemente: Buttons zum Bearbeiten, Hinzufügen, Duplizieren und Zurücksetzen der Logikgruppe.
Bibliotheksbereich: Enthält alle verfügbaren Logikbausteine, kategorisiert nach Funktionsgruppen (Datenbausteine, Logikverknüpfungen, Zeitfunktionen und Sonstige).
Bearbeitungsfläche: Der Hauptarbeitsbereich, in dem die Logikbausteine platziert und verbunden werden können.
Die Bearbeitungsfläche verfügt über ein Raster, das die präzise Positionierung der Bausteine erleichtert. Die Bausteine werden automatisch am Raster ausgerichtet, um eine übersichtliche Darstellung zu gewährleisten.

Bedienung des Editors

Die Logikansicht bietet zwei Hauptmodi:

Ansichtsmodus: In diesem Modus kann die Logikgruppe als Gesamtes verschoben und angesehen werden, aber keine Änderungen an den Verbindungen vorgenommen werden.

Bearbeitungsmodus: In diesem Modus können Logikbausteine hinzugefügt, verschoben, verbunden, gelöscht und konfiguriert werden.

Um in den Bearbeitungsmodus zu wechseln, kann auf den Bearbeiten-Button (Stift-Symbol) geklickt werden. Im Bearbeitungsmodus wird die Bibliothek verfügbar, und es kann mit der Erstellung oder Änderung der Logikgruppe begonnen werden.

Ansicht anpassen
Die Logikansicht bietet verschiedene Möglichkeiten zur Anpassung der Darstellung:
Zoom: Mit gedrückter Strg-Taste kann mit dem Mausrad hinein- oder herausgezoomt werden.
Verschieben: Die gesamten Elemente können durch Klicken und Ziehen bewegt werden.
Ansicht zurücksetzen: Mit dem Zentrier-Button kann die Ansicht auf den Standardzustand zurückgesetzt werden.

Bibliothek anheften
Die Bibliothek kann im Bearbeitungsmodus dauerhaft sichtbar bleiben:
Es kann durch Klicken auf den Hinzufügen-Button (+) die Bibliothek geöffnet, anschließend durch den Pin-Button angepinnt und somit dauerhaft sichtbar gehalten werden, auch während anderer Aktionen.

Speichern und Zurücksetzen
Beim Verlassen des Bearbeitungsmodus (wieder über den Bearbeiten-Button oder über Strg+S) erscheint ein Popup und folgende Optionen stehen zur Verfügung:
Speichern: Alle Änderungen werden dauerhaft übernommen.
Abbrechen: Schließt das Popup und die Logikgruppe kann weiter bearbeitet werden.
Zurücksetzen: Alle vorgenommenen Änderungen werden verworfen und auf den zuletzt gespeicherten Zustand zurückgesetzt.

Aufbau Logikbaustein

Jeder Logikbaustein ist einheitlich gestaltet, um eine intuitive Bedienung und schnelle Orientierung zu ermöglichen.

Visuelle Elemente eines Bausteins
Kopfbereich: Zeigt das Symbol und den Namen des Bausteins zur schnellen Identifikation.
Eingänge: Befinden sich auf der linken Seite und werden durch Anschlusspunkte dargestellt. Sie dienen dem Empfang von Signalen anderer Bausteine.
Ausgänge: Befinden sich auf der rechten Seite und leiten Signale an andere Bausteine weiter.
Statusanzeige: Im Ansichtsmodus zeigen Bausteine ihren aktuellen Status oder Wert an, was eine schnelle Funktionskontrolle ermöglicht.
Fehlerhinweise: Konfigurationsfehler oder fehlende Verbindungen werden durch visuelle Hervorhebungen kenntlich gemacht.

Farb- und Textkennzeichnung der Ein- und Ausgänge

Ansichtsmodus
Im Ansichtsmodus steht eine kompakte, auf aktuelle Zustände fokussierte Darstellung mit reduziertem Funktionsumfang sowie einer Echtzeit-Anzeige aktiver Statuswerte im Vordergrund.
Für alle Ein- und Ausgänge werden Zusatzinformationen wie Invertierung und Fixwerteinstellung durch (I) bzw. -fix vor bzw. nach dem Echtzeitwert angezeigt

Boolesche Werte (wahr/falsch)
Grün oder Rot, wenn verbunden oder ein Fixwert gesetzt ist
Ausgeblendet, wenn keine Verbindung und kein Fixwert vorhanden ist

Numerische Werte
Grün: Eingang oder Ausgang ist verbunden oder ein Fixwert wurde definiert
Ausgeblendet: Keine Verbindung und kein Fixwert wurde definiert

Text-/String-Werte
Grün: Eingang oder Ausgang ist verbunden oder ein Fixwert wurde definiert
Ausgeblendet: Keine Verbindung und kein Fixwert wurde definiert

Bearbeitungsmodus
Im Bearbeitungsmodus wird eine erweiterte Darstellung mit zusätzlichen Elementen zur Konfiguration und Verbindung der Bausteine angezeigt.

Farbkennzeichnung der Ein- und Ausgänge (unabhängig vom Datentyp)
Rot: Kein Eingang oder Ausgang ist verbunden und kein Fixwert gesetzt
Grau: Eingang oder Ausgang ist verbunden oder ein Fixwert ist gesetzt

Bedienung des Logikbausteins

Logikbaustein hinzufügen

  • Bearbeitungsmodus aktivieren, indem auf den Bearbeiten-Button geklickt wird.
  • Die Bibliothek über den Hinzufügen-Button (+) öffnen.
  • Gewünschten Baustein aus der Bibliothek auf die Arbeitsfläche ziehen.
  • Der Baustein wird automatisch am Raster ausgerichtet und ist bereit zur Konfiguration.
  • Während des Hinzufügens zeigt ein Ladeindikator den Fortschritt an, bis der Baustein vollständig erstellt ist.
  • Der Systemwert-Baustein erfordert die Auswahl einer bestimmten Systemeigenschaft. In diesem Fall öffnet sich ein Auswahlfenster.

Bausteine konfigurieren

  • Jeder Logikbaustein außer dem Systemwert-Baustein verfügt über spezifische Eigenschaften, die konfiguriert werden können.
  • Auf einen Baustein klicken, um ihn auszuwählen und das Operator Panel zu öffnen.
  • Werte nach Bedarf anpassen. Änderungen werden automatisch übernommen.
  • Rechtsklick auf einen Baustein zeigt ein X-Symbol über das der Baustein gelöscht werden kann an.

Verbindungen zwischen Bausteinen erstellen
Logikbausteine kommunizieren über Verbindungen zwischen Ausgängen und Eingängen:

  • Auf einen Ausgang (rechte Seite) eines Bausteins klicken und die Maustaste gedrückt halten.
  • Die Verbindung zu einem Eingang (linke Seite) eines anderen Bausteins ziehen.
  • Maustaste loslassen, um die Verbindung zu erstellen.
    Verbindungen werden nur hergestellt, wenn die Datentypen kompatibel sind.

Mehrfachauswahl, Duplizieren und Einfügen
Die neue Logikansicht unterstützt die Auswahl mehrerer Bausteine gleichzeitig sowie das einfache Duplizieren und Einfügen:

  • Maustaste lange gedrückt halten, um den Mehrfachauswahlmodus zu aktivieren.
  • Gewünschte Bausteine anklicken, um sie aus- bzw. abzuwählen. Ausgewählte Bausteine werden hervorgehoben.
    Mit mehreren ausgewählten Bausteinen lassen sich Gruppenoperationen durchführen:
    Duplizieren: Alle ausgewählten Bausteine inklusive ihrer Verbindungen können über den Duplizieren-Button (oben rechts) oder per Strg+D eingefügt werden.
    Kopieren und Einfügen: Alternativ lassen sich Bausteine mit Strg+C kopieren und mit Strg+V einfügen.
    Eingefügte Bausteine werden versetzt platziert und behalten ihre Eigenschaften. Bestehende Verbindungen zwischen kopierten Bausteinen werden ebenfalls übernommen.
Beispiele

Feuchtigkeitssteuerung für das Badezimmer

Die Belüftung soll bei Überschreiten eines definierten Wertes gestartet werden.
Dazu werden 3 Bausteine benötigt.
Die Luftfeuchtigkeit des Badezimmers muss über einen Systemwert angelegt werden.
Der Ausgang dieses Werts wird mit einem Vergleicher, der im Operator Panel auf Typ größer eingestellt werden muss, verbunden. Der Vergleichswert kann entweder mit einem weiteren Nummernwert des Systems, oder wie in diesem Beispiel als Fixwert 80, definiert werden. Um kleinere Schwankungen auszugleichen wird die Hysterese auf 2 gestellt.

Weitere Informationen

Ausführungsreihenfolge
Die Ausführungsreihenfolge der Logikbausteine wird automatisch basierend auf ihrer Position in der Zeichenfläche bestimmt:
Bausteine werden von oben nach unten und von links nach rechts ausgeführt.
Die Reihenfolge kann durch Verschieben der Bausteine beeinflusst werden.
Eine korrekte Reihenfolge ist entscheidend, insbesondere bei voneinander abhängigen Bausteinen.

Fehlerbehebung und Bewährte Praktiken
Zyklische Abhängigkeiten: Verbindungen vermeiden, die zu Endlosschleifen führen können.
Fehlende Verbindungen: Alle erforderlichen Eingänge sollten korrekt verbunden sein.
Dokumentation: Aussagekräftige Namen verwenden, um die Logik nachvollziehbar zu gestalten.
Schrittweises Testen: Die Logik in einzelnen Schritten prüfen, um Fehler frühzeitig zu erkennen.
Minimale Bausteinanzahl: Nur notwendige Bausteine einsetzen.
Reduzierung unnötiger Verbindungen: Jede Verbindung erzeugt Rechenaufwand – nur relevante Verbindungen erstellen.

Update-Änderungen in der mobilen Ansicht

Es können jetzt pro Ausgang mehrere Verknüpfungen erstellt werden.

Die Zeitmessung bietet zusätzliche Ausgänge an.

Logic Elements

Elements are all logic elements that you can add to a logic program (AND, OR, etc.)

Create

To create a logic element, you must first be located in the logic program. If not, open the logic program and select the item “edit logic” in the parameter panel. Then add new logic elements to the program using “add function”. To do this, click on the corresponding element.

Element Colour

If a logic element has an error, or if it is simply not activated, then you can recognize this due to the colour of the element.

Green
The element is working fine.

Orange
The output of this element is being simulated.

Grey
The element does not have a fault, but it is deactivated.

Red
The element has a fault: either an input has no value, or the output it is linked to no longer exists.

Connecting Elements

The operator panels for each logic element (except for data elements) are all constructed using the same principle. The first item is the setting (if available), then the inputs, then the output.

This shows you the selection of an input.

The button “select” lets you select the output of a different logic element that you wish to connect to this input.

The checkbox under “invert” lets you invert the input (if it is of type bool).

The checkbox under “fixed value” lets you allocate a fixed value to the input. This means that if you activate this checkbox, the type bool displays a checkbox in the centre with the text “value”. The state of the input can be controlled using this value. If you activate this checkbox for an input of data type number or string, then an input field appears where you can enter the desired value.

Data Elements

Data elements are intermediate stores for values. This means that data elements can be described by other logic elements by selecting this data element at the output (however only if both are of the same type). Data elements can also be linked with inputs of other logic elements. Every data element has the option “parameter” in the operator panel. If you have activated this option, then you can see this data element in the operator panel of the corresponding logic group and you can change it from there. This has the advantage that you do not always have to have the logic program open to change a value. Parameters also means that the value of a data element remains even if the controller were to fail.

You can change the value of any data element via the object panel. You can do this on the left-hand side of the object panel for types bool and number, and on the right-hand side via the input field for type string.

AND

The element “AND” is a classical AND operator. This means the output is set to true as soon as ALL inputs are true. This element can have between 2 and 6 inputs. The number of inputs can be changed via the operator panel using the buttons “add pin” and “remove pin”.

Compare

The compare function works by comparing the values present at the two inputs and switches the output accordingly.

You can change the following settings in the operator panel:

Type
Select the type of comparison

Hysteresis
If you require hysteresis, you can define it here.

Sample time
This is the time for which the comparison must be fulfilled for the output to be switched to true.

OR

The element “OR” is a classical OR operator. This means the output is true as soon as at least one input is true. This element can have between 2 and 6 inputs. The number of inputs can be changed in the operator panel using the buttons “add pin” and “remove pin”.

Time Relay

The time relay lets you delay an output switching on or off, or leave it switched on for a certain time.

The time relay has two types that you can configure under “select used times”.

Delay switching on/off
If the input is true, the output is only set to true after the selected ON time delay. If the input jumps from true to false, the output is set to false after the selected OFF time delay.

Switch on delay and duration
This enables the option “input as flank”. If you have not activated this option, then the input must be true for at least the switch on delay time in order for the output to be set true for the defined duration and after this duration (independently of the input) reset to false. If you have activated this option then a flank is sufficient on the input and the output is set to true for the defined duration and then reset to false.

Time Measurement

Time measurement is represented by a stopwatch. Time measurement can be started, stopped and reset via inputs “activated” and “reset”.

If the input “activated” moves from false to true, the stopwatch starts. If the input “activated” moves from true to false, the stopwatch stops, if “auto reset” was NOT activated.

If “auto reset” is activated, then the stopwatch is reset when the input “activated” moves from true to false.
The input “reset” resets the stopwatch. This only works if “auto reset” has not been activated.

Value Allocation

Mit der Wertzuweisung kann ein beliebiger Wert dem Ausgang zugewiesen werden.

The value on the input E1 is written unchanged to the output if “activated” is true.

Bedingung

Der Bedingungsblock ermöglicht es, Werte nur dann zu setzen, wenn definierte Bedingungen erfüllt sind. Sollte keine Bedingung zutreffen kann zusätzlich ein optionaler Standardwert benutzt werden.
Sobald eine Bedingung true ist, werden alle Bedingungen danach ignoriert.

Eingänge:

  1. Standardwert:
    Wert welcher auf den Ausgang A geschrieben werden soll, wenn keine Bedingung zutrifft und die Einstellung Standardwert verwenden aktiviert ist
  • In der mobilen Ansicht kann Standardwert im Operator Panel ausgewählt werden.
  • In der Editor Ansicht muss zuerst rechts oben auf Bearbeiten geklickt werden. Danach kann Standardwert mit dem jeweiligen Block verbunden werden. Durch einen Klick auf den Pin links von Standardwert kann ein Fixwert zugewiesen werden.
  1. Wenn ODER Sonst wenn:
    Hier muss ein boolscher Wert verknüpft werden. Falls dieser Eingang auf true ist, wird der Wert der unterhalb definiert wurde, auf den Ausgang A geschrieben.
  • In der mobilen Ansicht kann Wenn im Operator Panel ausgewählt werden.
  • In der Editor Ansicht muss zuerst rechts oben auf Bearbeiten geklickt werden. Danach kann Wenn mit dem jeweiligen Block verbunden werden. Durch einen Klick auf den Pin links von Wenn kann ein Fixwert zugewiesen werden.
  1. Wert:
    Wert welcher auf den Ausgang A geschrieben werden soll, wenn die Bedingung oberhalb zutrifft
  • In der mobilen Ansicht kann Wert im Operator Panel ausgewählt werden.
  • In der Editor Ansicht muss zuerst rechts oben auf Bearbeiten geklickt werden. Danach kann Wert mit dem jeweiligen Block verbunden werden. Durch einen Klick auf den Pin links von Wert kann ein Fixwert zugewiesen werden.

Es können auch weitere Bedingungen mit Wert hinzufügt oder gelöscht werden, welche dann als Sonst wenn und Wert angezeigt werden.

  • In der mobilen Ansicht im Operator Panel, unter Eingängen mit einem Klick auf Pin hinzufügen oder Pin löschen.
  • In der Editor Ansicht muss zuerst rechts oben auf Bearbeiten geklickt werden. Danach kann dies in der linken unteren Ecke des Blocks mit einem Klick auf das Plus- und Minus-Icon gemacht werden.

Einstellungen:

  1. Standardwert verwenden:
    Wenn true, dann wird sobald keine Bedingung zutrifft, der Wert des Eingangs Standardwert auf den Ausgang A geschrieben.
  • In der mobilen Ansicht kann Standardwert verwenden im Operator Panel unter Eingänge definiert werden.
  • In der Editor Ansicht kann Standardwert verwenden im Operator Panel definiert werden.

Ausgänge:

  1. A:
    Hier können beliebig viele Blöcke verknüpft werden, auf welche der Wert der ersten Bedingung welche true ist, geschrieben werden soll.
  • In der mobilen Ansicht kann A im Operator Panel verknüpft und ein Fixwert vergeben werden.
  • In der Editor Ansicht muss zuerst rechts oben auf Bearbeiten geklickt werden. Danach kann A1 mit den jeweiligen Blöcken verbunden werden. Mit einem Klick auf den Pin rechts von A kann ein Fixwert vergeben werden.
Counter

The counter can increase, decrease or reset a numerical value to 0.

The input “up” increments the counter by one when the input changes from false to true, the input “down” decrements the counter by one and “reset” resets the counter to 0.

Flank Recognition

Flank recognition allows rising and falling edges to be evaluated. This means that if the selected flank appears on the input, then the output is set to true for one cycle and then reset to false.

The type of flank can be selected in the operator panel under the item “settings”.

Function Generator

The function generator enables periodic square wave signals to be generated.

As soon as the input “activated” is true, the function generator is started and generates a periodic square wave signal on the output.

“TOn” can be used to adjust how long the square wave signal is true and “TOff” how long it is false.

Function

A function element is used to carry out mathematical calculations. “A1” must contain the desired calculation.

The variables E1 to E6 can be used for the calculation, e.g. A1 = 2*E1 + E2.
As soon as the input “activated” is active, the calculation will be carried out. The buttons “add pin” and “remove pin” can be used to add up to 6 inputs. The following shows link shows you which operations are possible:

Documentation- Functions(https://developer.mozilla.org/de/docs/Web/JavaScript/Reference/Global_Objects/Math)

Math. Funktion

Mit dem Math. Funktionsblock können vordefinierte mathematische Berechnungen durchgeführt werden.

Folgende Funktionen stehen zur Verfügung:

  • Maximum: Hier können bis zu 6 Eingänge verwendet werden, von denen das Maximum ausgegeben wird
  • Minimum: Hier können bis zu 6 Eingänge verwendet werden, von denen das Minimum ausgegeben wird
  • Absolut: Gibt immer den absoluten Wert des ausgewählten Eingangs zurück
  • Zufallszahl: Liefert einen ganzzahligen Zufallswert zwischen dem ausgewählten Minimum und Maximum, dieser wird immer dann berechnet wenn in einem Zyklus das „Neu berechnen“ Flag auf „true“ gesetzt ist
  • Runden: Rundet den angegebenen Wert, hier kann zusätzlich angegeben werden auf wie viele Kommastellen gerundet werden soll
  • Potenzfunktion: Führt eine Potenzfunktion aus, wobei sowohl die Basis als auch der Exponent als Eingang definiert werden können
  • Quadratwurzel: Führt die Quadratwurzel auf den Eingang aus
  • Summe: Bildet die Summe aus bis zu 6 Eingängen
  • Mittelwert: Bildet den Mittelwert aus bis zu 6 Eingängen
  • Exponentialfunktion: Bildet die Exponentialfunktion zum angegebenen Exponent
  • Logarithmus zur Basis x: Führt den Logarithmus auf den Eingang aus, wobei die Basis angegeben werden kann
  • Logarithmus zur Basis e: Führt den Logarithmus auf den Eingang aus, wobei die Basis immer e beträgt
PI Controller

This is a clocked PI controller where you supply demand value, actual value and clock.

The settings for the PI controller are located in the parameter panel.

Reset

For as long as the input is true, the output of the reset element will be set to false.

SR Flip Flop

The SR flip flop is used to set and reset an output. If the input “set” is true, then the output is true. If the input “reset” is true, the output is false. If both inputs are true, then the output is false. If both inputs are false, the output is stored, meaning it remains in this state until the input is true again.

Set

For as long as the input is true, the output of the set element will be set to true.

Text Block

The text block is used to create any text string you want.

1 to 6 inputs (E1 – E6) can be created using the buttons “add pin” and “remove pin” and the text from these inputs are then strung together.

For example, if the text for E1 is “It is now ” and the text for E2 is the current time (use the button “select” and under “system” then “time”), then the following text string will be created “It is now 17:00”.

Examples

WC Ventilation

Task
If the light in the WC is switched on, then the ventilation should be switched on 15 seconds later (the ventilator must be connected to a digital output) and run for one minute after the light has been switched off. If the light is switched off before the ventilator is switched on, the ventilator should not be activated.

Solution
First open the app “logic” and create a logic program via “add program”.

Give the logic program the name WC-ventilation and select the room WC.

Open the logic program via the button “edit”. Use the “add function” to add the function time relay. This relay is red, meaning that it isn’t yet working, because there are no inputs.
Now open the time relay. Since the output should be switched on after 15 seconds, you will need a delay of 15 seconds. Change the switch on delay to a fixed value and enter the value 15. Do the same for the switch off delay, except instead of 15, use the value 60, since the ventilation is only meant to run for 1 minute (= 60 seconds) after the light has been switched off.

Now you need to link inputs and outputs. Select input E1 using the button “select” and navigate to the lights, select the WC light and select “light on”. In the object panel of the time delay, you can now see the current value of the light and how it changes when the light is switched on and off. Now all you need to do is connect the output of the time relay with the digital output. To do this, click on “select” under “output” and navigate to the digital outputs. Once there, select the desired output and click on “set value”.

Now you can test your WC ventilation and see if everything is working fine.

Light Transformer

Task
There are 4 lights and 1 light transformer available. The light transformer is connected to a digital input. As soon as at least one light is switched on, the light transformer must be switched on. If no lights are switched on, the light transformer must also be switched off.

Solution
The first thing to do is open the app “logic” and create a logic program via “add program”.
Give this logic program a name “light-trans”.
Next, open the logic program using the button “edit”. Use the button “add function” to add an OR. This OR is red meaning that it is not currently functioning, because it has no inputs.

Now open the OR and add two inputs using the button “add pin”. These four inputs must now be linked with the four lights via the button “select” by selecting “light switched on” for each light. The OR is now green, because all inputs are linked. Finally, you need to connect the digital output of the transformer with the OR. Do this by clicking on “select” under “output”, open the digital output there and select “set value” for the desired digital output.

The logic should now work as desired.

Ventilation Control

Task
You measure humidity in a room and want to switch on the ventilation as soon as the humidity has reached a certain value.

Solution
To do this, the humidity sensor must be connected to an analog input of an analog module and configured accordingly (to do this, see chapter “Analog Input”). The ventilation must be connected to the output of a digital module.

Next, create a logic program in the app “logic” using “add program”. Give the program a meaningful name (e.g. fan control) and if wish, allocate a room. Then open the parameter panel and select “edit” under “edit logic”. Insert a compare function via “add function”.

Now open the operator panel of the compare function. Under the item “settings”, first select for “type” the value “greater than” (since the fan is to be switched on when the humidity is GREATER than a certain value). You can configure the hysteresis for the compare function as you feel is necessary. In this example, select 5 for the hysteresis. The sample time can be left at 0. Now the compare function is correctly configured.

The inputs and output now need to be connected. Select the analog input you connected the humidity sensor to under “inputs” for “E1”. For “E2” enter the value above which the fan is to be switched on. In this example select 80. Now select the digital output you connected the fan to using the button “select” under “output”.

The ventilation control is now complete. If you want, you can change the hysteresis and the sample time as you require.

Szenen

Die Logik bietet folgende Auslöser für Szenen (wenn ...):

  • (Datenbaustein Zahl): Zählerstand wurde vergrößert: Der Wert im Datenbaustein wurde erhöht
  • (Datenbaustein Zahl): Zählerstand wurde verkleinert: Der Wert im Datenbaustein wurde verringert
  • (Datenbaustein Text): Text wurde geändert: Der Text im Datenbaustein wurde geändert
  • (Datenbaustein Bool): Steigende Flanke: Der Wert wurde auf logisch 1 (true) gesetzt
  • (Datenbaustein Bool): Fallende Flanke: Der Wert wurde auf logisch 0 (false) gesetzt

Die Logik bietet folgende Funktionen für Szenen (dann ...):

  • (Datenbaustein Zahl): Wert setzen: Der Wert im Datenbaustein kann beliebig manipuliert werden
  • (Datenbaustein Text): Wert setzen: Der Text im Datenbaustein kann beliebig manipuliert werden
  • (Datenbaustein Bool): Aktivieren: Der Wert wird auf logisch 1 (true) gesetzt
  • (Datenbaustein Bool): Deaktivieren: Der Wert wird auf logisch 0 (false) gesetzt
  • (Logikprogramm): Logikprogramm aktivieren: Das Logikprogramm wird aktiviert
  • (Logikprogramm): Logikprogramm deaktivieren: Das Logikprogramm wird deaktiviert

Szenenfunktionen für Bausteine (wie z.B.: Datenbaustein Zahl, Text,...) sind unter dem Reiter „Logik“ und der entsprechenden Logik zu finden. Szenenfunktionen für das Logikprogramm selbst sind unter dem Reiter „Apps“ und der App „Logik“ zu finden.

Detector

The "Detector" app allows a digital input to be used for alarms or notifications. For example, it can be used to integrate devices such as fire detectors into the Smart Building Automation system.

The Detector app is located under "All Apps" – "Detector".

Create

To create a "detector", a Schrack Smart Building Automation digital module, like the "D1180" or "D1344", with a digital input is required. Then, follow these steps:

Open the 'digital inputs' app under 'all apps'.

Select the digital input that will be used as a detector.

Open the settings of the selected digital input and set the mode to 'detector'.

The digital input is now configured as a detector and is listed in the 'detector' app.

Configuration

Each Detector allows you to configure the triggered alarms. Here you will find the description about all available options.

Type
This are pre configured settings for different use cases. Each one comes with a predefined notification text, settings and specific icon.

Alarm after
Defines the timespan for which a signal has to be active on the digital input to trigger an alarm.

Notification
Here you can choose to receive a notification once an alarm gets triggered.

Notification text
Set the text you want to see in the notification.

Alarm must be acknowledged
If this option is active, an active alarm has to be manually terminated instead of ending once the input signal stops.

Reserve (hide in visualization)
Once active, the Detector will be hidden in the visualization.

Icon
Defines which image should be used for this Detector.

Alarm Output
You can choose a digital output, which will be triggered in case of an alarm, here.

Mode
Here, the Digital Input which is used for this Detector can be switched back to another mode.

Simulation on
Activates the simulation and allows you to set a value via the setting 'Simulation Value'. Attention: If the simulation is active, real values are ignored!

Simulation Value
Change the simulated value with this setting.

Operation

After you changed a Digital Input into a Detector, it will react to incoming signals and trigger an alarm, depending on its configuration.

A detector will display if his input is currently active and if it is triggering an alarm.

Szenen

Der Melder bietet folgende Auslöser für Szenen (wenn ...):
- Alarm wurde ausgelöst: Der Alarm des Melders wurde ausgelöst
- Alarm wurde beendet: Der Alarm des Melders wurde beendet

Der Melder bietet folgende Funktionen für Szenen (dann ...):
- Alarm quittieren: Der Alarm des Melders wird quittiert

Miele

Die Miele App ermöglicht die Anbindung des neusten Miele Einbau-Kaffeevollautomats.

Weitere Informationen folgen in Kürze.

Mixer Circuit Control

The “mixer circuit control” app is an external temperature heating control loop. The “mixer circuit control” is used to configure and control 3-way heating mixer valves.

These functions are located under “all apps” – “mixer circuit control”.

Operation

Click on the element “add mixer control” to create a new mixer circuit controller. The next step is to give your mixer circuit control a name, and then you can continue with the configuration.

The operator panel displays a schematic of the control. This diagram shows you whether the pump is on (screw in the pump is green and rotates) or off. Displayed adjacently is the current temperature of the feed line and to the right the current position of the mixer valve and whether it is open or closed.

All relevant values pertaining to your mixer circuit control are displayed below this.

If your mixer valve is unreferenced, i.e. the current position of the valve is unknown, then the button “execute reference” is displayed. Clicking on it closes the valve completely; hence the current position is known. The mixer circuit control must be fully configured before a reference can be executed.

Heating Curve

The heating curve allows you to adjust the desired temperature of the feed line as a function of the outside temperature.

There are pre-defined curves you can select from using “select curve type”. If there is no pre-defined curve that entirely suits your needs, then you can edit the pre-defined curves by clicking on “edit”. The selection then jumps to “user-defined”. If you wish to save your curve, click on “save”. Saved curves can be deleted using “delete”. When selecting points, you are limited on the one hand by the minimum and maximum feed line temperature, and on the other by the previous and subsequent point. For example, the point at 10 °C outside temperature cannot have a lower feed line temperature than the point at 15°C and a higher temperature than the point at 5°C.

If the outside temperature reaches a value outside of the curve, then the curve is continued horizontally. This means if the curve were to end on the left-hand side at an outside temperature of +20°C with a corresponding feed line temperature of +22°C, then the feed line temperature for outside temperatures higher than +20°C will remain +22°C.

To be able to process outside temperatures higher than +20°C, the cooling operation must be activated under “all apps” – “settings” – “room climate”. Warning! Cooling operation may only be activated if the heating is really able to cool, since in cooling mode, the mixer outputs are switched exactly the opposite way.

Feed Line Temperature Limitation

You can define your minimum and maximum feed line temperatures here.

Rücklauftemperatur Begrenzung

Über diese Einstellung können Sie die maximale Temperatur, die im Rücklauf vorhanden sein darf, regulieren. Wird die eingestellte Temperatur überschritten, wird das Ventil auf diese Temperatur geregelt, bis die Temperatur wieder unter dem vorgegebenen Wert liegt.

Mixer Parameters

Enter the runtime for the mixer valve in seconds according to the manufacturer in “manufacturer mixer valve runtime [s]”. If the value you entered was correct, then you must now click on the button “execute reference run”. Please note that you must have previously correctly set the inputs and outputs.

The field “overrun time” lets you how much longer in percent the mixer output remains switched on when completely open or closed. This guarantees that the mixer is subsequently really completely open or closed.

Since a mixer valve normally requires longer to close than to open, you can use the “multiplier mixer closed” to define how much longer the valve needs to close than open.

Calibration Run

Since there is always a certain error when opening and closing the valve, a calibration run must be run daily. All you have to do is set the desired time for this to occur and the rest is done automatically.

Inputs

Feed line actual temperature
Select the input here that measures the actual temperature of the feed line.

Outside temperature
Select here the input used to measure the outside temperature. The standard setting is located in “system” – “house status” – “outside temperature”.

Release
Select the main switch for the mixer control. This input is used to activate or deactivate the entire control.

Outputs

Valve Type
The used valve type is chosen here. The options are analog with "0-10V signal" and digital "open/close signal".

Valve
(With valve type "0-10V signal")
Select the analog output, which will be used for the valve control.

Mixer open
(With valve type "Auf/Zu signal")
Select here the output used to open the mixer valve.

Mixer closed
(With valve type "Auf/Zu signal")
Select here the output used to close the mixer valve.

Pump
Select the output used to connect the mixer pump.

Fault
Select an output to be switched if there is a fault.

Pumpe deaktivieren

In diesem Abschnitt können Sie die automatische Abschaltung der Pumpe einstellen, wenn von Ihnen festgelegte Temperaturen über- oder unterschritten werden.

Absenkbetrieb

Hier kann der Absenkbetrieb konfiguriert werden. Bei aktiviertem Absenkbetrieb wird die Vorlauftemperatur der Heizkurve um den eingestellten oder verknüpften Wert korrigiert. Im Heizbetrieb wird der Wert subtrahiert im Kühlbetrieb addiert. Der Absenkbetrieb kann zum Beispiel mit dem Hausstatus verknüpft werden, dadurch wird die Heizkurve automatisch an die Hausbelegung angepasst.

Einstellungen

Unter dem Reiter „Einstellungen“, können folgende Änderungen an der Mischerregelung vorgenommen werden:

  • Mischer permanent öffnen: Den Mischer dauerhaft öffnen
  • Mischer permanent schließen: Den Mischer dauerhaft schließen
  • Alle Pumpen permanent einschalten: Alle Pumpen dauerhaft einschalten
  • Alle Pumpen permanent ausschalten: Alle Pumpen dauerhaft ausschalten
  • Fehler-Ausgang permanent einschalten: Den Fehler-Ausgang dauerhaft einschalten
  • Fehler-Ausgang permanent ausschalten: Den Fehler-Ausgang dauerhaft ausschalten

Extended Configuration

The extended configuration allows you to configure all the components of your mixer control extra. Simply click on “edit”. Exercise caution, particularly when adjusting the controller parameters.

Below this, you can adjust the sample time and minimum error.

Sample time
This is the time period when a new position of the valve is calculated (standard 10s).

Minimum error
The position of the valve is only adjusted if there is a difference between desired and actual temperature of the feed line. If the difference (error) is larger than this value, then the position of the valve is changed.

Activate notification
If you wish to receive a notification of a fault condition, then activate this option.

Logik

Das Raumklima bietet folgende Möglichkeiten für die Verwendung in Logiken:

  • Mischer permanent öffnen: Den Mischer dauerhaft öffnen
  • Mischer permanent schließen: Den Mischer dauerhaft schließen
  • Alle Pumpen permanent einschalten: Alle Pumpen dauerhaft einschalten
  • Alle Pumpen permanent ausschalten: Alle Pumpen dauerhaft ausschalten
  • Fehler-Ausgang permanent einschalten: Den Fehler-Ausgang dauerhaft einschalten
  • Fehler-Ausgang permanent ausschalten: Den Fehler-Ausgang dauerhaft ausschalten
  • Ventil permanent setzen: Dem Ventil des Heizkreises, permanent einen Wert zuweisen

Systemmeldungen

Folgende Systemmeldungen können von der Mischerregelung ausgelöst werden:

Achtung! Es wurden nicht alle Ausgänge verknüpft

Diese Warnung sagt aus, dass im Parameter Panel unter Ausgänge nicht alle erforderlichen Ausgänge verknüpft wurden.

Diese Warnung wird sofort erkannt.

In diesem Zustand wird bereits geregelt, jedoch werden die nicht verknüpften Ausgänge nicht angesteuert.

Im Object Panel wird ein gelbes Fragezeichen angezeigt.
Im Operator Panel wird die Warnung angezeigt.

Mischer öffnet permanent

Diese Warnung sagt aus, dass der Mischer so eingestellt wurde, dass dieser permanent öffnet.

Die Warnung wird sofort erkannt.

In diesem Zustand wird der digitale Ausgang zum Öffnen des Mischers dauerhaft eingeschaltet.

Im Object Panel wird ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird die Warnung angezeigt.

Mögliche Ursachen sind:

  • Die Einstellung Mischer permanent öffnen unter Einstellungen im Parameter Panel ist gesetzt
  • Eine Logik beschreibt den Wert

Mischer schließt permanent

Diese Warnung sagt aus, dass der Mischer so eingestellt wurde, dass dieser permanent schließt.

Die Warnung wird sofort erkannt.

In diesem Zustand wird der digitale Ausgang zum Schließen des Mischers dauerhaft eingeschaltet.

Im Object Panel wird ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird die Warnung angezeigt.

Mögliche Ursachen sind:

  • Die Einstellung Mischer permanent schließen unter Einstellungen im Parameter Panel ist gesetzt
  • Eine Logik beschreibt den Wert

Pumpen sind permanent eingeschaltet

Diese Warnung sagt aus, dass die Pumpen so eingestellt wurden, dass diese permanent eingeschaltet sind.

Die Warnung wird sofort erkannt.

In diesem Zustand werden die digitalen Ausgänge der Pumpen dauerhaft eingeschaltet.

Im Object Panel wird ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird die Warnung angezeigt.

Mögliche Ursachen sind:

  • Die Einstellung Alle Pumpen permanent einschalten unter Einstellungen im Parameter Panel ist gesetzt
  • Eine Logik beschreibt den Wert

Pumpen sind permanent ausgeschaltet

Diese Warnung sagt aus, dass die Pumpen so eingestellt wurden, dass diese permanent ausgeschaltet sind.

Die Warnung wird sofort erkannt.

In diesem Zustand werden die digitalen Ausgänge der Pumpen dauerhaft ausgeschaltet.

Im Object Panel wird ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird die Warnung angezeigt.

Mögliche Ursachen sind:

  • Die Einstellung Alle Pumpen permanent ausschalten unter Einstellungen im Parameter Panel ist gesetzt
  • Eine Logik beschreibt den Wert

Fehler-Ausgang ist permanent eingeschaltet

Diese Warnung sagt aus, dass der Fehler-Ausgang so eingestellt wurde, dass dieser permanent eingeschaltet ist.

Die Warnung wird sofort erkannt.

In diesem Zustand wird der digitale Ausgang für den Fehler dauerhaft eingeschaltet.

Im Object Panel wird ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird die Warnung angezeigt.

Mögliche Ursachen sind:

  • Die Einstellung Fehler-Ausgang permanent einschalten unter Einstellungen im Parameter Panel ist gesetzt
  • Eine Logik beschreibt den Wert

Fehler-Ausgang ist permanent ausgeschalten

Diese Warnung sagt aus, dass der Fehler-Ausgang so eingestellt wurde, dass dieser permanent ausgeschaltet ist.

Die Warnung wird sofort erkannt.

In diesem Zustand wird der digitale Ausgang für den Fehler dauerhaft ausgeschaltet.

Im Object Panel wird ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird die Warnung angezeigt.

Mögliche Ursachen sind:

  • Die Einstellung Fehler-Ausgang permanent ausschalten unter Einstellungen im Parameter Panel ist gesetzt
  • Eine Logik beschreibt den Wert

Ventilwert ist permanent gesetzt

Diese Warnung sagt aus, dass das Ventil auf einen fixen Wert eingestellt wurde.

Die Warnung wird sofort erkannt.

In diesem Zustand wird der analoge Ausgang für das Ventil dauerhaft auf den im Parameter Panel eingestellten Wert gesetzt.

Im Object Panel wird ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird die Warnung angezeigt.

Mögliche Ursachen sind:

  • Die Einstellung Ventilwert permanent setzen unter Einstellungen im Parameter Panel ist gesetzt

Von globaler Heiz-/Kühlumschaltung ausgenommen

Diese Warnung sagt aus, dass die Mischerregelung nicht mit der globalen Heiz-/Kühlumschaltung gesteuert wird, sondern manuell umgeschaltet werden muss.

Die Warnung wird sofort erkannt.

In diesem Zustand bleibt die Mischerregelung im eingestellten Heiz- oder Kühlbetrieb, auch wenn der globale Heiz-/Kühlbetrieb geändert wird.

Im Operator Panel wird die Warnung angezeigt und über die Buttons „Heizen“ und „Kühlen“ kann der Betrieb geändert werden.

Mögliche Ursachen sind:

  • Die Einstellung Von globaler Heiz-/Kühlumschaltung ausnehmen unter Einstellungen im Parameter Panel ist gesetzt

Kalibrierungsfahrt wird gerade ausgeführt

Diese Meldung wird im Operator Panel angezeigt, wenn der Mischer gerade eine Kalibrierungsfahrt durchführt. Das ist nötig um mögliche Fehler, welche beim Öffnen und Schließen des Mischers entstehen können, wieder auszugleichen.

Diese Meldung sagt aus, dass der Mischer gerade eine Kalibrierungsfahrt durchführt. Das ist nötig um mögliche Fehler, welche beim Öffnen und Schließen des Mischers entstehen können, wieder auszugleichen.

Die Meldung wird sofort angezeigt.

In diesem Zustand wird das Ventil einmal komplett geschlossen, um das Ventil neu zu kalibrieren, danach wird wieder mit der gewohnten Regelung fortgefahren.

Im Operator Panel wird die Meldung angezeigt.

Mögliche Ursachen sind:

  • Die tägliche Kalibrierung, welche unter Kalibrierungsfahrt im Parameter Panel eingestellt wurde, ist gerade aktiv
  • Die Kalibrierung wurde manuell über den Button Kalibrierungsfahrt ausführen im Parameter Panel unter Kalibrierungsfahrt gestartet

Achtung: Nicht alle Ein-/Ausgänge wurden verknüpft!

Dieser Fehler sagt aus, dass im Parameter Panel unter Eingänge nicht alle Eingänge und unter Ausgänge nicht alle Ausgänge verknüpft wurden.

Dieser Fehler wird sofort erkannt.

In diesem Zustand kann nicht zuverlässig geregelt werden und die nicht verknüpften Ausgänge werden nicht angesteuert. Sollte ein Fehler-Ausgang verknüpft sein, wird dieser eingeschaltet.

Im Object Panel wird ein rotes X angezeigt.
Im Operator Panel wird der Fehler angezeigt.

Maximale Vorlauftemperatur überschritten

Dieser Fehler sagt aus, dass die maximale Vorlauftemperatur überschritten wurde.

Dieser Fehler wird sofort erkannt bei einer Überschreitung der maximalen Temperatur bei einer Hysterese von 1°C. Sowohl im Heiz- als auch im Kühlbetrieb.

In diesem Zustand wird weiter geregelt, jedoch muss die Fehlerursache eruiert werden. Zudem wird der Fehler-Ausgang eingeschaltet.

Es wird zudem eine Benachrichtigung ausgegeben, falls die Option Benachrichtigung unter Benachrichtigungen aktivieren im Parameter Panel aktiviert wurde.

Im Object Panel wird ein rotes X angezeigt.
Im Operator Panel wird der Fehler angezeigt.

Mögliche Fehlerursache ist ein Defekt oder eine falsche Einstellung am Mischerventil oder der Pumpe.

Minimale Vorlauftemperatur unterschritten

Dieser Fehler sagt aus, dass die minimale Vorlauftemperatur unterschritten wurde.

Dieser Fehler wird sofort erkannt bei einer Unterschreitung der minimalen Vorlauftemperatur bei einer Hysterese von 1°C. Sowohl im Heiz- als auch im Kühlbetrieb.

In diesem Zustand wird weiter geregelt, jedoch muss die Fehlerursache eruiert werden. Zudem wird der Fehler-Ausgang eingeschaltet.

Es wird zudem eine Benachrichtigung ausgegeben, falls die Option Benachrichtigung unter Benachrichtigungen aktivieren im Parameter Panel aktiviert wurde.

Im Object Panel wird ein rotes X angezeigt.
Im Operator Panel wird der Fehler angezeigt.

Mögliche Fehlerursache ist ein Defekt oder eine falsche Einstellung am Mischerventil oder der Pumpe.

Soll-/Istwert Abweichung über Toleranzwert

Dieser Fehler sagt aus, dass die Ist-Vorlauftemperatur zu stark vom Sollwert abweicht.

Dieser Fehler wird erkannt, wenn die Differenz zwischen Ist- und Soll-Vorlauftemperatur länger als die unter Benachrichtigungen eingestellte Zeit um die eingestellte Differenz abweicht.

In diesem Zustand wird weiter geregelt, jedoch muss die Fehlerursache eruiert werden. Zudem wird der Fehler-Ausgang eingeschaltet.

Es wird zudem eine Benachrichtigung ausgegeben, falls die Option Benachrichtigung unter Benachrichtigungen aktivieren im Parameter Panel aktiviert wurde.

Im Object Panel wird ein rotes X angezeigt.
Im Operator Panel wird der Fehler angezeigt.

Mögliche Fehlerursachen sind:

  • Eine inkorrekte Temperatur des zugeführten Mediums
  • Ein Defekt oder eine falsche Einstellung am Mischerventil oder der Pumpe.

Prüfen: Heizanforderung. Mischer aber bereits voll offen.

Dieser Fehler sagt aus, dass der Mischer bereits voll geöffnet wurde, aber weiterhin eine Heizanforderung besteht.

Dieser Fehler wird erkannt, wenn der Mischer bereits voll geöffnet ist, aber über 5 Minuten weiterhin eine Heizanforderung besteht.

In diesem Zustand wird weiter geregelt, jedoch muss die Fehlerursache eruiert werden. Zudem wird der Fehler-Ausgang eingeschaltet.

Es wird zudem eine Benachrichtigung ausgegeben, falls die Option Benachrichtigung unter Benachrichtigungen aktivieren im Parameter Panel aktiviert wurde.

Im Object Panel wird ein rotes X angezeigt.
Im Operator Panel wird der Fehler angezeigt.

Mögliche Fehlerursachen sind:

  • Eine zu niedrige Temperatur des zugeführten Mediums
  • Ein Defekt oder eine falsche Einstellung am Mischerventil oder der Pumpe.

Kühlen ist aktiv, aber dieser Heizkreis kann nicht kühlen

Dieser Fehler sagt aus, dass aktuell auf Kühlbetrieb gestellt ist, die Mischerregelung aber nur im Heizbetrieb regeln kann.

Dieser Fehler wird sofort erkannt.

In diesem Zustand wird nicht geregelt.

Im Object Panel wird ein rotes X angezeigt.
Im Operator Panel wird der Fehler angezeigt.

Fehlerbehebung: wenn auch im Kühlbetrieb geheizt werden soll, dann kann diese Mischerregelung unter Einstellungen im Parameter Panel über Von globaler Heiz-/Kühlumschaltung ausnehmen von der globalen Heizanforderung ausgenommen werden.

Mögliche Fehlerursachen ist, dass die Mischerregelung nur Heizen kann, die globale Heiz-/Kühlumschaltung auf Kühlen gestellt ist und unter Einstellungen im Parameter Panel die Funktion Von globaler Heiz-/Kühlumschaltung ausnehmen deaktiviert ist, obwohl getrennt von der globalen Heiz-/Kühlumschaltung geheizt werden soll.

Heizen ist aktiv, aber dieser Heizkreis kann nicht heizen

Dieser Fehler sagt aus, dass aktuell auf Heizbetrieb umgeschaltet wurde, die Mischerregelung aber nur im Kühlbetrieb aktiv ist.

Dieser Fehler wird sofort erkannt.

In diesem Zustand wird nicht geregelt.

Im Object Panel wird ein rotes X angezeigt.
Im Operator Panel wird der Fehler angezeigt.

Fehlerbehebung: wenn auch im Heizbetrieb gekühlt werden soll, dann kann diese Mischerregelung unter Einstellungen im Parameter Panel über Von globaler Heiz-/Kühlumschaltung ausnehmen von der globalen Heizanforderung ausgenommen werden.

Mögliche Fehlerursachen ist, dass die Mischerregelung nur Kühlen kann, die globale Heiz-/Kühlumschaltung auf Heizen gestellt ist und unter Einstellungen im Parameter Panel die Funktion Von globaler Heiz-/Kühlumschaltung ausnehmen deaktiviert ist, obwohl getrennt von der globalen Heiz-/Kühlumschaltung gekühlt werden soll.

Modbus

Erstellen

Bevor die Kommunikation zwischen dem Smart Building Automation System und einem Modbus Gerät hergestellt werden kann, muss dieses zuerst in dasselbe Netzwerk integriert, oder ordnungsgemäß an eine RS485 Schnittstelle angeschlossen werden.

Zum Hinzufügen eines Modbus Geräts auf die Schaltfläche „Hinzufügen“ klicken.

Nun öffnet sich ein Fenster, in dem ausgewählt werden kann, ob ein Modbus TCP/IP oder RTU Gerät eingebunden werden soll.

Bei der Auswahl „Dynamischer Modbus TCP/IP“ wird eine Gerätevorlage erstellt, in der alle erforderlichen Einstellungen vorgenommen werden können.

Bei der Auswahl „Dynamischer Modbus RTU“ führt ein Assistent Schritt für Schritt durch die Konfiguration des Geräts.

Nach einem Klick auf „Weiter“, kann die Schnittstelle ausgewählt werden, an die das zu konfigurierende Gerät angeschlossen wurde.

Als nächstes können die Baudrate, Parität, die Anzahl der Datenbits und Stoppbits konfiguriert werden. Nach dem Bestätigen dieser Eingaben, wird die gewählte Konfiguration erstellt.

Danach kann die Geräte Adresse des Geräts eingegeben werden.
Achtung: Es dürfen und können nicht zwei Geräte mit derselben Geräte Adresse auf ein und derselben Schnittstelle konfiguriert werden.

Nach Abschluss der Konfiguration werden die vorgenommenen Einstellungen noch einmal zusammengefasst. Sind alle Einstellungen korrekt, kann mit „Weiter“ fortgefahren werden.

Zum Herstellen einer Verbindung mit dem Modbus RTU Gerät muss ein lesbares Holding-Register angegeben werden. Die erforderlichen Informationen sind üblicherweise in der Betriebsanleitung, im Datenblatt oder in anderen Unterlagen des jeweiligen Geräts zu finden. Mit einem Klick auf „Weiter“ wird nach dem konfigurierten Gerät gesucht.

Wurde das Register erfolgreich gelesen, wird der bei der Abfrage gelieferte Wert angezeigt. Anschließend kann die Konfiguration des Geräts abgeschlossen werden.

Konnte keine Verbindung hergestellt werden, kann die Abfrage des ausgewählten Registers erneut durchgeführt werden. Alternativ kann dieser Schritt übersprungen und die Konfiguration des Geräts abgeschlossen werden.

Konfiguration

Nach dem Erstellen eines Geräts sollte zunächst, sofern noch nicht vorhanden, ein Name vergeben und ein Raum zugeordnet werden.

Bei einem TCP-Gerät müssen anschließend unter dem Reiter „Einstellungen“ die Netzwerkadresse (IP, Port) sowie die Slave ID des Modbus Geräts eingetragen werden, um eine Verbindung mit dem Gerät herzustellen.

Bei einem RTU-Gerät sind hier keine weiteren Einstellungen erforderlich.

Als Nächstes werden die gerätespezifischen Informationen zu den les- und schreibbaren Registern benötigt, auf die über die Modbus Schnittstelle des Smart Building Automation Systems zugegriffen werden kann.
Diese Informationen sind den Unterlagen des jeweiligen Modbus Geräts zu entnehmen.

Sobald alle erforderlichen Informationen vorliegen, können die entsprechenden Register angelegt werden. Dazu zum Bereich „Register editieren“ navigieren und „Editieren“ auswählen.

Anschließend öffnet sich die Registeransicht, in der neue Register hinzugefügt oder bestehende Register angepasst werden können.

Es stehen 4 verschiedene Registerarten zur Verfügung:

Coil Status (1 Bit, Lesen-Schreiben: FC=01)
Einzelner Ein-/Ausgang.

Discrete Input (1 Bit, Nur Lesen: FC=02)
Einzelner Eingang.

Holding Register (16-Bit, Lesen-Schreiben: FC=03)
Analoger Ein-/Ausgang.

Input Register (16-Bit, Nur Lesen: FC=04)
Analoger Eingang.

Nach dem Hinzufügen eines Registers, können die Einstellungen bezüglich Adresse und Datentyp im Parameter Panel vornehmen werden.

Jedes Register kann mit einem beliebigen Namen versehen werden. Zusätzlich zum Namen haben die Register ein Eingabefeld „Kategorie“. Werden die Register mit einer Kategorie versehen, so werden die Register anhand der vergebenen Kategorien im Operator Panel des Modbus Geräts angeordnet. Die Sortierung der einzelnen Register folgt dabei der Sortierung der Panels der einzelnen Register.

Im Reiter „Einstellungen“ können Parameter wie Adresse, Format, Datenlänge, Datentyp sowie die Zugriffsart des Registers eingeben werden.

Je nach eingestelltem Format können für das Register unterschiedliche Anzeigeeinstellungen konfiguriert werden.

Wenn zudem bei einem Register der Zugriff „Schreibend“ ausgewählt ist, kann eingestellt werden, ob das Register zyklisch (alle 30 Sekunden) beschrieben werden soll.

Achtung: Welche Register für das jeweilige Modbus Gerät verwendet werden können und welche Konfigurationsdaten (Adresse, Datentyp, Lese-/Schreibzugriff) erforderlich sind, ist den Unterlagen des Geräts zu entnehmen.

Unter den Parametern bei Holding Register mit dem Format „Wert als Zahl“ können folgende Einstellungen vorgenommen werden:

Minimum und Maximum setzen (nur schreibende Holding-Register): Den Wertebereich einstellen, welchen der Wert haben darf, der auf das Register geschrieben wird

Anzeigeeinstellungen

  • Einheit: Einheit, welche hinter dem Wert angezeigt wird
  • Kommastellen: Wie viele Kommastellen angezeigt werden sollen
  • Multiplikator: Mit welchem Faktor der empfangene/zu sendende Wert multipliziert werden soll

Einstellung für schreibende Werte (nur für schreibende Holding-Register aktiviert)

  • Darstellungsart: Hier kann zwischen einem Slider und einem Eingabefeld gewählt werden, um den Wert einzustellen, der geschrieben werden soll
  • Genauigkeit: (nur beim Slider) Die Genauigkeit, welche der Slider haben soll
  • Modus: Ob alle Register, die diesem Register angehören, auf einmal geschrieben werden soll, oder nacheinander

Wird bei Holding Registern das Format „Wert als Option“ ausgewählt, können Alias-Namen für Zahlenwerte festgelegt werden. Somit können Zahlenwerte beliebig benannt werden. Als Wert wird in der Bedienung dann mittels der festgelegten Optionen anstatt der Zahlenwerte gearbeitet.

Ist der Wert eines Holding oder Input Registers Bit-Kodiert, so dass jedes Bit eines Registers einen binären Status darstellt, kann im Register das Format „Einzelne Bits“ ausgewählt werden.

Wird dieses Format ausgewählt, können die einzelnen Bits benannt und bei Bedarf invertiert werden. Zusätzlich kann jedes Bit je nach Verwendung ein- oder ausgeblendet werden.

Die Bits sind in weiterer Folge auch in der Logik oder Szenen verwendbar.

Byte-Reihenfolge

  • Hier kann die Reihenfolge der Bytes eingestellt werden, mit welcher der angezeigte Wert zusammengesetzt werden soll

Debug

  • Hier ist ersichtlich, wie oft und wann die letzten Daten empfangen/gesendet wurden
  • Das gleiche gilt für die Anzahl der Fehler
  • Am Ende, werden noch die zuletzt empfangenen Daten angezeigt

Bedienung

Im Operator Panel ist als Erstes ersichtlich, ob eine Verbindung mit dem Gerät besteht oder nicht.

Unterhalb befindet sich ein Textfeld, in dem wichtige Informationen vom Benutzer eingetragen werden können.
Achtung: Bei einem Modbus RTU Gerät kann diese Änderung nur im Parameter Panel vorgenommen werden!

Als nächstes werden die Statuswerte aller lesbaren Register angezeigt und Bedienelemente für alle schreibenden Register angeboten. Nach der Konfiguration kann das Gerät hier gesteuert und ausgelesene Werte kontrolliert werden.

Im Parameter Panel können wie gewohnt der Name und Bereich des Geräts geändert werden.

Unter dem Reiter „Einstellungen“ ist der Status des Geräts ersichtlich und es kann die IP-Adresse, der Port sowie die Slave ID geändert werden.

Zudem haben Sie die Möglichkeit die Kommunikation mit dem Gerät zu aktiveren und deaktivieren.

Bei einem Modbus TCP Gerät kann auch ausgewählt werden, ob die Benachrichtigungen angezeigt werden sollen oder nicht.

Mit einem Klick auf den Button „Editieren“, können Register hinzugefügt, gelöscht und bearbeitet werden.

Wenn Sie alle Einstellungen vorgenommen haben und Sie diese sichern wollen, können Sie das Gerät exportieren und die entsprechende zip-Datei herunterladen. Sollten Sie nun ein ähnliches Gerät in das System einbinden wollen, brauchen Sie nur ein neues Gerät erstellen und diese zip-Datei importieren. Somit hat das Gerät genau die Einstellungen, welche in der exportierten Datei gespeichert wurden. Damit erspart man sich viel Zeit und muss nicht jedes Mal erneut die gleichen Register konfigurieren.

Es ist auch möglich, unter dem Reiter „Anzeigewert“, ein lesendes Register auszuwählen, dessen Wert im Object Panel des Geräts angezeigt werden soll. Wenn hier „Kein Anzeigewert“ ausgewählt ist, wird stattdessen der Bereich angezeigt.

Schlussendlich kann auch noch das Icon, sowie die Farbe des Geräts nach Belieben geändert werden.

Je nach Registertyp und gewählten Anzeigeeinstellungen werden im Operator Panel des Registers die aktuellen Werte angezeigt. Wird beispielsweise bei einem Holding Register das Format „Werte als Bits“ eingestellt, so werden die einzelnen konfigurierten Bits dementsprechend aufgelistet.

Im Operator Panel wird zusätzlich zum Anzeigeformat auch berücksichtigt, ob es sich um ein lesendes oder schreibendes Register handelt.

Sind bei einem Holding Register mit eingestelltem Format „Wert als Optionen“ nicht mehr als 4 Optionen konfiguriert, so werden diese als Buttons im Operator Panel angezeigt. Bei mehr als 4 Optionen kann der Wert mittels einer Auswahlliste geändert werden.

Szenen

Die Modbus App bietet folgende Auslöser für Szenen (wenn ...):

  • Getrennt: Das Modbus Gerät wurde getrennt
  • Verbunden: Das Modbus Gerät wurde verbunden

Die Modbus App bietet folgende Auslöser für Szenen (dann ...):

  • Register schreiben (nur für RTU Geräte): Wert wird auf das ausgewählte Register geschrieben

Logik

Die Modbus App bietet folgende Möglichkeiten für die Verwendung in Logiken (nur für RTU Geräte):

  • Wert: Empfangener Wert des Registers
  • Wert schreiben: Wert wird auf das ausgewählte Register geschrieben

Musik

Wenn Sie ein angeschlossenes Audiomodul besitzen, können Sie es mit Hilfe der App „Musik“ steuern. Jedes Audiomodul, bietet 4 einzelne Ausgänge an denen Sie Lautsprecher anschließen können, welche dann über die „Musik“ App konfiguriert werden können. Außerdem ermöglicht Ihnen dieses Modul die Wiedergabe von Musik aus bis zu 4 verschiedenen Quellen.

„Sie finden die Anwendung unter 'Alle Apps' - 'Musik'.“

Konfiguration

Sobald ein neues Audiomodul an das Smart Building Automation System angeschlossen wurde, kann bereits mit der Konfiguration der Lautsprecher und Quellen begonnen werden. Dazu sind folgende Schritte zu befolgen:

Bevor die einzelnen Quellen und Lautsprecher konfiguriert werden können, sollten zunächst einige grundlegende Einstellungen für das Audiomodul vorgenommen werden.

Dazu unter „Alle Apps“ - „Hardware“ das entsprechende Audiomodul auswählen.

Die zugehörigen Einstellungen können durch einen Klick auf den Namen des Moduls geöffnet werden.

Zunächst muss festgelegt werden, wie die Lautsprecher verwendet werden sollen. Zur Auswahl stehen Mono- oder Stereogruppen. Alternativ können alle 4 Lautsprecherausgänge zu einer gemeinsamen Gruppe zusammengefasst werden.

Abhängig von der gewählten Einstellung werden die entsprechenden Lautsprecher in der Musik-App angezeigt.

Um eine Beschädigung der Lautsprecher durch zu hohe Lautstärken zu vermeiden, können hier die maximale und die minimale Lautstärke für alle angeschlossenen Lautsprecher festgelegt werden.

Bedienung

„Haben Sie alle Einstellungen durchgeführt können Sie bereits zu 'Alle Apps' - 'Musik' navigieren, wo Sie nun alle verfügbaren Quellen sowie Lautsprecher wiederfinden.“

Quellen

Jedes Audiomodul verfügt über vier verschiedene Quellen, welche Ihren Lautsprechern zugewiesen werden können. Während „FM-Radio“ und „Aux“ fest vorgegeben sind, können Sie für die übrigen zwei zwischen mehreren Optionen wählen.

Zur Auswahl stehen:

  • „Lokale Dateien“
  • „Internet Radio“
  • „Airplay“
  • „Medienserver(UPnP)“

Sie sollten hier eine Auswahl treffen, damit Sie diese Quellen verwenden können.

Je nach gewählter Option stehen Ihnen verschiedene Möglichkeiten zur Bedienung zur Verfügung. So können Sie bei „Internet Radio“, „Medienserver“ sowie bei den „Lokale Dateien“ durch die Liste an verfügbaren Medien/Sendern navigieren und Favoriten setzen. Im Falle von Airplay lässt sich der Name ändern, der bei einer Suche auf Ihrem Endgerät angezeigt wird.

In den Einstellungen jeder Quelle haben Sie außerdem die Möglichkeit einen oder mehrere Lautsprecher für die Ausgabe zuzuweisen sowie die aktuelle Ausgabe zu überprüfen und mittels entsprechender Buttons zu steuern.

Multiroom Mode:
Sollten Sie mehr als ein Soundmodul verbaut haben, steht Ihnen die Funktion Multiroom zur Verfügung. Im Master-Modus werden dann für jeden Lautsprecher die beiden Quellen des ersten Soundmoduls verwendet. Die Gesamtanzahl der verschiedenen Quellen reduziert sich somit auf 2, jedoch erfolgt die Musikausgabe vollständig synchron in den einzelnen Räumen.

Equalizer:
Zur erweiterten Anpassung der Musikqualität, steht Ihnen im Parameterpanel der anpassbaren Quellen noch ein Equalizer mit Voreinstellungen für diverse Musikrichtungen zur Verfügung.

Zum Streamen von Spotify Musik über Android-Geräte kann das App HiFy vom Google Play Store verwendet werden (https://play.google.com/store/apps/details?id=eu.hify.pro&hl=de_AT). Einfach die Quelle auf AirPlay umstellen und in der App als Empfänger (Receiver) auswählen.

FM-Radio

Der FM-Radio ermöglicht zusätzlich zu den 2 dynamisch verwendbaren Quellen die Musikausgabe auf den Lautsprechern. In der Fußzeile können beliebige UKW-Radiosender gespeichert werden. Die Vor/Zurück-Icons ermöglichen das manuelle Einstellen der Frequenz bzw. einen automatischen Sendersuchlauf. Das Anzeigefeld der aktuellen Frequenz kann auch zur direkten Frequenz-Vorgabe verwendet werden.
Für den optimalen Empfang wird die Verwendung einer externen Wurfantenne empfohlen.

Lautsprecher

Je nachdem, welche Einstellungen (Stereo und Mono Gruppen) Sie bei der Konfiguration Ihres Audiomoduls vorgenommen haben , werden Ihnen zwischen 1 und 4 Lautsprecher angezeigt.

Im ObjectPanel Ihres Lautsprechers werden die Informationen über die aktuelle Medienwiedergabe angezeigt. Darüber hinaus können Sie hier auch die Lautstärke verändern, wenn Sie die passende Panelgröße eingestellt haben.

Sie können jedem Lautsprecher eine von den verfügbaren 4 Quellen zuweisen. Wurde eine Quelle ausgewählt, sehen Sie im unterem Bereich der Anzeige was gerade gespielt wird und können die Lautstärke anpassen.

Bei der Verwendung von Airplay als Quelle kann die Lautstärke der Wiedergabe zusätzlich über das verbundene Gerät gesteuert werden.

Es empfiehlt sich daher die Lautstärke des Lautsprechers etwas höher zu stellen oder anzupassen.

In den Einstellungen des Lautsprechers können Sie wie gewohnt den Namen und den zugewiesenen Raum anpassen. Außerdem sehen Sie Informationen über den einzelnen Lautsprecher.

Darüber hinaus können Sie Ihrem Lautsprecher einen Taster zuweisen, über den die Wiedergabe gesteuert werden kann.

Die Geschwindigkeit, mit der die Lautstärke bei einem langen Tastendruck verändert wird, kann mit einem Schieberegler angepasst werden.

Möchten Sie, dass die Wiedergabe nach einer festgelegten Zeitspanne automatisch stoppt, können Sie den „Sleep Timer“ aktivieren und nach Ihren Wünschen anpassen.

Szenen

Die Musik App bietet folgende Funktionen für Szenen (dann ...):
- Internet Radio abspielen: Die Quelle wird mit dem Internet -Radio belegt
- Lokale Dateien - Favoriten abspielen: Ein beliebiger Favorit der lokalen Dateien wird auf der Quelle abgespielt
- Medienserver - Favoriten abspielen: Ein beliebiger Favorit vom Medienserver(NAS) wird auf der Quelle abgespielt
- Nächster Titel/Stream: Auf den nächsten Titel/Stream wird gewechselt
- Voriger Titel/Stream: Auf den vorherigen Titel/Stream wird gewechselt
- (UKW) Frequenz einstellen: Eine beliebige Frequenz kann für den UKW-Radio vorgegeben werden
- (UKW) Sender suchen: Der Sendersuchlauf für den UKW-Radio wird gestartet

my-PV

Die my-PV Geräte AC-ELWA und AC-THOR ermöglichen die Nutzung überschüssig erzeugter Energie (z. B. aus einem Photovoltaik-System) zur Warmwassererzeugung. In wenigen Schritten können die Geräte für den Betrieb mit dem Smart Building Automation System konfiguriert werden.

Die App ist unter „Alle Apps“ - „my-PV" zu finden

Erstellen

Für die Integration der my-PV Geräte sind einige Vorbereitungen erforderlich. Dazu wird die IP-Adresse des jeweiligen Geräts benötigt.

Das Gerät muss sich im Modus „Modbus TCP“ befinden. Informationen zur Aktivierung dieses Modus sind in der Anleitung des jeweiligen Geräts zu finden.

Zusätzlich sollte dem Gerät eine statische IP-Adresse zugewiesen werden. Diese muss zum verwendeten Netzwerk passen und darf nicht bereits von einem anderen Netzwerkgerät verwendet werden.

Nach der Inbetriebnahme kann das Gerät über „Gerät hinzufügen“ in das System integriert werden.

Durch Klick auf „Weiter“ werden die nächsten Schritte der Integration geladen. Es besteht jederzeit die Möglichkeit mittels „Abbrechen“ die Integration abzubrechen.

Im ersten Schritt muss das my-PV Gerät für die Integration in das Smart Building Automation System vorbereitet werden (siehe Punkt 1).

Im nächsten Schritt ist die Eingabe der Geräte IP-Adresse erforderlich.

Im Regelfall wird der Typ des Gerätes automatisch erkannt und der Schritt 3 übersprungen. Sollte dies jedoch nicht der Fall sein, muss der Typ manuell ausgewählt werden.

In Schritt 4 muss der Name und die Örtlichkeit vergeben werden. Dieser kann jederzeit verändert werden.

Als nächstes muss die Quelle der externen Leistungsvorgabe ausgewählt werden. Dies gibt die Soll-Heizleistung des my-PV Gerätes vor. Im abgebildeten Beispiel wird der vom des Smart Meter gemessene Leistungsüberschuss, der in das Stromnetz eingespeist wird, verwendet.

Abschließend kann die Leistungsvorgabe konfiguriert werden. Dies ist insbesondere dann interessant, wenn mehrere my-PV Geräte verwendet werden.

Im letzten Schritt wird bestätigt, dass das Gerät erfolgreich integriert wurde.

Ist die Konfiguration abgeschlossen, erscheint das neue Gerät in der Übersicht des Smart Building Automation Systems.

Im Object Panel des Gerätes wird die aktuell gemessene Temperatur sowie die aktuell verwendete Leistung angezeigt.

Ein rotes „X“ signalisiert ein Verbindungsverlust zum Gerät. In diesem Fall sollte die Netzwerkverbindung überprüft werden.

Konfiguration

ACHTUNG: Damit das my-PV Gerät bedient werden kann, muss zuerst das Interface des Geräts geöffnet werden. Dazu die IP-Adresse des Geräts im Browser eingeben und suchen. Falls man nicht direkt auf das Interface kommt, sondern eine Warnung erscheint, bitte folgendes auswählen: Die IP Adresse ist mir bekannt. Geben Sie anschließend bei Bedarf die IP-Adresse erneut im Browser ein und suchen Sie erneut.
Nachdem das Interface geöffnet ist, muss wie im Bild unterhalb die Checkbox angehakt werden:

Das Parameterpanel erlaubt Ihnen jederzeit die Konfiguration zu prüfen und zu adaptieren.

Hier kann die Leistungsvorgabe geändert werden oder deren Parameter eingestellt werden.

Bei my-PV Geräten ohne Drehknopf zur Einstellung der Abschalttemperatur kann diese im Parameter Panel eingestellt werden.

Bedienung

Am Operatorpanel werden Ihnen der aktuelle Status und die wichtigsten Informationen des Gerätes dargestellt.

Durch Aktivierung von „Manuelle Steuerung“ wird die externe Leistungsvorgabe gesperrt. Die Leistung kann dann mithilfe des erscheinenden Sliders festgelegt werden.

Ist im my-PV Gerät der Sicherstellungsmodus aktiviert, wird ein Button „Sicherstellung einmalig starten“ sichtbar. Durch Klick auf diesen Button wird die Sicherstellung am Gerät gestartet und bleibt bis zur Erreichung der Zieltemperatur aktiv.

Verwendung der Leistungsvorgabe:
Der Wert der externen Leistungsvorgabe wird aus technischen Gründen geglättet. Die Glättung erfolgt über ein gleitendes Durchschnittsverfahren, welches die Leistungsvorgabe über 120 Werte der letzten Minute berücksichtigt.

Die aktuell geglättete Leistungsvorgabe wird anschließend überprüft und begrenzt. Dabei muss dieser Wert größer als die eingestellte „Mindestleistung“ sein und wird auf die „Maximalleistung“ begrenzt. Der daraus resultierende Wert wird mit dem Faktor „Verwendeter Anteil“ multipliziert. Die errechnete Leistung wird anschließend dem my-PV Gerät zur Wärmegewinnung übergeben.

Szenen

my-PV bietet folgende Funktionen für Szenen (dann ...):

  • Ausschalten
  • Einschalten
  • Externe Vorgabe sperren
  • Leistung setzen

Verwendung im Energiemanagement

Wenn ein my-PV Gerät im Energiemanagement verwendet wird, wird diese Leistung vom Energiemanagement bestimmt und die manuelle Bedienung ignoriert.

Logik

my-PV bietet folgende Möglichkeiten für die Verwendung in Logiken:

  • Aktuelle Leistung: die aktuelle Leistung in kW (lesen)
  • Ein: trifft zu, wenn my-PV aktiv ist (lesen)
  • Eingestellte Temperatur: die Solltemperatur in °C (lesen)
  • Gesetzte Leistung: die aktuell an my-PV vorgegebene Leistung (lesen)
  • Temperatur in °C: die aktuelle Temperatur in °C (lesen)

Netatmo

The Netatmo App allows you to integrate your Netatmo Weatherstation and its Rain Gauge extension.

The Netatmo app is located under “all apps” – “Netatmo”.

Unterstütze Geräte

Folgende Geräte werden im Smart Building Automation System unterstützt:

  • Wetterstation, welche aus einem Innenmodul und einen Außenmodul besteht
  • Zusätzliches Innenmodul
  • Regenmesser
  • Windmesser

Create

In the "Netatmo" app, a weather station can be added by selecting "add Netatmo". The Netatmo credentials are then required to link the account to the system.

Confirm to proceed.

After a successful login, all Netatmo Weather Stations associated with the connected account are loaded and added to the system.

Operation

The OperatorPanel of your Netatmo Device will list its aggregated data like noice, temperature, pressure and more.

It will also display the last time those values were loaded from the device.

At the bottom of the panel, you will find a diagram displaying all records for a selected value over a chosen time. You can change the value or timeframe via the provided dropdowns.

Configuration

The parameter panel of each Netatmo device allows you to adjust its name and area as well as its displayed value, which will be shown in the object panel of the device. For example, the Netatmo base station lets you select one of the following values:

  • noise
  • temperature
  • humidity
  • pressure
  • CO2

Besides choosing a display value, you will also find a list of basic location information for the current Netatmo device, which are fetched from your Netatmo account.

Logik

Die Netatmo App bietet folgende Möglichkeiten für die Verwendung in Logiken:

  • Fehler: Ob das Gerät einen Fehler aufweist (lesen)
  • Luftdruck: Der aktuelle Luftdruck (lesen) (Innenmodule)
  • Sonometer: Die aktuelle Lautstärke (lesen) (Innenmodule)
  • CO2: Der aktuelle CO2-Wert (lesen) (Innenmodule und zusätzliche Innenmodule)
  • Luftfeuchtigkeit: Die aktuelle Luftfeuchtigkeit (lesen) (Innenmodule, zusätzliche Innenmodule und Außenmodule)
  • Temperatur: Die aktuelle Temperatur (lesen) (Innenmodule, zusätzliche Innenmodule und Außenmodule)
  • Höchsttemperatur: Die aktuelle Tageshöchsttemperatur (lesen) (Zusätzliche Innenmodule und Außenmodule)
  • Tiefsttemperatur: Die aktuelle Tagestiefsttemperatur (lesen) (Zusätzliche Innenmodule und Außenmodule)
  • Ladezustand: Der aktuelle Ladestand der Batterie (Zusätzliche Innenmodule, Außenmodule, Regenmesser, Windmesser)
  • Aktueller Wert: Die aktuelle Regenmenge (Regenmesser)
  • Heute: Die Regenmenge der letzten 24 Stunden (Regenmesser)
  • Letzte Stunde: Die Regenmenge der letzten Stunde (Regenmesser)
  • Letzten 3 Tage: Die Regenmenge der letzten 3 Tage (Regenmesser)
  • Letzten 7 Tage: Die Regenmenge der letzten 7 Tage (Regenmesser)

Nuki

Die „Nuki“ App ermöglicht die Integration von Nuki Smart Locks in das Smart Building Automation System.

Die „Nuki“ App ist unter „Alle Apps“ – „Einstellungen“ - „Nuki“ zu finden.

Vorbereitung

Bevor Nuki Smart Locks im Smart Building Automation System verwendet werden können, muss die Nuki Bridge mit Strom versorgt und die von Nuki bereitgestellte „Nuki“ App auf einem Smartphone installiert werden. Nach der Installation die App öffnen und folgende Schritte durchführen:

1.) „Gerät einrichten“ auswählen.
2.) „Smart Lock“ auswählen und den weiteren Schritten folgen.
3.) In der „Checkliste“ wird empfohlen, zunächst die Bridge einzurichten und das Smart Lock mit dieser zu koppeln.
4.) Soll auch der Türsensor verwendet werden, „Türsensor aktivieren“ auswählen und den weiteren Schritten folgen.
5.) Die restlichen Einstellungen können nach Bedarf vorgenommen werden.

Nachdem das Smart Lock hinzugefügt wurde, muss die Verbindung mit der Bridge hergestellt werden. Dazu unter „Meine Geräte verwalten - Bridge“ die entsprechende Bridge auswählen und eine Verbindung herstellen. Anschließend kann das Smart Lock über „+“ mit der Bridge verbunden werden. Nach erfolgreicher Verbindung unter „Bridge“ > „Entwickler“ die Optionen „API Schnellverbindung“ und „HTTP API“ aktivieren. Diese Einstellungen sind erforderlich, damit die Bridge mit dem Smart Building Automation System kommunizieren kann. Anschließend die vorgenommenen Einstellungen über den Haken speichern.

Um alle Funktionen des Smart Locks nutzen zu können, unter „Meine Geräte verwalten - Smart Lock“ das entsprechende Smart Lock auswählen und „Administration“ öffnen. Unter „Lock 'n' Go Dauer“ kann festgelegt werden, nach welcher Zeit das Smart Lock verriegelt wird, wenn die Szenen-Funktion „LockAndGo aktivieren“ ausgelöst wird.

Abschließend sicherstellen, dass sich die Bridge im selben Netzwerk wie das Smart Building Automation System befindet. Anschließend kann mit den folgenden Schritten fortgefahren werden.

Einbindung

Navigieren Sie zu „Alle Apps“ - „Einstellungen“ - „Nuki“.

Jede Nuki Bridge, die mit dem System verbunden ist, wird hier gelistet. Durch Klick auf das „Bridge hinzufügen“ Panel, kann eine neue Bridge hinzugefügt werden.

Darauf hin öffnet sich ein Popup und alle, im Netzwerk gefundenen Bridges werden angezeigt.

Achtung: Es können maximal 3 Nuki Bridges in das Smart Building Automation System!

Nach der Auswahl einer Bridge muss innerhalb von 30 Sekunden der Link Button auf der Bridge gedrückt werden, um die Verbindung zu bestätigen. Nach erfolgreicher Verbindung wird eine Bestätigung sowie die Anzahl der hinzugefügten Smart Locks angezeigt. Anschließend kann das Popup geschlossen werden.

Die Nuki Bridge ist nun mit dem Smart Building Automation System verbunden.

Alle Nuki Smart Locks, die mit der Bridge verknüpft und bereits erkannt wurden, werden dem System hinzugefügt. Wird die Nuki Konfiguration später geändert oder wurde ein Smart Lock noch nicht erkannt, kann im Operator Panel der Bridge über „Nach neuen Geräten suchen“ erneut nach Geräten gesucht werden.

Über den Button „Geräte anzeigen“ können alle aktuell verbundenen Smart Locks angezeigt werden.

Alle verbundenen Smart Locks werden auch in der Zutrittssystem App angezeigt, welche unter „Alle Apps“ - „Zutrittssystem“ gefunden werden können.

Nuki Web

Wird im Menü die Option „Nuki Web“ ausgewählt, erfolgt die Weiterleitung zum Nuki Web-Portal. Dort ist die Anmeldung mit dem Nuki-Konto erforderlich.

Nach erfolgreicher Anmeldung wird das Nuki Web-Konto automatisch verknüpft, sodass der Status und die Einstellungen in der App verwaltet werden können.

Konfiguration

Nach dem Hinzufügen der Nuki Bridge und der Smart Locks, wie im Abschnitt „Einbindung“ beschrieben, oder nach dem Herstellen einer Verbindung mit Nuki Web ist keine weitere Konfiguration erforderlich.

Werden zu einem späteren Zeitpunkt weitere Nuki Smart Locks hinzugefügt oder entfernt, kann in den Einstellungen der Bridge oder Nuki Web im Operator Panel die Schaltfläche „Nach neuen Geräten suchen“ verwendet werden. Dabei wird nach verfügbaren Smart Locks gesucht. Neu erkannte Geräte werden anschließend dem System hinzugefügt.

Zudem werden im Operator Panel der Bridge folgende Informationen angezeigt:

  • Ob die Bridge verbunden ist
  • Den Zeitpunkt des letzten Datenerhalts
  • Ob die Smart Locks ihren Status automatisch aktualisieren
  • Die IDs des verbundenen Servers und Bridge
  • Die Firmware Version der Bridge

Bedienung

Alle verbundenen Smart Locks werden zur Zutrittssystem App hinzugefügt, die unter „Alle Apps“ - „Zutrittssystem“ zu finden ist.

Im Operator Panel des Smart Locks wird der aktuelle Status sowohl symbolisch als auch in Textform angezeigt. Darunter stehen Funktionen zum Auf- und Zusperren des Smart Locks zur Verfügung.

Ist ein Türsensor eingerichtet, wird auch dessen Status angezeigt.

ACHTUNG: Der Status des Türsensors wird nur von Smart Locks der Serie 2.0 angezeigt.

Unter dem Reiter „Ladezustand“ wird außerdem die verbleibende Akkuleistung des Smart Locks angezeigt.

Im Parameter Panel ist neben der Bezeichnung und dem Bereich auch der Reiter „Status“ vorhanden.
Unter diesem werden folgende Informationen angezeigt:

  • Ob das Gerät verbunden ist
  • Den Zeitpunkt des letzten Datenerhalts
  • Die ID des Nuki Geräts
  • Die Firmware Version des Geräts
    Zudem kann unter dem Reiter „Einstellungen“ das Smart Lock permanent auf- oder zugesperrt werden.

Szenen

Die Nuki App bietet folgende Auslöser für Szenen (wenn ...):

  • Batterie bald leer: Die Batterie des Smart Locks ist bald leer
  • Smart Lock aufgesperrt: Das Smart Lock wurde aufgesperrt
  • Smart Lock zugesperrt: Das Smart Lock wurde zugesperrt
  • Tür geöffnet: Die Tür wurde geöffnet (wird nur bei konfiguriertem Türsensor ausgelöst)
  • Tür geschlossen: Die Tür wurde geschlossen (wird nur bei konfiguriertem Türsensor ausgelöst)

Die Nuki App bietet folgende Funktionen für Szenen (dann ...):

  • Smart Lock aufsperren: sperrt das Smart Lock auf
  • Smart Lock zusperren: sperrt das Smart Lock zu
  • Tür öffnen: öffnet die Tür
  • LockAndGo: sperrt das Smart Lock nach einer vordefinierten Zeit (Standard: 30 Sekunden) zu (Dieser Wert über die Nuki App des Herstellers geändert werden)
  • Tür öffnen und LockAndGo aktivieren: öffnet die Tür und nach einer vordefinierten Zeit (Standard: 30 Sekunden) sperrt das Smart Lock zu

Logik

Die Nuki App bietet folgende Möglichkeiten für die Verwendung in Logiken:

  • Smart Lock permanent aufsperren: Tür wird permanent aufgesperrt (schreiben)
  • Smart Lock permanent zusperren: Tür wird permanent zugesperrt (schreiben)
  • Batterie bald leer: Batterie ist bald leer (lesen)
  • Ladezustand der Batterie Verbleibender Akku des Smart Locks (lesen)
  • Smart Lock zugesperrt: Ob das Smart Lock zugesperrt ist (lesen)

Philips Hue

The Philips Hue App makes it possible to integrate Philips Hue lights into the Smart Building Automation system.

"Philips Hue" is located under "all apps" – "settings" - "Philips Hue".

Creation

Before Philips Hue lights can be used in the Smart Building Automation system, the Philips Hue Bridge must first be connected. Make sure the Bridge is on the same network as the system, then follow these steps.

Navigate to "All Apps" - "Settings" - "Philips Hue".

All Philips Hue Bridges connected to the system are listed here. To add a new Bridge, use the "Add new bridge" panel.

The system now searches for all available Philips Hue Bridges within the local network and displays them in a popup.

Select the Philips Hue Bridge to be connected to the system. Then press the link button on the Philips Hue Bridge to confirm the connection.

Once the connection has been established, a confirmation message is displayed. The popup can then be closed.

The Philips Hue Bridge is now connected to the Smart Building Automation system.

All Philips Hue devices linked to the Bridge are added to the system. If the Philips Hue configuration is changed later, for example by adding or removing devices, use the "Search for new devices" button in the Operator Panel to search for devices again.

Use the "Show devices" button to display all currently connected Philips Hue devices.

All connected Philips Hue lights are also displayed in the "Lights" app, while all Philips Hue sockets are displayed in the "Sockets" app. The apps can be found under "All Apps" - "Lights" and "All Apps" - "Sockets", respectively.

Configuration

Besides adding the Philips Hue Bridge and its connected lights to the Smart Building Automation system as described in the "Create" section, no further configuration is required. If Philips Hue lights are added or removed later, use the "Search for new lights" button in the Bridge's Operator Panel to search for lights again. Newly detected lights are then added to the system.

Operation

All connected Philips Hue Lights are added to the Lights App, which can be found under "All apps" - "Lights". They behave like RGBW lights and provide the same basic controls and functionality like changing color, adjusting brightness or creating scenes with the Scenes app.

The OperatorPanel of each Philips Hue light provides you with a color wheel for selecting the desired color and a slider for adjusting the brightness. You can also add the current color/brightness combination to your favorites and activate them on demand.

Pool

Die Pool-App bietet die Möglichkeit, eine Poolsteuerung durch Auswahl von Ventilen, Pumpen und anderen verknüpfbaren Geräten zu erstellen.

Die Pool-App kann unter Alle AppsPools gefunden werden.

Achtung: Die Pool App wurde in Kooperation mit Peraqua® entwickelt, weshalb eine ordnungsgemäße Funktion ausschließlich mit den Produkten von Peraqua® gewährleistet wird, insbesondere:
6-Wegeventil AquaStar mp6
Schwimmbadpumpe E.Pro 150
Salzelektrolyseanlage iQntrol SALT-MOBUS
Dosieranlage iQntrol DOS-MODBUS
Wärmepumpe Smart iQ INVER Silence Full Inverter

Erstellen

Durch Klick auf Hinzufügen kann der Wizard gestartet werden.

Durch Klick auf Start gelangt man zur Übersicht, in der Pools sowie einzelne Geräte erstellt werden können.

Durch Klick auf eines der Elemente wird dieses entweder sofort erstellt oder der Wizard des jeweiligen Geräts gestartet. Wird ein Wizard gestartet, sind die weiteren Schritte aus dem jeweiligen Kapitel Erstellen des Geräts oder des Pools zu entnehmen.

Pool

Erstellen

Als Vorbereitung für das Erstellen des Pools muss über den Wizard der Pool ausgewählt worden sein.

Start des Pool-Wizards nachdem Pool im Pool-Wizard ausgewählt wurde.

Im ersten Schritt kann ein 6-Wege-Ventil verknüpft werden. Sollte sich noch kein 6-Wege-Ventil im System befinden, kann dieses durch Klick auf Hinzufügen erstellt werden.

Im zweiten Schritt kann eine Pumpe verknüpft werden. Sollte sich noch keine Pumpe im System befinden, kann diese durch Klick auf Hinzufügen erstellt werden.

Im dritten Schritt kann ein Temperatursensor verknüpft werden.

Im vierten Schritt kann ein Gerät für die Wasseraufbereitung verknüpft werden. Sollte sich noch kein Gerät für die Wasseraufbereitung im System befinden, gibt es die Möglichkeit eine Dosieranlage oder eine Salzelektrolyseanlage zu erstellen. Durch Klick auf eines der beiden Elemente, wird der Wizard des jeweiligen Geräts gestartet.

Im fünften Schritt kann ein Abflussventil verknüpft werden. Sollte sich noch kein Abflussventil im System befinden, kann dieses durch Klick auf Hinzufügen erstellt werden.

Im sechsten Schritt kann eine Füllstandskontrolle verknüpft werden.

Im letzten Schritt kann eine Wärmepumpe verknüpft werden. Sollte sich noch keine Wärmepumpe im System befinden, kann durch Klick auf Hinzufügen der Wizard zum Erstellen der Wärmepumpe gestartet werden.

Der Pool wurde erfolgreich erstellt.

Konfiguration

Im Parameter Panel können Geräte für die Poolsteuerung verlinkt, und die Betriebszeiten für den automatischen Modus eingestellt werden.

Bei den Betriebszeiten können für das Programm Filtern Zeitspannen, und für das Programm Rückspülen Startzeitpunkte festgelegt werden.

Beim Programm Rückspülen wird zuerst rück- und danach klargespült. Für beide Abschnitte des Programms kann eine Dauer gewählt werden.

Funktionsweise

Mit der Pool-App ist es möglich Funktionen verknüpfter Komponenten in richtiger Reihenfolge aufzurufen.

Am Beispiel des Programms Filtern sieht die Haupt-Abarbeitungsreihenfolge wie folgt aus:

  1. Befindet sich das Ventil nicht in der Position Filtern, wird die Pumpe ausgeschaltet
  2. Befindet sich das Ventil nicht in der Position Filtern, wird es in die richtige Position gebracht
  3. Pumpe wartet auf das Signal des Ventils und wird danach eingeschaltet
  4. Nach abgelaufener Zeit des Programms Filtern wird die Pumpe wieder ausgeschaltet

Am Beispiel des Programms Rückspülen sieht die Haupt-Abarbeitungsreihenfolge wie folgt aus:

  1. Befindet sich das Ventil nicht in der Position Rückspülen, wird die Pumpe ausgeschaltet
  2. Befindet sich das Ventil nicht in der Position Rückspülen, wird es in die richtige Position gebracht
  3. Pumpe wartet auf das Signal des Ventils und wird danach eingeschaltet
  4. Nach abgelaufener Zeit des Programms Rücksplüen wird die Pumpe wieder ausgeschaltet
  5. Ventil verstellt auf die Position Klarspülen
  6. Pumpe wartet auf das Signal des Ventils und wird danach eingeschaltet
  7. Nach abgelaufener Zeit des Programms Klarsplüen wird die Pumpe wieder ausgeschaltet
  8. Das Ventil wird in die Standardposition Filtern gebracht

Wenn zusätzliche Geräte wie ein Abflussventil oder eine Wasseraufbereitung verknüpft sind, werden entsprechende Aktionen gemäß des jeweiligen Geräts an der richtigen Stelle in der Abarbeitungsreihenfolge beider Programme eingefügt.

Bedienung

Im Operator Panel gibt es die Möglichkeit, zwischen einer automatischen und manuellen Steuerung zu wählen. Der automatische Modus ist nur dann auswählbar, wenn alle notwendigen Geräte für die beiden Programme Filtern und Rückspülen verknüpft und auch vollständig konfiguriert sind.

Für das Programm Filtern müssen folgende Geräte verknüpft und konfiguriert sein: 6-Wege-Ventil und Pumpe.
Für das Programm Rückspülen müssen folgende Geräte verknüpft und konfiguriert sein: 6-Wege-Ventil und Pumpe.

Weiters wird das aktuelle Programm angezeigt.
Läuft gerade ein Programm, wird die Restzeit angezeigt.
Ist der Modus auf Automatisch, in den Betriebszeiten eine Zeitspanne für Filtern oder ein Zeitpunkt für Rückspülen gesetzt und kein Programm aktiv, wird der nächste Startzeitpunkt angezeigt.

Die verknüpften Geräte werden weiter unten im Operator Panel dargestellt und können durch einen Klick auf das jeweilige Gerät ausgewählt und bearbeitet werden.

Darstellung

Darstellung des Pools durch das Object Panel.

Durch Klicken und Halten auf den Pool kann die Ansicht durch Klick auf Größe ändern erweitert bzw. verringert werden.

Bei der ersten erweiterten Darstellung, die auf mobilen Endgeräten und auf Desktopgeräten verfügbar ist, wird zusätzlich ein Status angezeigt. Ist das Gerät nicht vollständig konfiguriert, wird eine Warnung und, falls nicht verknüpft, ein Hinweis angezeigt. Diese Ansicht ist bei mobilen Endgeräten standardmäßig aktiviert.

Wenn es sich um ein Desktop-Endgerät handelt, kann die Ansicht ein weiteres Mal vergrößert werden. Diese Ansicht ist bei Desktop-Endgeräten standardmäßig aktiviert.

Szenen

Die Pool-App bietet folgende Funktionen für Szenen (dann ...):

  • Filtern: Filtern wird gestartet
  • Rückspülen: Rückspülen wird gestartet

6-Wege-Ventil

Verdrahtung

Eingänge

Spannungsbereich
Eingänge: 8-24VDC
Versorgung: 12-24VDC

Versorgung der Eingänge auch über Jumper ST13 und ST16 möglich. GND und +24VDC müssen jedoch auf jeden Fall verbunden werden.

Ausgänge

Position 13/14: ganz wichtig, hier wird ein „bewegendes Ventil“ signalisiert d.h. Pumpe darf nicht laufen
Error 23/24: Fehler wird ausgegeben

Konfiguration

Modus Ausgänge: Für die Stellungen Filtern, Rückspülen und Klarspülen muss ein digitaler Ausgang verknüpft werden.

Fehler: Ein digitaler Ausgang kann verknüpft werden.
Status: Ein digitaler Ausgang muss verknüft werden.

Bedienung

Im Parameter Panel kann durch Klick auf Übernehmen der im Dropdown ausgewählte Modus übernommen werden.

Systemmeldungen

Gerät nicht vollständig konfiguriert

Diese Warnung sagt aus, dass die digitalen Ausgänge für Filtern, Rückspülen, Klarspülen und Status nicht verknüpft sind.

Dieser Fehler wird sofort erkannt, sobald das Gerät nicht vollständig konfiguriert ist.

In diesem Zustand kann kein Programm über den Pool gestartet werden.

Im Object Panel wird als Status ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird als Status ein gelbes Rufzeichen mit Warnhinweis angezeigt und die Bedienung ist deaktiviert.

Stromausfall

Dieser Fehler sagt aus, dass es zu einem Stromausfall gekommen ist.

Dieser Fehler wird sofort erkannt, sobald die Verbindung nicht mehr besteht.

In diesem Zustand kann das 6-Wege-Ventil nicht mehr bedient, und über den Pool kein Programm mehr gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Positionsfehler

Dieser Fehler sagt aus, dass das 6-Wege-Ventil auf einer nicht definierten Position steht.

Dieser Fehler wird sofort erkannt, sobald das 6-Wege-Ventil auf einer nicht definierten Position steht.

In diesem Zustand kann das 6-Wege-Ventil nicht mehr bedient, und über den Pool kein Programm mehr gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Stromfehler

Dieser Fehler sagt aus, dass es zu einem Stromfehler gekommen ist.

Dieser Fehler wird sofort erkannt, sobald es zu einem Stromfehler gekommen ist.

In diesem Zustand kann das 6-Wege-Ventil nicht mehr bedient, und über den Pool kein Programm mehr gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Stromfehlerzustand

Dieser Fehler sagt aus, dass sich das 6-Wege-Ventil nach einem Stromfehler im Stromfehlerzustand befindet.

Dieser Fehler wird sofort erkannt, sobald sich das 6-Wege-Ventil im Stromfehlerzustand befindet.

In diesem Zustand kann das 6-Wege-Ventil nicht mehr bedient, und über den Pool kein Programm mehr gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Einzelner Hall-Zustand

Dieser Fehler sagt aus, dass sich das 6-Wege-Ventil im Hall-Zustand befindet.

Dieser Fehler wird sofort erkannt, sobald sich das 6-Wege-Ventil im Hall-Zustand befindet.

In diesem Zustand kann das 6-Wege-Ventil nicht mehr bedient, und über den Pool kein Programm mehr gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Hall-Fehlerzustand

Dieser Fehler sagt aus, dass sich das 6-Wege-Ventil im Hall-Fehlerzustand befindet.

Dieser Fehler wird sofort erkannt, sobald sich das 6-Wege-Ventil im Hall-Fehlerzustand befindet.

In diesem Zustand kann das 6-Wege-Ventil nicht mehr bedient, und über den Pool kein Programm mehr gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Unbekannter Fehler

Dieser Fehler sagt aus, dass beim 6-Wege-Ventil ein unbekannter Fehler aufgetreten ist.

Dieser Fehler wird sofort erkannt, sobald beim 6-Wege-Ventil ein unbekannter Fehler aufgetreten ist.

In diesem Zustand kann das 6-Wege-Ventil nicht mehr bedient, und über den Pool kein Programm mehr gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Pumpe

Verdrahtung

Eingänge

1: Freigabe Start/Stopp
2: Analogsignal 0-10V steuert Volumenstrom, wobei 0V immer das regelbare Minimum von 6m³/h darstellt, 10V das Leistungsmaximum, in m³/h. Muss vor Ort gemessen werden

Ausgänge

Konfiguration

Start / Stopp: Es muss ein digitaler Ausgang ausgewählt werden.

Volumenstrom: Es muss ein analoger Ausgang ausgewählt werden.
Fehler: Es kann ein digitaler Eingang ausgewählt werden.
Status: Es muss ein digitaler Eingang ausgewählt werden.

Bedienung

Über die Buttons Start und Stopp kann die Pumpe ein- und ausgeschaltet werden.

Systemmeldung

Gerät nicht vollständig konfiguriert

Diese Warnung sagt aus, dass der digitale Ausgang für Start / Stopp und der analoge Ausgang für Volumenstrom nicht verknüpft ist.

Dieser Fehler wird sofort erkannt, sobald das Gerät nicht vollständig konfiguriert ist.

In diesem Zustand kann das Gerät nicht bedient, und über den Pool kein Programm gestartet werden.

Im Object Panel wird als Status ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird als Status ein gelbes Rufzeichen mit Warnhinweis angezeigt und die Bedienung ist deaktiviert.

Dosieranlage

Erstellen

Als Vorbereitung für das Erstellen der Dosieranlage muss die IP-Adresse des Geräts bekannt sein und über den Wizard die Dosieranlage ausgewählt worden sein.

Start des Dosieranlagen-Wizards nachdem Dosieranlage im Pool-Wizard ausgewählt wurde.

Im nächsten Schritt des Wizards wird man dazu aufegfordert, die IP-Adresse einzugeben. Mit Klick auf Weiter wird das Gerät gesucht. War die Suche erfolgreich wird das Gerät erstellt.

War die Suche nicht erfolgreich kann der Suchvorgang durch Klick auf Erneut versuchen wiederholt werden. Sollte das Gerät nach mehreren Versuchen nicht gefunden werden, kann das Gerät vorerst auch ohne gültige IP-Adresse erstellt werden.

Die Dosieranlage wurde erfolgreich hinzugefügt.

Konfiguration

Im Parameter Panel können Sollwerte für den ph-Wert und ORP-Wert eingestellt werden. Sollte sich die IP-Adresse des Geräts ändern, kann die Einstellung hier verändert werden.

Systemmeldungen

Verbindungsfehler

Dieser Fehler sagt aus, dass die Verbindung zur Dosieranlage unterbrochen ist.

Dieser Fehler wird sofort erkannt, sobald die Verbindung nicht mehr besteht.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Desinfektion leer

Dieser Fehler sagt aus, dass nicht mehr genügend Desinfektionsmittel vorhanden ist.

Dieser Fehler wird sofort erkannt, sobald nicht mehr genügend Desinfektionsmittel vorhanden ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

ph-Regelung leer

Dieser Fehler sagt aus, dass nicht mehr genügend Mittel zu ph-Regelung vorhanden ist.

Dieser Fehler wird sofort erkannt, sobald nicht mehr genügend Mittel zur ph-Regelung vorhanden ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Durchfluss des Probenwassers fehlt

Dieser Fehler sagt aus, dass der Durchfluss des Probenwassers fehlt.

Dieser Fehler wird sofort erkannt, sobald der Durchfluss des Probenwassers fehlt.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

ph-Regulierungsleck

Dieser Fehler sagt aus, dass es an der Dosieranlage ein ph-Regulierungsleck gibt.

Dieser Fehler wird sofort erkannt, sobald es an der Dosieranlage ein ph-Regulierungsleck gibt.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Desinfektionsleck

Dieser Fehler sagt aus, dass es an der Dosieranlage ein Desinfektionsleck gibt.

Dieser Fehler wird sofort erkannt, sobald es an der Dosieranlage ein Desinfektionsleck gibt.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Flockung leer

Dieser Fehler sagt aus, dass die Flockung der Dosieranlage leer ist.

Dieser Fehler wird sofort erkannt, sobald die Flockung der Dosieranlage leer ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Flockungsleck

Dieser Fehler sagt aus, dass es an der Dosieranlage ein Flockungsleck gibt.

Dieser Fehler wird sofort erkannt, sobald es an der Dosieranlage ein Flockungsleck gibt.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Minimaler ph-Wert unterschritten

Dieser Fehler sagt aus, dass der minimale ph-Wert an der Dosieranlage unterschritten wurde.

Dieser Fehler wird sofort erkannt, sobald der minimale ph-Wert an der Dosieranlage unterschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Maximaler ph-Wert überschritten

Dieser Fehler sagt aus, dass der maximale ph-Wert an der Dosieranlage überschritten wurde.

Dieser Fehler wird sofort erkannt, sobald der maximale ph-Wert an der Dosieranlage überschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Minimaler Cl2-Wert unterschritten

Dieser Fehler sagt aus, dass der minimale Cl2-Wert unterschritten wurde.

Dieser Fehler wird sofort erkannt, sobald der minimale Cl2-Wert unterschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Maximaler Cl2-Wert überschritten

Dieser Fehler sagt aus, dass der maximale Cl2-Wert überschritten wurde.

Dieser Fehler wird sofort erkannt, sobald der maximale Cl2-Wert überschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Minimaler mV-Wert unterschritten

Dieser Fehler sagt aus, dass der minimale mV-Wert unterschritten wurde.

Dieser Fehler wird sofort erkannt, sobald der minimale mV-Wert unterschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Maximaler mV-Wert überschritten

Dieser Fehler sagt aus, dass der maximale mV-Wert überschritten wurde.

Dieser Fehler wird sofort erkannt, sobald der maximale mV-Wert überschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Minimaler Temperaturwert unterschritten

Dieser Fehler sagt aus, dass der minimale Temperaturwert unterschritten wurde.

Dieser Fehler wird sofort erkannt, sobald der minimale Temperaturwert unterschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Maximaler Temperaturwert überschritten

Dieser Fehler sagt aus, dass der maximale Temperaturwert überschritten wurde.

Dieser Fehler wird sofort erkannt, sobald der maximale Temperaturwert überschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Dynamische Dosierzeitüberwachung pH überschritten

Dieser Fehler sagt aus, dass die dynamische Dosierzeitüberwachung des pH-Werts überschritten wurde.

Dieser Fehler wird sofort erkannt, sobald die dynamische Dosierzeitüberwachung des pH-Werts überschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Dynamische Dosierzeitüberwachung Cl2 überschritten

Dieser Fehler sagt aus, dass die dynamische Dosierzeitüberwachung des Cl2-Werts überschritten wurde.

Dieser Fehler wird sofort erkannt, sobald die dynamische Dosierzeitüberwachung des Cl2-Werts überschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Dynamische Dosierzeitüberwachung mV überschritten

Dieser Fehler sagt aus, dass die dynamische Dosierzeitüberwachung des mV-Werts überschritten wurde.

Dieser Fehler wird sofort erkannt, sobald die dynamische Dosierzeitüberwachung des mV-Werts überschritten wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Pufferspeicher deaktiviert

Dieser Fehler sagt aus, dass der Pufferspeicher deaktiviert wurde.

Dieser Fehler wird sofort erkannt, sobald der Pufferspeicher deaktiviert wurde.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Sammelstörung

Dieser Fehler sagt aus, dass eine Sammelstörung auftrat.

Dieser Fehler wird sofort erkannt, sobald eine eine Sammelstörung auftrat.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Salzelektrolyseanlage

Erstellen

Als Vorbereitung für das Erstellen der Salzelektrolyseanlage muss das Gerät an den Controller oder an ein TA-Modul angeschlossen und über den Wizard die Salzelektrolyseanlage ausgewählt worden sein.

Start des Salzelektrolyseanlagen-Wizards nachdem Salzelektrolyseanlage im Pool-Wizard ausgewählt wurde. In diesem Schritt ist die Schnittstelle, an die die Salzelektrolyseanlage angeschlossen ist, auszuwählen.

Nach der Auswahl der Schnittstelle werden die Einstellungen übernommen.

Im nächsten Schritt muss die Adresse ausgewählt werden.

Abschließend wird eine Zusammenfassung angezeigt.

Die Salzelektrolyseanlage wurde erfolgreich hinzugefügt.

Konfiguration

Im Parameter Panel können Sollwerte für ph-Wert, ORP-Wert, Reinigungszyklus sowie Produktionssollwert eingestellt werden. Sollte sich die Slave-ID des Geräts ändern, kann die Einstellung hier verändert werden.

Systemmeldungen

Verbindungsfehler

Dieser Fehler sagt aus, dass die Verbindung zur Salzelektrolyseanlage unterbrochen ist.

Dieser Fehler wird sofort erkannt, sobald die Verbindung nicht mehr besteht.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

ORP-Sonde gesättigt

Dieser Fehler sagt aus, dass die ORP-Sonde der Salzelektrolyseanlage gesättigt ist.

Dieser Fehler wird sofort erkannt, sobald die ORP-Sonde der Salzelektrolyseanlage gesättigt ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Übertemperatur Chlorgasdosiergerät

Dieser Fehler sagt aus, dass die Temperatur des Chlorgasdosiergeräts zu hoch ist.

Dieser Fehler wird sofort erkannt, sobald die Temperatur des Chlorgasdosiergeräts zu hoch ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Offener Kreislauf

Dieser Fehler sagt aus, dass der Kreislauf nicht mehr geschlossen ist.

Dieser Fehler wird sofort erkannt, sobald der Kreislauf nicht mehr geschlossen ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Kein Wasserdurchfluss

Dieser Fehler sagt aus, dass kein Wasserdurchfluss mehr vorhanden ist.

Dieser Fehler wird sofort erkannt, sobald kein Wasserdurchfluss mehr vorhanden ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Kurzschluss

Dieser Fehler sagt aus, dass es zu einem Kurzschluss gekommen ist.

Dieser Fehler wird sofort erkannt, sobald es zu einem Kurzschluss gekommen ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

pH-Alarm

Dieser Fehler sagt aus, dass es zu einer zu hohen Abweichung des pH-Werts gekommen ist.

Dieser Fehler wird sofort erkannt, sobald es zu einer zu hohen Abweichung des pH-Werts gekommen ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

PPM-Sonde

Dieser Fehler sagt aus, dass die PPM-Sonde nicht angeschlossen ist.

Dieser Fehler wird sofort erkannt, sobald die PPM-Sonde nicht angeschlossen ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Zu wenig Salz

Diese Warnung sagt aus, dass zu wenig Salz vorhanden ist.

Dieser Fehler wird sofort erkannt, sobald zu wenig Salz vorhanden ist

Im Object Panel wird als Status ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird als Status ein gelbes Rufzeichen mit Warnhinweis angezeigt.

Zu viel Salz

Diese Warnung sagt aus, dass zu viel Salz vorhanden ist.

Dieser Fehler wird sofort erkannt, sobald zu viel Salz vorhanden ist

Im Object Panel wird als Status ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird als Status ein gelbes Rufzeichen mit Warnhinweis angezeigt.

Zelle defekt

Diese Warnung sagt aus, dass die Zelle defekt ist.

Dieser Fehler wird sofort erkannt, sobald die Zelle defekt ist.

Im Object Panel wird als Status ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird als Status ein gelbes Rufzeichen mit Warnhinweis angezeigt.

ORP-Sonde nicht angeschlossen

Diese Warnung sagt aus, dass die ORP-Sonde nicht angeschlossen ist.

Dieser Fehler wird sofort erkannt, sobald die ORP-Sonde nicht mehr angeschlossen ist.

Im Object Panel wird als Status ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird als Status ein gelbes Rufzeichen mit Warnhinweis angezeigt.

Abflussventil

Konfiguration

Im Parameter Panel kann ein digitaler Ausgang für das Öffnen und Schließen des Abflussventils verknüpft und bei Bedarf auch invertiert werden.

Wenn die Option Einzelnen digitalen Ausgang verwenden deaktiviert ist, können separate digitale Ausgänge für das Öffnen und Schließen des Abflussventils ausgewählt werden.

Bedienung

Im Operator Panel lässt sich das Abflussventil öffnen und schließen.

Systemmeldungen

Gerät nicht vollständig konfiguriert

Diese Warnung sagt aus, dass die digitalen Ausgänge nicht verknüpft sind.

Dieser Fehler wird sofort erkannt, sobald das Gerät nicht vollständig konfiguriert ist.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird als Status ein gelbes Rufzeichen mit Warnhinweis angezeigt und die Bedienung ist deaktiviert.

Gleicher Status der digitalen Ausgänge. Soll das Ventil geöffnet oder geschlossen sein?

Diese Warnung sagt aus, dass die beiden digitalen Ausgänge denselben Status haben.

Dieser Fehler wird sofort erkannt, sobald die beiden digitalen Ausgänge denselben Status haben.

In diesem Zustand kann über den Pool das Programm Rückspülen nicht gestartet werden.

Im Object Panel wird als Status ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird als Status ein gelbes Rufzeichen mit Warnhinweis angezeigt und die Bedienung ist deaktiviert.

Peraqua Wärmepumpe

Erstellen

Als Vorbereitung für das Erstellen der Wärempumpe muss das Gerät an den Controller oder an ein TA-Modul angeschlossen und über den Wizard die Wärempumpe ausgewählt worden sein.

Start des Wärmepumpen-Wizards nachdem Wärempumpe im Pool-Wizard ausgewählt wurde. In diesem Schritt ist die Schnittstelle, an die die Wärempumpe angeschlossen ist, auszuwählen.

Nach der Auswahl der Schnittstelle werden die Einstellungen übernommen.

Im nächsten Schritt muss die Adresse ausgewählt werden.

Abschließend wird eine Zusammenfassung angezeigt.

Die Wärmepumpe wurde erfolgreich hinzugefügt.

Konfiguration

Im Parameter Panel kann das Raumklima durch Aktivieren der jeweiligen Checkbox sowohl gesetzt als auch übernommen werden.

Wird der Modus der Wärmepumpe geändert und Betriebsmodus für Raumklima übernhemen ist aktiviert, übernimmt das Raumklima den neu eingestellten Modus der Wärmepumpe.
Wird unter Einstellungen - Raumklima das Raumklima geändert und Betriebsmodus aus Raumklima übernehmen ist aktiviert, übernimmt die Wärempumpe den neu eingestellten Modus des Raumklimas.

Für die drei Betriebsmodi kann eine Solltemperatur gewählt werden. Dabei kann ein Fixwert bestimmt oder ein im System vorhandener Nummernwert verknüpft werden.

Bedienung

Im Operator Panel lässt sich die Wärmepumpe ein- bzw. ausschalten sowie der Betriebsmodus und die Betriebsstufe ändern.

Systemmeldungen

Verbindungsfehler

Dieser Fehler sagt aus, dass die Verbindung zur Wärmepumpe unterbrochen ist.

Dieser Fehler wird sofort erkannt, sobald die Verbindung nicht mehr besteht.

In diesem Zustand kann die Wärempumpe nicht mehr bedient werden.

Im Object Panel wird als Status ein rotes X angezeigt.
Im Operator Panel wird als Status ein rotes X mit Fehlertext angezeigt.

Projektor

„Mit der App „Projektor“ können Projektoren in das Smart Building Automation System eingebunden werden. Die App ist unter 'Alle Apps' - 'Projektor' zu finden.“

Es können nur Projektoren eingebunden werden, die dem PJLink-Standard entsprechen. Vor der Einbindung sollte geprüft werden, ob der verwendete Projektor diesen Standard unterstützt.

Konfiguration des Projektors

Bevor der gewünschte Projektor in das Smart Building Automation System integriert werden kann, müssen die Standby-Einstellungen des Projektors so konfiguriert werden, dass die Netzwerkverbindung auch im Standby-Modus aktiv bleibt. Informationen dazu sind in der Bedienungsanleitung des Projektors zu finden.

Erstellen

Um einen Projektor in das Smart Building Automation System einzubinden, die App „Projektor“ öffnen und das Panel „Projektor hinzufügen“ auswählen.

Anschließend öffnet sich ein Fenster, in dem die IP-Adresse des gewünschten Projektors eingegeben werden kann. Mit einem Klick auf „Projektor suchen“ wird versucht, eine Verbindung zum Projektor herzustellen.

Kann keine Verbindung hergestellt werden, sollten die IP-Adresse sowie die Netzwerkverbindung des Projektors überprüft werden.

Nach erfolgreicher Verbindung wird das Fenster geschlossen und der Projektor dem System hinzugefügt.

Bedienung

Nachdem der Projektor erfolgreich hinzugefügt wurde, kann ins Operator Panel gewechselt werden. Hier ist der Status des Projektors ersichtlich, sowie das Ein-/Ausschalten des Geräts möglich. Wenn das Projektor Symbol grau ist, ist dieser ausgeschalten. Wenn dieser hingegen die Farbe Blau hat, ist er eingeschalten.
Zudem kann hier die Quelle des Projektors geändert werden.

Im Parameter Panel kann nochmals die IP-Adresse sowie der Port geändert werden.

Unter dem Reiter „Einstellungen“, kann die Option „Benutzerdefinierte Szenen“ aktiviert werden, wodurch über eine Szene, ein benutzerdefinierter Befehl an den Projektor gesendet werden kann.

Szenen

Die Projektor App bietet folgende Funktionen für Szenen (dann ...):

  • Einschalten: Den Projektor einschalten
  • Ausschalten: Den Projektor ausschalten
  • Benutzerdefinierten Befehl senden (kann im Parameter Panel de-/aktiviert werden): Einen benutzerdefinierten Befehl and den Projektor senden
  • Quelle ändern: Die verwendete Quelle des Projektors ändern

Indoor climate

The app “indoor climate” lets you operate and configure all room climate elements in your system. You also have the pre-defined central functions “all frost protection mode”, “all comfort mode” and “all energy saving mode”.

The app is located under “all apps” – “indoor climate”.

Usage

Clicking on the left-hand area of the object panel switches back and forth between comfort mode and energy saving mode.

You can also select the operating mode using the three buttons located next to each other in the operator panel. The desired temperature can be adjusted in the circle above these buttons via the “+” and “-“ buttons, or you can simply click on the position in the circle that you want.

Configuration

General

Deactivate individual room control
If you have a module type C1144, you can deactivate a connected room control panel with this setting. In this case, only the actual value is taken from the room control panel. All other values are ignored.

External actual value
If you have a module type C1244, you can activate this setting to receive the actual value from another source than a connected PT1000. If you use this setting, you will have to choose the new source in the linkpanel.

Cooling disabled
This setting allows you to deactivate cooling for the connected climate device. Additionally, while this option is active, the cooling mode from the global settings will also be ignored.

Permanent ON/OFF
The valve output can be permanently switched on or off, independently of the current temperature and the current operating mode.

Remove from universal scene
The valve output can be permanently switched on or off, independently of the current temperature and the current operating mode.

Display actual/desired value
This value determines whether the actual or desired value should be displayed in the object panel.

Reserve
Even if not all room climate channels are connected to a module, all four control elements are still displayed for this module. If you want to hide these unconnected control elements, then mark them as reserved. You can unhide them via the app “hardware” (all apps – “hardware”).

Setpoints

The desired values for the various operating modes are defined here. Clicking on the button “use this desired value for the entire room climate” opens up a dialogue with which the desired values in this room climate element can also be used for all other elements.

Presence Rise

If the presence button on the room control panel is pressed, the desired temperature of the room is increased by the defined value and time period.

Temperature Limit

The item “temperature limit” lets you define a temperature limit, i.e. you can react with a scene if the value falls below or exceeds the limit. You can also activate notifications for falling below or exceeding the limit via “notifications for temperature limits”.

Regler

Bei C1144 und C1244 Modulen mit Firmware 4.0 oder höher kann die Art des Reglers eingestellt werden. Dieser kann entweder als Zweipunkt oder PWM Regler konfiguriert werden.

Zweipunkt Regler
Der Zweipunkt Regler ist die einfachste Form eine Heiz- oder Kühl-Regelung zu realisieren. Der Zweipunktregler vergleicht den Istwert mit dem Sollwert und schaltet in Abhängigkeit der Hysterese den Ausgang bei Überschreitung oder Unterschreitung Aus oder Ein. Die Hysterese dient dazu die Schalthäufigkeit (Frequenz) des Ausgangs zu begrenzen.

Folgende Einstellungen können gesetzt werden:

  • Hysterese Heizen
    Die Hysterese beim Heizen definiert den Totbereich zum Umschalten des Zustandes. Bei einem Sollwert von 22° und einer Hysterese von 1°, schaltet die Heizung bereits bei 21.5° ein und erst bei 22.5° wieder aus. Das verhindert das Schwingen des Ausganges.
  • Hysterese Kühlen
    Gleich wie beim Heizen kann auch eine Hysterese zum Kühlen eingestellt werden.

PWM Regler
Der PWM Regler (Pulsweitenmodulations-Regler) ist eine erweiterte Möglichkeit zur Regelung von Heiz- oder Kühlsystemen. Der PWM Regler nützt die Trägheit von Systemen aus, um im Vergleich zum Zweipunktregler (Ein, Aus) sehr viele Ausgangszustände abbilden zu können. Der PWM Regler arbeitet dabei auch nur mit einem digitalen Ausgangssignal, dieses wird jedoch innerhalb einer definierten Periodendauer so geschaltet, dass in Abhängigkeit der Soll-/Ist-Temperaturabweichung der Ausgang mit unterschiedlichen Puls- (Ein) und Pausenzeiten (Aus) angesteuert wird. Ein träges System (z.B.: Thermostellantrieb in einer Fußbodenheizung) kann durch diese Art sehr intelligent von 0-100% geregelt werden.

Beispielhafte Funktionserklärung:
Solltemperatur 22°C, Isttemperatur 21,3° ergibt eine Abweichung von 0,7°C. 0,7 + Offset von 0,2 multipliziert mit einem Kp von 100 ergibt einen Wert von 90%. Der PWM Regler wird in diesem Fall bei einer Periodendauer von 300sec (5min) den Ausgang (Ventil) 270sec aktiv ansteuern (90% von 300sec).

  • Periodendauer
    Die Periodendauer definiert den gesamten Zeitbereich für die Berechnung der Puls- Pausenzeit. Die Periodendauer muss der Zeitdauer für das vollständige Ansprechen des verknüpften Ausgangs entsprechen.
    Beispiel Thermostellantrieb: Die Periodendauer entspricht der Zeit welche vergeht, bis der Stellantrieb nach der Ansteuerung vollständig geöffnet ist.
    Beispiel Infrarotheizung: Die Periodendauer entspricht der Zeit welche vergeht, bis das Panel nach der Ansteuerung die maximale Heizleistung /Wärme abstrahlt.

  • Kp
    Der Verstärkungsfaktor Kp definiert die Verstärkung des berechneten Ausgangswertes (Pulse/Pause) in Abhängigkeit von Soll-/Isttemperatur. Eine Erhöhung von Kp führt bei gleichbleibender Abweichung von Soll-/Isttemperatur zu einem erhöhten Ausgangswert. Kp kann somit als ein Multiplikationsfaktor der Abweichung betrachtet werden.

  • Offset
    Eine reine Multiplikation über den Verstärkungsfaktor Kp würde nicht zum genauen erreichen von Solltemperatur gleich Isttemperatur führen. Der Offset führt somit eine leichte Manipulation der berechneten Temperaturabweichung aus und führt somit zur schnelleren Erreichung der gewünschten Isttemperatur. Der Wert für das Offset sollte im Regelfall immer unter 1°C ausreichend sein.

Expertenmodus

Bei den Schrack Smart Building Automation Klimamodulen C1144 und C1244 mit Firmware Version 4.0 oder höher steht ein Expertenmodus zur Verfügung über welchen die allgemeine Konfiguration des Moduls erfolgt. Dieser muss direkt im Modul unter Hardware konfiguriert werden.

Expertenmodus
Wenn der Expertenmodus aktiviert ist kann der Modus des Moduls und die Ein und Ausgänge entsprechend der tatsächlichen Ein- und Ausgänge konfiguriert werden.
Außerdem werden dann auch in der Detailansicht des Moduls die Ein- und Ausgänge angezeigt.
Konfigurationsmodus
Der Konfigurationsmodus kann auf folgende Werte eingestellt werden, welche weiter unten erklärt werden:

  • 4 Räume (Standard)
  • 2 Räume
  • Universal
  • Ohne Autark Funktion

Durch Auswahl von DI/AI 1-4 können die Eingänge konfiguriert werden.
Istwertquelle
Definiert von wo der Istwert für den Regler kommt. Je nach Modus stehen folgende Werte zur Verfügung:

  • DI/AI 1-4
    Nimmt den Wert des jeweiligen Eingangs
  • Externer Temperaturfühler
    Nimmt den Wert, welcher im Parameter Panel des entsprechenden Raumklimas eingestellt wurde.

Eingangsmodus
Definiert was am Eingang angeschlossen ist. Je nach Modus stehen folgende Werte zur Verfügung:

  • Raumbediengerät
    Standard Schrack Smart Building Automation Raumbediengerät.
  • Raumbediengerät - Nur Temperaturfühler
    Bei Temperaturfühlern an einem C1244 Moduls oder bei Schrack Smart Building Automation Raumbediengeräten welche nur einen Temperaturfühler verbaut haben.
  • Sperrkontakt
    Ein Kontakt welcher die konfigurierten Ausgänge sperrt. Zum Beispiel ein Taupunktwächter zum Sperren der Kühlung.
  • DI/AI
    In diesem Modus kann der Ausgang wie ein Digitaler/Analoger Eingang verwendet werden.

Durch das zusätzliche „L“ bei Raumbediengeräten wird eine Light-Variante symbolisiert. Dabei handelt es sich um einfache Temperaturfühler.

Durch Auswahl von DO 1-4 können die Ausgänge konfiguriert werden.
Ausgangsmodus
Definiert was am Ausgang angeschlossen ist. Je nach Modus stehen folgende Werte zur Verfügung:

  • Ventil Heizen
    Ventil welches nur zum Heizen verwendet wird.
  • Ventil Kühlen
    Ventil welches nur zum Kühlen verwendet wird.
  • Ventil Heizen/Kühlen
    Ventil welches zum Heizen und Kühlen verwendet wird.
  • DO
    In diesem Modus kann der Ausgang wie ein Digitaler Ausgang verwendet werden.

Sperrkontakt
Definiert durch welchen Sperrkontakt das Ventil gesperrt werden soll. Dafür muss ein entsprechender Eingang als Sperrkontakt konfiguriert sein.

Sperrkontakte können nur beim Modul C1144 verwendet werden.

Modus: 4 Räume (Standard)
Dieser Modus eignet sich für Räume in welchem nur ein Ventil zum Heizen und/oder Kühlen verwendet wird. Wie zum Beispiel bei der Standard Fußbodenheizung.
Somit können 4 Räume auf einem Modul konfiguriert werden.

In diesem Modus kann kein Sperrkontakt vergeben werden.

Modus: 2 Räume
Dieser Modus eignet sich für Räume, in welchen zwei getrennte Ventile verwendet werden. Zum Beispiel ein Ventil zum Heizen und ein Ventil zum Kühlen.
Somit können 2 Räume konfiguriert werden.

Hier kann Eingang 2 und Eingang 4 als Sperrkontakt oder Digitaler Eingang verwendet werden.

Modus: Universal
Dieser Modus eignet sich für Räume in welchen ein Mehrstufiges Heiz- oder Kühlsystem vorhanden ist. Zum Beispiel wenn über den Fußboden geheizt und gekühlt wird und zusätzlich über die Decke gekühlt wird oder bei einer gestaffelten Infrarot Heizung über Fußboden, Decke und Wand.

Hier kann für die Eingänge 2-4 die davor liegenden Eingänge als Istwert verwendet werden, wenn zum Beispiel das Raumbediengerät am Eingang 1 angeschlossen wurde. Die anderen Eingänge können dann als Sperrkontakte oder Digitale Eingänge verwendet werden.

In diesem Modus wird pro Regelkreis ein eigener Regler angelegt, um eine erleichterte Bedienung zu erhalten, können diese in einer Zonenregelung zusammengefasst werden.

Zusätzlich ist es durch Klick auf den Verknüpfungs-Button möglich, zwei Kanäle zu einer gemeinsamen Regelung zusammenzufügen um beispielsweise eigene Heiz- und Kühlventile mit einer Regelung verwenden zu können.

Modus: Ohne Autark Funktion
In diesem Modus werden die Regler am Modul deaktiviert. Dann werden die Ein- und Ausgänge wie Digitale Ein- und Ausgänge verwendet und müssen zum Beispiel über die Logik ausgewertet und geschalten werden.

Wenn sich das Modul im Expertenmodus befindet kann in der Anzeige der Kanäle, in den Parametern des Raumbediengerätes oder des Temperaturfühlers eine Korrektur des Istwertes eingestellt werden. Dadurch wird der vom Sensor gemessene Istwert um den eingestellten Wert erhöht/vermindert.

Linking

Links allow you to connect your indoor climate or room control unit with other elements in the Smart Building Automation system.

Window contact
To ensure that heating is suspended when a window is open, any number of windows can be linked using the "add" button. If one of these windows is opened, the indoor climate zone automatically switches to frost protection mode. Once all linked windows are closed again, comfort mode is reactivated.

Settings

The settings for all room climate elements can be found under “all apps” –“settings” – “indoor climate”.

Can cool
If your heating system supports cooling, then you can activate this option. Warning! If your heating is not suitable for cooling, using this option could lead to malfunction. If in doubt, please contact a heating specialist.

Szenen

Das Raumklima bietet folgende Auslöser für Szenen (wenn ...):

  • Für Module bis zur Firmwareversion 3.x:
    -- Geringe Luftfeuchtigkeit erkannt: Die konfigurierte minimale Luftfeuchtigkeit wurde unterschritten.
    -- Hohe Luftfeuchtigkeit erkannt: Die konfigurierte maximale Luftfeuchtigkeit wurde überschritten.
    -- Präsenz wurde aktiv: Präsenztaster am Raumbediengerät wurde gedrückt.
    -- Präsenz wurde inaktiv: Präsenz wurde nach Ablauf der Präsenzzeit wieder inaktiv.

  • Für Module ab der Firmwareversion 4.0:
    -- Geringe Luftfeuchtigkeit erkannt: Die konfigurierte minimale Luftfeuchtigkeit wurde unterschritten.
    -- Hohe Luftfeuchtigkeit erkannt: Die konfigurierte maximale Luftfeuchtigkeit wurde überschritten.
    -- Obere Temperaturgrenze überschritten: Die konfigurierte maximale Temperaturgrenze wurde überschritten.
    -- Untere Temperaturgrenze überschritten: Die konfigurierte minimale Temperaturgrenze wurde unterschritten.
    -- Präsenz wurde aktiv: Präsenztaster am Raumbediengerät wurde gedrückt.
    -- Präsenz wurde inaktiv: Präsenz wurde nach Ablauf der Präsenzzeit wieder inaktiv.

Das Raumklima bietet folgende Funktionen für Szenen (dann ...):
- Auf Energiesparen umschalten: Der Status Energiesparen wird für den Heiz -/Kühlkreis aktiv und die Sollwerte für Energiesparen werden angewendet
- Auf Frostschutz umschalten: Der Status Frostschutz wird für den Heiz -/Kühlkreis aktiv und die Sollwerte für Frostschutz werden angewendet
- Auf Komfortbetrieb umschalten: Der Status Komfortbetrieb wird für den Heiz -/Kühlkreis aktiv und die Sollwerte für Komfortbetrieb werden angewendet
- Auf Modus Heizen umschalten: Der Modus „Heizen“ wird aktiviert (Gerät muss von der globalen Heiz-/Kühlumschaltung ausgenommen sein)
- Auf Modus Kühlen umschalten: Der Modus „Kühlen“ wird aktiviert (Gerät muss von der globalen Heiz-/Kühlumschaltung ausgenommen sein)

Logik

Das Raumklima bietet folgende Möglichkeiten für die Verwendung in Logiken:

  • Für Module bis zur Firmwareversion 3.x:
    -- Ausgang aktiv: Hier können Sie ablesen, ob der Ausgang eingeschalten ist oder nicht.
    -- Fehler: Hier können Sie ablesen, ob ein Fehler vorliegt.
    -- Kühlen: Hier können Sie den Modus des Raumklimas steuern und ablesen. (Steuern ist nur möglich, wenn das Gerät von der globalen Heiz-/Kühlumschaltung ausgenommen ist)
    -- Dauerhaft AUS: Dient zum permanenten ausschalten des Ausgangs.
    -- Dauerhaft EIN: Dient zum permanenten einschalten des Ausgangs.
    -- Automatikbetrieb aktiv: Hier können Sie ablesen, ob der Automatikbetrieb aktiv ist.
    -- Energiesparbetrieb aktiv: Hier können Sie ablesen, ob der Energiesparbetrieb aktiv ist.
    -- Frostschutzbetrieb aktiv: Hier können Sie ablesen, ob der Frostschutzbetrieb aktiv ist.
    -- Komfortbetrieb aktiv: Hier können Sie ablesen, ob der Komfortbetrieb aktiv ist.
    -- Heizanforderung aktiv: Hier können Sie ablesen, ob die Heizanforderung aktiv ist.
    -- Heizfunktion deaktivieren: Dient zum Deaktiveren der Heizfunktion .
    -- Kühlanforderung aktiv: Hier können Sie ablesen, ob die Kühlanforderung aktiv ist.
    -- Kühlfunktion deaktivieren: Dient zum Deaktiveren der Kühlfunktion.

  • Für Module ab der Firmwareversion 4.0:
    -- Ausgang aktiv: Hier können Sie ablesen, ob der Ausgang eingeschalten ist.
    -- Heizfunktion deaktivieren: Dient zum Deaktiveren der Heizfunktion .
    -- Kühlfunktion deaktivieren: Dient zum Deaktiveren der Kühlfunktion.
    -- Luftfeuchtigkeitssensor vorhanden:Hier können Sie ablesen, ob ein Luftfeuchtigkeitssensor vorhanden ist.

Zonenregelung

Mit Klimamodulen ab der Firmware Version 4.0 können die einzelnen Kanäle über eine Zonenregelung gesteuert werden.
Dies ermöglicht das einfachere Bedienen von Räumen welche mehrere Heiz- und/oder Kühlkreise besitzen.

Über „Zonenregelung hinzufügen“ kann eine neue Zonenregelung erstellt werden.

Im Operatorpanel kann über die drei nebeneinander liegenden Buttons die Betriebsart ausgewählt werden. Im Kreis oberhalb dieser Buttons können Sie die Solltemperatur anpassen über die Buttons “+” und “-” bzw. indem Sie auf die gewünschte Stelle im Kreis klicken. Diese werden dann auf alle verknüpften Raumklima Elemente übertragen.

Außerdem wird der aktuelle Status der verknüpften Raumklima Elemente angezeigt.

Im Parameterpanel kann ein Default Wert für die Sollwerte eingestellt werden. Diese werden dann auf alle verknüpften Raumklima Elemente übertragen.

Außerdem können hier Raumklima Elemente verknüpft werden.

Pro Raumklima Element kann ein Sollwertoffset für Heizen und/oder Kühlen vergeben werden. Dieser passt die Sollwerte für das entsprechende Element an.
Ein Offset von 3°C beim Heizen, passt einen Default Sollwert von z.B. 21°C auf 18°C an, dadurch setzt die Heizung erst später ein. Beim Kühlen passt dieser den Sollwert von z.B. 21°C auf 24°C an.

Dadurch kann zum Beispiel erreicht werden, dass bei vorhanden sein einer Decken- und Bodenkühlung, zuerst die Deckenkühlung aktiviert wird. Sollte diese Kühlung nicht ausreichen und die Temperatur steigt weiter, wird auch die Bodenkühlung aktiviert.

Systemmeldungen

Folgende Systemmeldungen können vom Raumklima ausgelöst werden:

Das Raumbediengerät ist defekt! oder Sensor defekt oder nicht angeschlossen!

Dieser Fehler sagt aus, dass der Temperatursensor defekt, falsch oder gar nicht angeschlossen ist.

Dieser Fehler wird sofort erkannt, wenn keine oder ungültige Daten erhalten werden.

In diesem Zustand findet keine Regelung statt und das zugehörige Ventil ist dauerhaft geschlossen.

Es wird zudem eine Benachrichtigung ausgegeben, sobald dieser Fehler erkannt wurde.

Im Object Panel wird als Status ein rotes X angezeigt und der Modus kann nicht geändert werden.
Im Operator Panel wird als Status ein rotes X mit dem Fehlertext angezeigt und die Bedienung ist deaktiviert.

Mögliche Fehlerursache ist eine falsche Verdrahtung oder ein defektes Raumbediengerät bzw. Temperatursensor.

Kein externer Istwert ausgewählt

Dieser Fehler sagt aus, dass ein externer Istwert als Temperaturquelle erwartet wird, aber nicht verknüpft wurde.

Dieser Fehler wird sofort erkannt.

In diesem Zustand findet keine Regelung statt und das zugehörige Ventil ist dauerhaft geschlossen.

Im Object Panel wird als Status ein rotes X angezeigt und der Modus kann nicht geändert werden.
Im Operator Panel wird als Status ein rotes X mit dem Fehlertext angezeigt und die Bedienung ist deaktiviert.

Mögliche Fehlerursache ist, dass im Link Panel kein Externer Istwert verknüpft wurde oder bei Modulen mit der Firmware Version 4.x im Parameter Panel die Temperaturquelle entfernt wurde und keine neue hinzugefügt wurde.

Obere Temperaturgrenze überschritten

Dieser Warnung sagt aus, dass die Ist-Temperatur die obere Temperaturgrenze überschritten hat.

Diese Warnung wird sofort erkannt.

In diesem Zustand findet die Regelung wie gehabt statt.

Es wird zudem eine Benachrichtigung ausgegeben, falls die Option Benachrichtigen wenn Temperaturgrenzen unter- bzw. überschritten unter Benachrichtigungen im Parameter Panel aktiviert wurde.

Untere Temperaturgrenze unterschritten

Diese Warnung sagt aus, dass die Ist-Temperatur die untere Temperaturgrenze unterschritten hat.

Diese Warnung wird sofort erkannt.

In diesem Zustand findet die Regelung wie gehabt statt.

Im Object Panel wird als Status ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird als Status ein gelbes Rufzeichen und ein Warntext angezeigt.

Es wird zudem eine Benachrichtigung ausgegeben, falls die Option Benachrichtigen wenn Temperaturgrenzen unter- bzw. überschritten unter Benachrichtigungen im Parameter Panel aktiviert wurde.

Heizung überprüfen: Hohe Abweichung von Soll- und Isttemperatur

Diese Warnung sagt aus, dass die Ist-Temperatur eine zu große Abweichung zur Soll-Temperatur hat.

Diese Warnung wird nach einer eingestellten Verzögerung erkannt, welche im Parameter Panel unter Benachrichtigungen und Dauer eingestellt wurde.
Diese Warnung wird angezeigt, wenn Kühlfunktion deaktivieren und Heizfunktion deaktivieren nicht aktiviert sind.
Diese Warnung wird angezeigt, wenn die Optionen Warnen wenn Temperaturunterschied bei anderem Betrieb zu hoch ist und Kühlfunktion deaktivieren aktiviert sind und der Modus in Einstellungen Raumklima auf Kühlen gestellt ist.
Diese Warnung wird angezeigt, wenn die Optionen Warnen wenn Temperaturunterschied bei anderem Betrieb zu hoch ist und Heizfunktion deaktivieren aktiviert sind und der Modus in Einstellungen Raumklima auf Heizen gestellt ist.

In diesem Zustand findet die Regelung wie gehabt statt.

Im Object Panel wird als Status ein gelbes Rufzeichen angezeigt.
Im Operator Panel wird als Status ein gelbes Rufzeichen und ein Warntext angezeigt.

Es wird zudem eine Benachrichtigung ausgegeben, falls die Option Benachrichtigen wenn Temperaturunterschied zu hoch unter Benachrichtigungen im Parameter Panel aktiviert wurde.

Gesperrt

Dieser Status sagt aus, dass die Regelung gesperrt ist.

Dieser Status wird sofort erkannt, sobald einer der nachfolgenden Zustände eintrifft:

  • Unter Hardware beim jeweiligen Modul ein Sperrkontakt definiert wurde, welcher aktuell aktiv ist
  • Sich das Raumklima im Modus Heizen befindet und die Option Heizfunktion deaktivieren im Parameter Panel aktiviert wurde
  • Sich das Raumklima im Modus Kühlen befindet und die Option Kühlfunktion deaktivieren im Parameter Panel aktiviert wurde

In diesem Zustand findet keine Regelung statt und das zugehörige Ventil ist dauerhaft geschlossen.

Im Object Panel wird die Temperatur und darüber ein Sperrzeichen angezeigt und der Modus kann nicht geändert werden.
Im Operator Panel wird als Status Gesperrt angezeigt.
Im Parameter Panel wird falls ein Sperrkontakt verknüpft wurde, dieser unter Sperrkontakt angezeigt.

Mögliche Ursachen der Sperre sind:

  • Ein verknüpfter Sperrkontakt ist aktiv (z.B. Kondensatwächter)
  • In den Einstellungen wurde die aktive Funktion (Heizen oder Kühlen) deaktiviert

Dauerhaft EIN

Dieser Status sagt aus, dass das zugehörige Ventil dauerhaft komplett geöffnet ist.

Dieser Status wird sofort erkannt, sobald die Option Dauerhaft EIN im Parameter Panel aktiviert wurde.

In diesem Zustand findet keine Reglung statt, das zugehörige Ventil ist dauerhaft komplett geöffnet.

Im Object Panel wird ein Kreis angezeigt und der Modus kann nicht geändert werden.
Im Operator Panel wird als Status Dauerhaft EIN angezeigt.

Dauerhaft AUS

Dieser Status sagt aus, dass das zugehörige Ventil dauerhaft komplett geschlossen ist.

Dieser Status wird sofort erkannt, sobald die Option Dauerhaft AUS im Parameter Panel aktiviert wurde.

In diesem Zustand findet keine Regelung statt und das zugehörige Ventil ist dauerhaft geschlossen.

Im Object Panel wird ein durchgestrichener Kreis angezeigt und der Modus kann nicht geändert werden.
Im Operator Panel wird als Status Dauerhaft AUS angezeigt.

REST API

Starting with version 1.4, the Smart Building Automation system provides a REST API at "http://[Smart_Building_Automation_IP]/api". The following steps are required to use the REST API.

Preparation

  • Navigate to "all apps" – "settings" – "rest service" in the user interface of the Smart Building Automation system.
  • Enter the credentials and generate a hash. Save the generated hash, as it is required for the next step.

Authentication

Authentication is required to send requests to the REST API. A token is used for this purpose and is provided after a successful login via the REST API.

  • Send a POST request to "http://[Smart_Building_Automation_IP]/login" with the following header parameters:
    • x-elocs-username: [Username]
    • x-elocs-password: [Hash]

The token x-elocs-token is returned in the response and automatically set as a cookie. It is used to authenticate all subsequent requests.

Depending on where the requests to the Smart Building Automation system are sent from, the cookie is used automatically. Otherwise, the token must be included in the header of every request: Cookie:token=[Token].

Requests

The Smart Building Automation REST API can be used to retrieve the current status of individual functions within the system and to control them. The following requests are available:

GET: apps
"http://[Smart_Building_Automation_IP]/api/apps"
Returns a list of all apps.

GET: apps/{fullName}
Returns detailed information about the requested app.

GET: instances
Returns a list of all instances.

GET: instances/{instanceId}
Returns detailed information about the requested instance.

GET: instances/{instanceId}/{action}
Returns the current value of the requested property of a specific instance, for example, the current state of a light.

POST: instances/{instanceId}/{action}
Calls a method of the specified instance.

A test interface is available at "http://[Smart_Building_Automation_IP]/api", where all listed requests can be tested.

Examples

The following example shows how to switch a light using the REST API.

First, the required authentication steps must be completed (see the "Preparation" and "Authentication" sections). The resulting token can then be used to send the required requests and commands.

First, a GET request is sent to "http://[Smart_Building_Automation_IP]/api/instances". The response contains a list of all instances currently available in the Smart Building Automation system.

{
  "statusCode": 200,
  "statusText": "success",
  "data": [
    {
      "ID": "SC1_M04.Light1",
      "ClassName": "SmartCOM.Light.Light",
      "Name": "Roomlight",
      "Group": "AreaOutdoor"
    },
    ...
  ]
}

Since a light is to be switched, "Roomlight" is selected. Its "ClassName", "SmartCOM.Light.Light", can then be used to send a GET request to "http://[Smart_Building_Automation_IP]/api/apps/SmartCOM.Light.Light" and retrieve the available methods and properties.

{
  "statusCode": 200,
  "statusText": "success",
  "data": {
    "methods": [
      {
        "parameter": [],
        "name": "SwitchOn",
        "type": 0,
        "derived": false,
        "tags": [
          "linkable"
        ],
        "returnType": "void",
        "description": "switch light on",
        "isStatic": false
      },
      ...
    ],
    "properties": [
      {
        "name": "IsOn",
        "type": "boolean",
        "remark": "light switched on",
        "declaration": "2",
        "derived": true,
        "parameter": false,
        "tags": [
          "linkable"
        ],
        "isStatic": false
      },
      ...
    ],
    "fullName": "SmartCOM.Light.Light",
    "displayName": "Light",
    "autoStart": false
  }
}

Next, a POST request is sent to "http://[Smart_Building_Automation_IP]/api/instances/SC1_M04.Light1/SwitchOn" with the following parameters in the header:

  • instanceId: SC1_M04.Light1
  • action: SwitchOn
  • body: [ ]

This calls the specified method and switches the light on. The current status can be checked by sending a GET request to "http://[Smart_Building_Automation_IP]/api/instances/SC1_M04.Light1/IsOn". The response contains the current status, in this case "true".

{
  "statusCode": 200,
  "statusText": "success",
  "data": true
}

REST Client

Mit der App „REST Client“ können Funktionen auf Geräten ausgeführt werden, für die keine eigene App im Smart Building Automation System zur Verfügung steht, welche jedoch über eine REST-Schnittstelle verfügen.

Für die Verwendung des REST Clients sind grundlegende Kenntnisse über die Funktionsweise von REST sowie über die Schnittstelle des anzubindenden Geräts erforderlich.
Eine kurze Einführung in REST ist hier zu finden.

Die App „REST Client“ ist unter „Alle Apps“ zu finden.

Erstellen

Um einen neuen REST Client zu erstellen, navigieren Sie zur App und wählen Sie „Client hinzufügen“.

Konfiguration

In den Einstellungen können allgemeine Einstellungen für den REST Client konfiguriert werden, beispielsweise die Verbindungsdaten.

Verbindung
HTTP / HTTPS
Hier kann festgelegt werden, ob der REST Service über eine verschlüsselte Verbindung (HTTPS) zur Verfügung steht.

Host
Hier kann die IP- oder Webadresse des REST Services angegeben werden.

Port
Hier kann der Port des REST Services angegeben werden.

Basis URL
Viele REST Services verwenden einen festen Basispfad, an den alle weiteren Anfragen angehängt werden. Dieser kann hier angegeben werden, z. B. „/api“.

Self-Signed Zertifikate zulassen
Ist diese Option aktiviert, werden Zertifikatsfehler ignoriert. Dadurch kann auch auf APIs mit einem selbstsignierten oder abgelaufenen Zertifikat zugegriffen werden.

Globale Header
Hier können Header angegeben werden, die bei jeder Anfrage mitgesendet werden sollen. Diese müssen als JSON-String angegeben werden.

Authentifizierung
Es stehen drei Authentifizierungsmethoden zur Verfügung: keine, Basic und Benutzerdefiniert.

Keine
Bei der Auswahl „Keine“ erfolgt vor dem Senden von Anfragen keine Authentifizierung.

Basic
Bei der Authentifizierungsmethode „Basic“ können ein Benutzername und ein Passwort mitgesendet werden. Diese Methode kann verwendet werden, wenn der REST Service Basic Authentication unterstützt.

Benutzerdefiniert
Für andere Authentifizierungsmethoden steht eine benutzerdefinierte Authentifizierung zur Verfügung.

  • Methode: Hier kann festgelegt werden, ob die Authentifizierung über GET oder POST gesendet wird.
  • Login URL: Hier kann der Pfad für die Anmeldung angegeben werden. Dieser ist unabhängig von der Basis URL.
  • Header: Hier können Header für die Login-Anfrage angegeben werden. Diese müssen als JSON-String angegeben werden.
  • Token: Hier kann festgelegt werden, ob der benötigte Token in der Antwort des REST Services im Header oder im Body enthalten ist.
  • Position: Hier wird die Position des Tokens in der Antwort angegeben, z. B. „login-token“ im Header.
  • Inkludieren in: Hier kann festgelegt werden, ob der ausgelesene Token bei weiteren Anfragen im Header oder im Body mitgesendet wird.
  • Position: Hier wird die Position angegeben, an der der Token bei weiteren Anfragen eingefügt wird, z. B. „x-token“ im Header.
  • Periodisch Einloggen: Hier kann festgelegt werden, ob eine periodische Anmeldung erfolgen soll und in welchem Abstand.

Webhooks

Webhooks können verwendet werden, um Ereignisse als Auslöser für Szenen im Smart Building Automation System zu verwenden. Beispielsweise kann über eine 2N Innensprechstelle ein Button definiert werden, der die Eingangstür öffnet. Dazu wird in der Innensprechstelle die URL hinterlegt, die bei aktivierten Webhooks in den Anfragen des REST Clients angezeigt wird.

Um Webhooks für den REST Client zu aktivieren, muss die Option „Webhooks aktivieren“ ausgewählt werden.
Unter „Webhook Authentifizierung“ kann die gewünschte Authentifizierungsmethode festgelegt werden.
Folgende Optionen stehen zur Verfügung:

  • Default: Hier können die im Smart Building Automation System angelegten Benutzer verwendet werden. Siehe REST Service Authentifizierung
  • Basic: Hier können die im Smart Building Automation System angelegten Benutzer verwendet werden. Siehe Basic Authentication
  • Digest: Hier können ein eigener Benutzername und ein eigenes Passwort vergeben werden. Siehe Digest Authentication
  • Keine: Für die Verwendung des Webhooks ist keine Authentifizierung erforderlich.

Damit die Webhooks verwendet werden können, müssen diese zusätzlich bei den jeweiligen Anfragen aktiviert werden. Weitere Informationen dazu sind weiter unten zu finden.

Damit die Einstellungen übernommen werden, muss der Button „Einstellungen übernehmen“ ausgewählt werden.

Über den Button „Anfragen bearbeiten“ wird die Ansicht der Anfragen für den REST Client geöffnet. Hier können neue Anfragen angelegt und bestehende Anfragen bearbeitet werden.

Über „Anfrage hinzufügen“ kann eine neue Anfrage erstellt werden.

Folgende Typen stehen zur Auswahl:

  • REST Anfrage: Ermöglicht das Senden von Befehlen und allgemeinen Anfragen an einen REST Service, ohne die Rückmeldung weiterzuverarbeiten.
  • REST Boolean: Ermöglicht das Abfragen von Boolean-Werten eines REST Services, die anschließend im System weiterverwendet werden können.
  • REST Nummer: Ermöglicht das Abfragen von Zahlenwerten eines REST Services, die anschließend im System weiterverwendet werden können.
  • REST Text: Ermöglicht das Abfragen von Textwerten eines REST Services, die anschließend im System weiterverwendet werden können.

In den Einstellungen einer Anfrage kann festgelegt werden, welche Daten gesendet werden sollen.

Methode
Hier kann die HTTP-Methode für die Anfrage ausgewählt werden.

Url
Hier kann der Pfad angegeben werden, an den die Anfrage gesendet wird. Dieser wird an den Host und die Basis URL angehängt.

Header
Hier können Header angegeben werden, die mit der Anfrage gesendet werden sollen. Diese müssen als JSON-String angegeben werden.

Body
Hier kann der Inhalt angegeben werden, der im Body der Anfrage gesendet werden soll. Der Body muss als JSON-String angegeben werden.

Zyklisch
Hier kann festgelegt werden, ob die Anfrage zyklisch gesendet werden soll und in welchem Abstand.

Bei Fehler erneut versuchen
Ist diese Option aktiviert, kann festgelegt werden, wie oft die Anfrage bei einem Fehler erneut gesendet werden soll. Als Fehler gilt dabei eine Antwort ohne Statuscode zwischen 200 und 299.

Benutzerdefiniertes Timeout
Ist diese Option aktiviert, kann ein Timeout in Millisekunden festgelegt werden, nach dessen Ablauf die Anfrage abgebrochen wird.

Verwende JSON Parse
Liegen die Rückgabedaten im JSON-Format vor, kann mit dieser Funktion auf einzelne Properties im JSON-Objekt zugegriffen werden. Besteht das Objekt aus mehreren Ebenen oder Arrays, kann der Selektor entsprechend erweitert werden (z. B. id.name, id[3].value, ...).

Einheit
Bei Zahlenwerten kann zusätzlich eine Einheit angegeben werden, die bei der Anzeige des Werts ergänzt wird.

Über „Anfrage schicken“ kann die Anfrage testweise gesendet werden. Dadurch kann geprüft werden, ob die Einstellungen korrekt sind. Die Antwort wird anschließend angezeigt.

Zum Testen des REST Clients kann die Webseite „https://jsonplaceholder.typicode.com/“ verwendet werden. Dieser Webserver stellt JSON-Testdaten in verschiedenen Formaten zur Verfügung (z. B. https://jsonplaceholder.typicode.com/users).

Webhook

Sind Webhooks im REST Client aktiviert, kann für jede Anfrage ein eigener Webhook aktiviert werden. Für jede Anfrage wird eine eigene URL erzeugt, wodurch unterschiedliche Ereignisse umgesetzt werden können.

Zum Aktivieren muss die Option „Webhook aktivieren“ ausgewählt werden.
Anschließend kann die Methode festgelegt werden. Diese bestimmt, mit welcher HTTP-Methode die Anfrage an das Smart Building Automation System gesendet wird.

Die Änderungen müssen anschließend über den Button „Speichern“ gespeichert werden.

Danach kann der erzeugte Link kopiert und im entsprechenden Service hinterlegt werden.

In Szenen steht anschließend der Auslöser (Wenn ...) „Webhook wurde aufgerufen“ zur Verfügung.

Webhooks stehen derzeit nur im lokalen Netzwerk zur Verfügung.

Bedienung

Im Operator Panel des REST Clients werden alle angelegten Anfragen angezeigt. Diese können direkt gesendet werden.

Auch unter „Anfragen bearbeiten“ können die angelegten Anfragen direkt gesendet werden.

Die Anfragen können auch in anderen Bereichen des Smart Building Automation Systems verwendet werden, beispielsweise in Szenen.

Schlotterer Funkerweiterung

Neben der kabelgebundenen Anbindung von Beschattungen über Beschattungsmodule können auch funkbasierte Beschattungselemente der Firma Schlotterer in das Smart Building Automation System integriert werden.

Erstellen

Voraussetzung zum Einlernen bzw. Steuern von Beschattungselementen ist der USB-Transmitterstick.
Dieser muss am USB-Steckplatz am Controller (USB4) angeschlossen werden.

Zusätzlich muss der Stick mindestens über die Version 3.04 verfügen. Dies kann im SettingsPanel überprüft werden. Angeschlossene Erweiterungen finden Sie unter „Alle Apps“ - „Einstellungen“ - „Schlotterer“.

Wurde der Stick erfolgreich verbunden, können Sie mit dem Einlernen neuer Kanäle beginnen. Beachten Sie, dass maximal 10 Elemente gleichzeitig eingelernt werden können. Es dürfen somit nur maximal 10 Elemente gleichzeitig ein- und ausgesichert werden um den Einlernvorgang bei diesen Elementen zu starten.

Starten Sie den Einlernvorgang über den Button „Neuen Kanal einlernen“. Ein einfacher Wizard führt Ihnen nun durch die notwendigen Schritte.

Für das neue Beschattungselement wird automatisch der nächste freie Kanal verwendet.

Außerdem wird beim Einlernvorgang automatisch erkannt, ob der Antrieb ein Rollladen-bzw. Raffstore-Motor ist. Aus dieser Information wird danach die Bedienoberfläche erstellt.

Für die Steuerung der Retrolux-Sonderfunktionen, kann nach dem Einlernvorgang in den Einstellungen der Lamellentyp ausgewählt werden. Zudem verfügt die Bedienoberfläche, je nach gewähltem Typ, über die Möglichkeit in Arbeitsstellung bzw. Geschlossene Stellung zu fahren.

Konfiguration

Bestimmung des Typs

Schlotterer Beschattungselemente sind in unterschiedlichen Ausführungen erhältlich. Je nach Typ stehen verschiedene Funktionen zur Verfügung. In den Einstellungen kann der Typ der Raffstoreelemente über die Form der Lamelle erkannt werden.

Hierfür stehen drei verschiedene Lamellentypen zur Auswahl: 80R, 80d und 92Z. Die Typen 80R und 92Z entsprechen einer herkömmlichen Jalousie, der Typ 80d entspricht einer Schlotterer Jalousie welche auch in der Ausführung mit Arbeitsstellung verfügbar ist.
Um zu erkennen welche Jalousie Sie verwenden hilft Ihnen ein Wizard, mit dem Sie anhand der Bewegung der Lamelle erkennen, um welchen Jalousie-Typ es sich handelt.

Fahrzeiten berechnen:

Alle Beschattungselemente besitzen Endpositionen, welche bei der Installation eingestellt werden. Um die korrekte Position des Elements garantieren zu können, müssen die Fahrzeiten über den Button „Fahrzeiten berechnen“ einmalig konfiguriert werden. Der Ablauf erfolgt automatisch und die Endpositionen sind anschließend korrekt eingestellt.

Verfügbare Funktionen

Rollladen
Der Rollladen bietet Funktionen zum Öffnen, Schließen, Stoppen, Positionieren und das Positionieren auf definierte Favoritenpositionen.
Die Favoritenpositionen können in den Einstellungen der Jalousie konfiguriert werden. Dabei werden Sie durch einen Wizard geführt, welcher Ihnen beim Einlernen unterstützt.

Standard Jalousie
Die Standard Jalousie bietet Funktionen zum Öffnen, Schließen, Stoppen, Positionieren, Tippen Auf und Tippen Zu.

80d mit Arbeitsstellung
Die Jalousie 80d mit Arbeitsstellung bietet zusätzlich zur Standard Jalousie die Funktionen „Arbeitsstellung“ und „Geschlossen“. Beim Modus „Arbeitsstellung“ bleibt die Lamelle immer der Jalousieposition entsprechend geöffnet. Im Modus „Geschlossen“ schließt die Jalousie und Lamelle komplett.

80d ohne Arbeitsstellung
Die Jalousie 80d ohne Arbeitsstellung bietet zusätzlich zur Standard Jalousie die Funktionen „Lichtlenkung“ und „Aufwenden“. Die Funktion „Lichtlenkung“ schließt die Jalousie und öffnet die Lamelle. Die Funktion „Aufwenden“ belässt die Jalousie auf der aktuellen Position und wendet die Lamelle auf.

Bei Rollläden und Standard Jalousien können zwei Positionen angesteuert werden (Zwischenposition und Wende-/Lüftungsposition), welche vorkonfiguriert sind, bzw. über den Funksender eingelernt werden können.
Weitere Informationen erhalten Sie über die entsprechenden Anleitungen unter https://www.elero.de/de/downloads-service/downloads/.

Samsung

Die Samsung App ermöglicht die Einbindung von Samsung Klimageräten in das Smart Building Automation System.

Die „Samsung App“ ist unter „Alle Apps“ - „Samsung“ zu finden.

Konfiguration

Bei der Inbetriebnahme sicherstellen, dass das Klimagerät über das Gateway und Modbus RTU mit dem Smart Building Automation System verbunden ist. Zusätzlich muss am Klimagerät die gewünschte Geräte-Adresse eingestellt sein.

Um das Gateway und die Klimageräte mit dem Smart Building Automation System zu verbinden, zur entsprechenden App navigieren und „Gateway hinzufügen“ auswählen.

Nach der Auswahl von „Gateway hinzufügen“ öffnet sich ein Konfigurationsassistent, der durch die erforderlichen Einstellungen führt.

Im ersten Schritt muss die Modbus RTU Schnittstelle ausgewählt werden, an der das Gateway angeschlossen ist.

Wird die gewünschte Schnittstelle nicht angezeigt, sicherstellen, dass an dieser Schnittstelle keine anderen Modbus RTU Geräte mit abweichenden Verbindungseinstellungen konfiguriert sind.

Nach der Auswahl der Schnittstelle muss die Geräte-Adresse ausgewählt werden. Dabei dieselbe Geräte-Adresse auswählen, die auch am Klimagerät eingestellt ist.

Ist die gewünschte Adresse nicht verfügbar, ist an dieser Schnittstelle bereits ein Gerät mit dieser Adresse konfiguriert. In diesem Fall eine freie Adresse auswählen und am Klimagerät dieselbe Adresse einstellen.

Achtung: Nach dem Ändern der Geräte-Adresse muss das Klimagerät häufig kurz spannungslos geschaltet werden, damit die neue Adresse übernommen wird.

Nach der Auswahl der Geräte-Adresse werden die Modbus RTU Einstellungen für die Verbindung zusammengefasst. Überprüfen, ob die angezeigten Einstellungen mit der Konfiguration des Geräts übereinstimmen.

Im nächsten Schritt wird die Verbindung zum Gateway überprüft. Kann auch nach mehreren Versuchen keine Verbindung hergestellt werden, die Verkabelung sowie die ausgewählte Schnittstelle und Geräte-Adresse überprüfen.

Nach erfolgreicher Verbindung zum Gateway wird nach den angeschlossenen Innenstationen gesucht. Werden nicht alle vorhandenen Innenstationen gefunden, sicherstellen, dass diese eingeschaltet und mit dem Gateway verbunden sind. Über „Erneut suchen“ kann die Suche erneut gestartet werden. Auch später kann jederzeit nach weiteren Innenstationen gesucht werden.

Nach Abschluss des Konfigurationsassistenten werden das Gateway und die zugehörigen Innenstationen automatisch angelegt und sind einsatzbereit. Nach wenigen Sekunden sollten die Daten der Geräte angezeigt werden.

Bedienung

Wurden die Samsung Klimageräte erfolgreich in das Smart Building Automation System eingebunden, stehen mehrere Bedienelemente zur Verfügung.

Die Solltemperatur kann eingestellt, das Gerät ein- oder ausgeschaltet und der Betriebsmodus geändert werden.

Bei der Meldung „Bitte Filter reinigen!“ muss zunächst die Filterreinigung direkt am Klimagerät durchgeführt werden. Anschließend muss die Filterreinigung entweder am Klimagerät oder im System in den Filterreinigungseinstellungen des jeweiligen Innengeräts bestätigt werden.

Der Lüftungsmodus kann von „Automatisch“ auf „Manuell“ geändert werden. Im manuellen Modus kann die gewünschte Lüfterstufe eingestellt werden.

Für die Luftstromrichtung kann das vertikale Schwingen des Innengeräts aktiviert werden.

Viele Innengeräte unterstützen die Funktion „Windfrei“. Bei aktivierter Funktion wird die Klappe des Innengeräts geschlossen und die gekühlte Luft strömt durch die Öffnungen der Klappe. Die Funktion wird nicht von allen Klimageräten unterstützt.

Alle Einstellungen können auch über Szenen gesteuert werden. So können beispielsweise die Lüfterstufe oder die Solltemperatur geändert werden, sobald die festgelegten „Wenn“-Bedingungen erfüllt sind.

Szenen

Die Samsung App bietet folgende Funktionen für Szenen (Dann…):

  • Einschalten: Das Klimagerät wird eingeschaltet.
  • Ausschalten: Das Klimagerät wird ausgeschaltet.
  • Einschalten mit Optionen: Das Klimagerät wird eingeschaltet und Optionen werden gesetzt.
  • Leise-Betrieb aktivieren: Das Klimagerät schaltet die Lüfterstufe auf Leise“.
  • Lüfterstufe setzen: Das Klimagerät schaltet die gewünschte Lüfterstufe.
  • Luftstromrichtung setzen: Das Klimagerät schaltet die gewünschte Luftstromrichtung.
  • Modus für alle setzen: Alle Klimageräte schalten auf den gewünschten Betriebsmodus.
  • Solltemperatur: Das Klimagerät übernimmt die Solltemperatur.
  • Vertikale Luftverteilung aktivieren: Das Klimagerät aktiviert die vertikale Luftverteilung.

Smart Meter

Mit der App „Smart Meter“ können Sie Ihren Energiebedarf überwachen.

Sie finden die Smart Meter App unter „Alle Apps“ - „Smart Meter"

Vorbereitung

Vor der Konfiguration des Smart Meters sind folgende Voraussetzungen zu erfüllen:

  • Der Smart Meter muss über eine Modbus-RTU-Schnittstelle mit dem System verbunden sein.
  • Die am Gerät eingestellte Geräteadresse darf maximal 16 betragen.

Konfiguration

Um den Smart Meter mit dem Smart Building Automation System zu verbinden, zur entsprechenden App navigieren und „Smart Meter hinzufügen“ auswählen.

Nach der Auswahl von „Smart Meter hinzufügen“ öffnet sich ein Konfigurationsassistent, der durch die erforderlichen Einstellungen führt.

Im ersten Schritt muss die Modbus RTU Schnittstelle ausgewählt werden, an der der Smart Meter angeschlossen ist.

Wird die gewünschte Schnittstelle nicht angezeigt, sicherstellen, dass an dieser Schnittstelle keine anderen Modbus RTU Geräte mit abweichenden Verbindungseinstellungen konfiguriert sind.

Nach der Auswahl der Schnittstelle wird automatisch nach allen angeschlossenen Smart Metern gesucht. Den gewünschten Smart Meter auswählen, um diesen mit dem Smart Building Automation System zu verbinden.

Wird der angeschlossene Smart Meter nicht gefunden, kann die Suche über „Erneut suchen“ erneut gestartet werden.

Wird der Smart Meter weiterhin nicht gefunden, sicherstellen, dass dieser eingeschaltet und mit der ausgewählten Schnittstelle verbunden ist. Zusätzlich überprüfen, ob die Modbus RTU Anschlüsse A und B korrekt angeschlossen und nicht vertauscht sind.

Nach Abschluss des Konfigurationsassistenten wird der Smart Meter automatisch angelegt und ist einsatzbereit. Nach wenigen Sekunden sollten die Daten des Smart Meters angezeigt werden.

Bedienung

Im Object Panel wird die Aktuelle Leistung angezeigt. Weiters ist sofort erkennbar, ob gerade Strom vom Netz bezogen wird oder in dieses eingespeist wird.

Im Operator Panel wird der aktuelle Bezug oder die aktuelle Einspeisung visuell dargestellt.

Unter „Energiebilanz“ werden der gesamte Netzbezug sowie der Netzbezug der letzten 24 Stunden dargestellt. Wurde mit dem Smart Meter auch in das Netz eingespeist, so wird auch die gesamte Einspeisung sowie die Einspeisung der letzten 24 Stunden dargestellt.

Zusätzlich kann mithilfe eines Histogramms der Bezug, bzw. die Einspeisung, über verschiedene Zeiträume betrachtet werden.

Der Jahresvergleichswert des Smart Meters zeigt anhand eines einzigen Kennwerts, wie sich der aktuelle Jahresstromverbrauch im Vergleich zum Vorjahr verändert hat.

Im Parameter Panel wird der Verbindungsstatus zum Smart Meter dargestellt.

Zusätzlich können alle Messdaten des Smart Meters betrachtet werden.

Sprachausgabe

Die Sprachausgabe ermöglicht es, eingegebene Texte über die am Soundmodul angeschlossenen Lautsprecher wiederzugeben.

„Die App ist unter 'Einstellungen' - 'Sprachausgabe' zu finden.“

Konfiguration

Bevor Sie konfigurierte Texte über Ihr Soundmodul wiedergeben können, sollten Sie zuerst bestimmen, welche Lautsprecher dafür verwendet werden sollen. Dies können Sie in den Einstellungen der Sprachausgabe tun.

Hier haben Sie außerdem die Möglichkeit einen Signalton zu aktivieren, der vor jeder Sprachausgabe abgespielt wird.

Bedienung

In der Bedienoberfläche der Sprachausgabe können Sie den Text eingeben, der gesprochen werden soll. Außerdem ist es möglich, die Lautstärke der Ansage einzustellen.

Über den Button „Sprechen“ wird die Wiedergabe auf den von Ihnen ausgewählten Lautsprechern gestartet. Darüber hinaus können Sie die Sprachausgabe auch in selbst erstellten Szenen verwenden, um Texte wiederzugeben.

Szenen

Die Sprachausgabe bietet folgende Funktionen für Szenen (dann ...):

  • Sprechen: Der eingegebene Text wird mit festgelegter Lautstärke gesprochen

Sprechanlage 2N

Diese App ermöglicht es Türsprechanlagen der Marke 2N in das Smart Building Automation System zu integrieren.

Die App ist unter „Alle Apps“ - „Sprechanlage“ zu finden.

Konfiguration

Damit eine 2N Sprechanlage mit dem Smart Building Automation System verwendet werden kann, muss diese zuerst folgendermaßen über die Weboberfläche konfiguriert werden:

  • Einen beliebigen Browser öffnen und die IP-Adresse der 2N Sprechanlage eingeben.
  • Mit dem Admin-Benutzer anmelden (Standardpasswort: 2n).
  • In den Einstellungen zu „Services“ > „HTTP API“ navigieren.
  • Bei allen Services im Feld „Authentication“ die Option „Basic“ auswählen und anschließend auf „Save“ klicken.
  • Zum Tab „Account 1“ navigieren und einen neuen Benutzer anlegen. Dieser wird für die Anmeldung im Smart Building Automation System verwendet.
  • Die Checkbox „Account Enabled“ aktivieren.
  • Unter „System Access“ die Checkboxen „Monitoring“ und „Control“ aktivieren.
  • Unter „Camera Access“ die Checkbox „Monitoring“ aktivieren.
  • Unter „Phone/Call Access“ die Checkbox „Monitoring“ aktivieren.
  • Auf „Save“ klicken.

Soll die Tür über einen PIN-Code geöffnet werden, kann dieser unter „Directory“ > „Users“ beim entsprechenden Benutzer unter „User Codes“ > „PIN Code“ angelegt werden.

Um die Türsprechanlage in das Smart Building Automation System einbinden zu können, muss sich diese im selben Netzwerk wie das System befinden.

Sobald die Türsprechanlage montiert und mit dem Netzwerk verbunden ist, kann diese in das System eingebunden werden.

Dazu über den entsprechenden Button eine neue Sprechanlage anlegen. Im daraufhin angezeigten Popup wird automatisch nach der Türsprechanlage gesucht. Sobald die Türsprechanlage aufgelistet wird, kann diese ausgewählt und hinzugefügt werden.

Wird die Türsprechanlage nicht automatisch gefunden, kann diese über den Button „Manuell“ angelegt werden. In diesem Fall wird die IP-Adresse der Türsprechanlage benötigt und muss in den Einstellungen eingetragen werden.

Der im Popup abgefragte Benutzername und das Passwort müssen den Zugangsdaten entsprechen, die unter „HTTP API“ in der 2N Konfiguration angelegt wurden.

Wurde die Sprechanlage automatisch im Netzwerk gefunden und hinzugefügt, muss die IP-Adresse in den Einstellungen nicht mehr angegeben werden.

Die Sprechanlage wird direkt nach dem Anlegen vom System konfiguriert.

Wurde die Sprechanlage manuell angelegt, muss die IP-Adresse in den Einstellungen eingetragen werden. Benutzername und Passwort sind bereits ausgefüllt, können jedoch jederzeit geändert werden, falls die Zugangsdaten in der Türsprechanlage angepasst wurden.

Unter dem Punkt „IP Adresse“ kann eine statische IP-Adresse vergeben werden.

Bedienung

Wurde die Verbindung mit der Sprechanlage erfolgreich hergestellt sehen Sie im OperatorPanel das aktuelle Videobild.

Szenen

Die Sprechanlage bietet folgende Auslöser für Szenen (wenn ...):
- Klingeltaste wurde gedrückt: Die Klingeltaste an der Außenstelle wurde betätigt
- Türöffner aktiviert: Über den PIN wurde der Türöffner aktiviert

Fehlersuche

Sollte es zu Problemen mit der Sprechverbindung kommen, sind nachfolgend die häufigsten Problemlösungspunkte beschrieben:

1. Prüfen Sie korrekten Netzwerkeinstellung der Sprechanlage
Führen Sie dazu als erstes einen Verbindungstest im Bereich „Einstellungen->Netzwerk“ durch. Die URL „www.google.at“ sollte erreichbar sein (100%). Damit ist sichergestellt, dass der Controller über eine korrekte IP-Konfiguration verfügt und auch die Namensauflösung im Internet funktioniert. Sollte der Verbindungstest fehlschlagen, prüfen Sie bitte die getätigten Einstellungen. Als DNS-Server kann alternativ auch der öffentlich verfügbare Google-DNS verwendet werden, dieser ist immer unter der IP 8.8.8.8 erreichbar.
Prüfen Sie nun ob diese Einstellungen (Subnetzmaske, Standardgateway und DNS-Server) auch in der Sprechanlage gleich übernommen wurden. (siehe Screenshots nachfolgend).

2. Teilweise müssen explizite Port-Einstellungen beim Internet-Router gemacht werden
Die Router verfügen meist über die Einstellung von Port-Trigger, Port-Forwarding oder Virtuelle Server. Im Hintergrund ist dabei häufig dasselbe gemeint. Navigieren Sie in diesen Bereich und konfigurieren Sie dann folgenden Einstellungen:

  1. Regel: Name „SIP“, Port-Eingang 5060, Port Ausgang 5060 (TCP und UDP)
  2. Regel: Name „SIP_RTP“ Ports-Eingang 7000-9900, Ports Ausgang 7000-9900 (TCP und UDP)

Die Regeln sollen nur für die IP-Adresse der Sprechanlage gelten.
(siehe Screenshots nachfolgend).

3. Teilweise muss SIP-ALG beim Internet-Router deaktiviert werden
Falls der Router über die Einstellung SIP-ALG (Application Layer Gateway) meist im Bereich Sicherheit verfügt, muss diese Option deaktiviert werden (siehe Screenshots nachfolgend).

Intercom

Erstellen

Um die Türsprechanlage in das Smart System einbinden zu können, muss sich diese im selben Netzwerk befinden.

Sobald die Türsprechanlage montiert und mit dem Netzwerk verbunden ist, kann diese in das System eingebunden werden.

Dazu über den entsprechenden Button eine neue Sprechanlage anlegen. Im daraufhin angezeigten Popup wird automatisch nach der Türsprechanlage gesucht. Sobald diese aufgelistet wird, kann sie ausgewählt und hinzugefügt werden.

Wird die Türsprechanlage nicht automatisch gefunden, kann diese über den Button „Manuell“ angelegt werden. In diesem Fall wird die IP-Adresse der Türsprechanlage benötigt und muss in den Einstellungen eingetragen werden.

Die neue Sprechanlage ist nun angelegt und kann konfiguriert werden.

Konfiguration

Wurde Deine Sprechanlage automatisch im Netzwerk gefunden und hinzugefügt musst Du die IP Adresse in den Einstellungen nicht mehr angeben.

Deine Sprechanlage wird sofort nach dem Anlegen vom System konfiguriert und startet von selbst neu. Es kann 1-2 Minuten dauern, bis der Vorgang abgeschlossen wurde und die Sprechanlage wieder verbunden ist.

Wurde die Sprechanlage manuell von Dir angelegt, musst Du in die Einstellungen gehen und die IP Adresse eintragen. Nutzername und Passwort sind bereits ausgefüllt, können aber jederzeit geändert werden, falls Du diese in der Türsprechanlage angepasst hast.

Wenn die Sprechanlage manuell hinzugefügt wurde, wird sie nach dem Eintragen nicht automatisch konfiguriert und startet daher nicht von selbst neu. Dadurch kannst Du auch bereits konfigurierte Sprechanlagen in das System einfügen, ohne das die Einstellungen erneut übertragen werden müssen.

Wenn Du eine neue Sprechanlage manuell hinzufügst, musst Du daher nach dem Eintragen der IP Adresse in den Abschnitt "Erweiterte Parameter" navigieren und den Punkt "Sprechanlage Konfiguration zurücksetzen". Nach dem anschliessenden Neustart der Türsprechanlage ist diese betriebsbereit.

Es ist wichtig, dass die Konfiguration der Sprechanlage durchgeführt wird, da erweiterte Funktionen wie die Erkennung der Klingel- und Licht-Tasten sonst nicht funktionieren.

If you want to be able to use the built in microphone and speaker of your intercom to talk to visitors, we recommended to download and use the following apps:

iOS - https://itunes.apple.com/at/app/mobotix/id527836206?mt=8

Android - https://play.google.com/store/apps/details?id=org.abionix.axviewer&hl=de

Bedienung

Wurde die Verbindung mit der Sprechanlage erfolgreich hergestellt, wird im OperatorPanel das aktuelle Videobild angezeigt.

Über das Pfeilsymbol im Bild kann die Videoübertragung vergrößert dargestellt werden.

Wurde die Sprechanlage manuell hinzugefügt und die IP-Adresse noch nicht eingetragen, werden anstelle der Videoübertragung die entsprechenden Eingabefelder angezeigt.

Weiters kann die Klingeltaste der Türsprechanlage kann mit einer Tür verknüpft werden. Dazu in der App „Tür“ eine passende Tür auswählen und in den Einstellungen die Sprechanlage hinzufügen. Wird die Klingeltaste betätigt, wird eine Benachrichtigung mit dem aktuellen Videobild angezeigt und eine Aufnahme des Kamerabilds gespeichert. Ist ein Türöffner vorhanden, kann dieser direkt über das angezeigte Popup bedient werden.

Die Klingel- und Lichttaste der Sprechanlage können außerdem als Auslöser für Szenen verwendet werden.

Das ObjectPanel der Sprechanlage kann über das Kontextmenü vergrößert werden. Dieses wird durch längeres Drücken bzw. Klicken auf das Element geöffnet. In der vergrößerten Ansicht wird ebenfalls das Kamerabild angezeigt.

Die Sprechanlage kann außerdem auf dem Startbildschirm platziert werden, damit das Kamerabild dort direkt sichtbar ist.

Szenen

Die Sprechanlage bietet folgende Auslöser für Szenen (wenn ...):
- Klingeltaster gedrückt: Die Klingeltaste an der Außenstelle wurde betätigt
- Lichttaste gedrückt: Die Lichttaste an der Außenstelle wurde betätigt
- Zugang gewährt: Der Zugang über Zutrittskarte oder Code der Tastenfeld -Erweiterung wurde gewährt
- Zugang verweigert: Der Zugang über Zutrittskarte oder Code der Tastenfeld -Erweiterung wurde verweigert

Fehlersuche

Bei Problemen mit der Sprechverbindung sollten die folgenden Punkte überprüft werden:

1. Netzwerkeinstellungen der Sprechanlage überprüfen
Zunächst unter „Einstellungen“ > „Netzwerk“ einen Verbindungstest durchführen. Die URL „www.google.at“ sollte zu 100 % erreichbar sein. Dadurch wird sichergestellt, dass der Controller über eine korrekte IP-Konfiguration verfügt und die Namensauflösung im Internet funktioniert. Schlägt der Verbindungstest fehl, müssen die Netzwerkeinstellungen überprüft werden. Als DNS-Server kann alternativ der öffentlich verfügbare Google-DNS mit der IP-Adresse 8.8.8.8 verwendet werden.
Anschließend überprüfen, ob die Einstellungen für Subnetzmaske, Standardgateway und DNS-Server auch in der Sprechanlage entsprechend konfiguriert sind (siehe nachfolgende Screenshots).

2. Port-Einstellungen des Internet-Routers überprüfen
Bei manchen Routern sind zusätzliche Einstellungen für Port-Triggering, Port-Forwarding oder virtuelle Server erforderlich. Je nach Router können sich diese Bezeichnungen auf ähnliche Funktionen beziehen. Im entsprechenden Bereich folgende Regeln konfigurieren:

  1. Regel: Name „SIP“, Eingangsport 5060, Ausgangsport 5060 (TCP und UDP)
  2. Regel: Name „SIP_RTP“, Eingangsports 7000-9900, Ausgangsports 7000-9900 (TCP und UDP)

Die Regeln dürfen nur für die IP-Adresse der Sprechanlage gelten (siehe nachfolgende Screenshots).

3. SIP-ALG am Internet-Router deaktivieren
Verfügt der Router über die Einstellung SIP-ALG (Application Layer Gateway), muss diese deaktiviert werden. Die Einstellung ist häufig im Bereich „Sicherheit“ zu finden (siehe nachfolgende Screenshots).

Bei Problemen mit der Erkennung der Klingel- oder Lichttaste der Sprechanlage sollten folgende Punkte überprüft werden.

Damit die Betätigung der Tasten der Sprechanlage im Smart Building Automation System erkannt wird, muss die Sprechanlage zunächst in das System eingebunden werden. Die erforderliche Konfiguration erfolgt automatisch im Hintergrund, sobald die vom System gefundene Sprechanlage hinzugefügt wird.

Wird die Sprechanlage mit einem Tastenfeld verwendet, muss im SettingsPanel unter „Erweiterte Parameter“ die Funktion „Sprechanlage mit Tastenfeld Konfiguration zurücksetzen“ ausgeführt werden. Dies ist sowohl bei einer bestehenden als auch bei einer manuell hinzugefügten Sprechanlage möglich.

Für die Erkennung der beiden Tasten sind keine weiteren Einstellungen erforderlich. Wird die IP-Adresse der Smart Building Automation Engine später geändert, muss die Sprechanlage über das SettingsPanel erneut zurückgesetzt werden.

Überprüfung der Konfiguration

Im SettingsPanel der Kamera können unter „Erweiterte Parameter“ sowohl die Klingel- als auch die Lichttaste überprüft werden. Ist die Konfiguration der Mobotix Sprechanlage korrekt, werden die zugehörigen Events ausgelöst und die entsprechenden Anzeigen im ObjectPanel aktiviert.

Ist dies nicht der Fall, können folgende Einstellungen im Webinterface der Sprechanlage überprüft werden:

1 - Im Admin Menü zu „Profile für Netzwerkmeldungen“ navigieren.

2 - Hier müssen Einträge für „Doorbell“ und „LightSwitch“ vorhanden sein. Jeder Eintrag enthält eine Zieladresse, die mit der IP-Adresse der Smart Building Automation Engine übereinstimmen muss, sowie den vorgegebenen Port „4500“. Im Bereich „Datenprotokoll“ befindet sich außerdem ein Eintrag für den „CGI“-Pfad, der den Systemnamen der Sprechanlage im Smart Building Automation System enthält. Dieser kann im SettingsPanel überprüft werden und muss mit dem hier eingetragenen Systemnamen übereinstimmen.

3 - Im Setup Menü zu „Ereignisübersicht“ navigieren.

4 - Im Bereich „Signalereignisse“ muss jeweils ein Eintrag für die Klingel- und die Lichttaste vorhanden sein. Darauf achten, dass diese nicht auf „Inaktiv“ gesetzt sind.

5 - Im Setup Menü zu „Aktionsgruppen-Übersicht“ navigieren.

6 - Hier müssen ebenfalls Einträge für die Klingel- und die Lichttaste vorhanden sein. Unter „Bearbeiten“ werden im Bereich „Ereignisauswahl“ alle Signale angezeigt, die als Auslöser verwendet werden können. Für die Klingeltaste muss „CameraBellButton“ und für die Lichttaste „CameraLightButton“ ausgewählt sein, passend zu den Signalen aus Punkt 4. Unter „Aktionen“ muss die zugehörige Netzwerkmeldung aus Punkt 2 eingetragen sein.

Die Sprechanlage kann direkt über die Tasten am Gerät zurückgesetzt werden.

T26/S26:
Die Türstation kurz von der Stromversorgung trennen (z. B. Netzwerkstecker abziehen) und anschließend wieder mit Strom versorgen. Etwa 5-10 Sekunden nach dem Herstellen der Spannungsversorgung leuchtet die rote LED für 10 Sekunden. Während dieser Zeit kurz die Lichttaste drücken. Die LED blinkt einmal und wiederholt dieses Blinksignal nach einer Pause von einer Sekunde. Anschließend die Lichttaste länger als 2 Sekunden gedrückt halten. Die Kamera bestätigt die Auswahl durch 3 Sekunden schnelles Blinken und nach 20 Sekunden durch einen Klingelton. Danach startet die Autokonfiguration und die Netzwerkdaten werden angesagt (z. B. IP-Adresse).

T25 (älteres Modell):
Die Türstation kurz von der Stromversorgung trennen (z. B. Netzwerkstecker abziehen) und anschließend wieder mit Strom versorgen. Sobald die Licht- und Klingeltaste am Kameramodul weiß leuchten, die Klingeltaste gedrückt halten, bis beide Tasten kurz blinken. Danach startet die Autokonfiguration und die Netzwerkdaten werden angesagt (z. B. IP-Adresse).

Tastenfeld

Die Türsprechanlage kann um ein Tastenfeld erweitert werden, das den Zutritt sowohl über Zugangscodes als auch über RFID-Karten ermöglicht.

Einführung

Im Folgenden werden die erforderlichen Schritte beschrieben, um eine Mobotix Türsprechanlage (T25) um ein Tastenfeld zu erweitern und für die Einbindung in das Smart Building Automation System vorzubereiten.

Die erforderlichen Schritte gliedern sich in folgende Punkte:

  • Anschluss und Verkabelung
  • Reset der Mobotix (T25) Anlage
  • Erstkonfiguration des Tastenfelds
  • Einrichtung im Smart Building Automation System

https://cdn.competec.ch/documents/2/9/293364/Schnellinstallation_T25_DE.pdf

Reset der Mobotix (T25) Anlage
  • Stromversorgung herstellen und warten, bis die Tasten der Mobotix Kamera leuchten.
  • Die Klingeltaste gedrückt halten, bis beide Tasten kurz blinken.
  • Die Kamera startet neu und gibt die IP-Adresse per Sprachausgabe aus. Die IP-Adresse für die spätere Konfiguration notieren.
Erstkonfiguration des Tastenfelds

Nach Abschluss des Resets der Mobotix Türsprechanlage und der Ausgabe der aktuellen IP-Adresse kann das Tastenfeld konfiguriert werden:

  • Das Keypad blinkt weiß, die ESC-Taste rot und die OK-Taste blau.
  • Gewünschten Super-PIN (8-16 Stellen) eingeben und mit OK bestätigen.
  • Super-PIN erneut eingeben und nochmals mit OK bestätigen.
  • Nach erfolgreicher zweimaliger Eingabe des Super-PIN leuchtet das Keypad kreisförmig weiß und wechselt in den RFID-Einlernmodus.
  • Im Lieferumfang des Keypads befinden sich mehrere RFID-Karten: eine Admin-Karte (rot) sowie mehrere User-Karten (blau).
  • Die Admin-Karte (rot) ca. 5 Sekunden vor das Tastenfeld halten, bis kein Signalton mehr ertönt. Wurde die Admin-Karte erfolgreich eingelernt, leuchtet das Tastenfeld zur Bestätigung kurzzeitig kreisförmig auf (Tasten 2, 4, 6, 7, 9, 0).
  • Anschließend leuchten alle Tasten weiß, die ESC-Taste und die OK-Taste blau. Nun können User-Karten eingelernt werden. Dazu eine User-Karte vor das Tastenfeld halten und warten, bis die Bestätigung in Form des Kreises erscheint. Diesen Schritt für alle gewünschten User-Karten wiederholen.
  • Der Einlernmodus für User-Karten endet nach 2 Minuten automatisch. Alternativ kann der Vorgang durch Drücken der ESC-Taste beendet werden.

Achtung: Der eingegebene Super-PIN überschreibt das Factory Passwort der Türsprechanlage („meinsm“). Nach der Einrichtung des Tastenfelds muss daher der Super-PIN als Passwort für die Anmeldung am Interface der Mobotix verwendet werden.

Zugangscodes einrichten

https://www.youtube.com/watch?v=BqQbM3qUbZM

Nach Abschluss der Erstkonfiguration können die eingelernten RFID-Karten für den Zutritt verwendet werden. Um den einzelnen Karten Zugangscodes (4-16 Ziffern; nur 0 ist nicht zulässig) zuzuweisen, sind folgende Schritte erforderlich:

  • OK-Taste gedrückt halten, bis das Tastenfeld zwei Bestätigungstöne ausgibt. Die OK-Taste blinkt anschließend blau.
  • Admin-Karte vor das Tastenfeld halten, bis ein doppelter Bestätigungston ertönt. Die OK-Taste leuchtet anschließend konstant blau.
  • Schlüssel-Taste drücken. Die Schlüssel-Taste leuchtet anschließend konstant blau.
  • OK-Taste gedrückt halten, bis der zweite Bestätigungston ertönt. Die Schlüssel-Taste und die OK-Taste leuchten anschließend konstant blau.
  • Die Nummer der Karte auswählen, für die ein Zugangscode eingerichtet werden soll. Die Nummer ergibt sich aus der Reihenfolge, in der die Karten eingelernt wurden. „1“ entspricht somit der zuerst eingelernten Karte.
  • Die Nummer der gewünschten Karte eingeben und mit der OK-Taste bestätigen.
  • Gewünschten Zugangscode eingeben und mit der Schlüssel-Taste bestätigen.
  • Zugangscode erneut eingeben und nochmals mit der Schlüssel-Taste bestätigen.
  • Das Tastenfeld bestätigt die Eingabe mit einem Bestätigungston und einem ringförmigen Aufleuchten der Tasten.
Einrichtung im Smart Building Automation System

Um die Mobotix Türsprechanlage mit dem Mobotix Keypad in das System einzubinden, muss eine neue Sprechanlage hinzugefügt werden. Da die Zugangsdaten der Türsprechanlage durch die Einrichtung des Tastenfelds nicht mehr dem Auslieferungszustand entsprechen, muss die Einbindung manuell erfolgen.

  • Zu „Alle Apps“ - „Sprechanlage“ navigieren.
  • „Sprechanlage hinzufügen“ auswählen.
  • Die Sprechanlage sollte automatisch mit der entsprechenden IP-Adresse gefunden werden. Diese für den nächsten Schritt notieren. Sie sollte mit der IP-Adresse übereinstimmen, die beim Reset der Mobotix Sprechanlage ausgegeben wurde.
  • „Manuell“ auswählen.
  • Die zuvor notierte IP-Adresse eingeben. Der Benutzername lautet „admin“, das Passwort entspricht dem am Mobotix Keypad eingerichteten Super-PIN.
  • Sind die eingegebenen Daten korrekt, wird das Bild der Sprechanlage angezeigt.
  • Zum ParameterPanel navigieren, „Erweiterte Parameter“ öffnen und „Sprechanlage mit Tastenfeld Konfiguration zurücksetzen“ auswählen.

Sonos

The app “Sonos” lets you integrate your Sonos loudspeakers into your system.

The Sonos app is located under “all apps” – “Sonos”.

Erstellen

Durch Klick auf „Anmelden“ wird ein Wizard gestartet.

Falls der externe Zugriff nicht aktiviert ist, kann er im angezeigten Wizard durch einen Klick auf Externen Zugriff aktivieren aktiviert werden. Dies ist für den nächsten Schritt erforderlich.

Ist der externe Zugriff bereits aktiviert oder wurde er aktiviert, folgt durch einen Klick auf Verbinden die Weiterleitung zum Sonos-Portal . Sollte der externe Zugriff nur für die Anmeldung aktiviert worden sein, kann er nach der Anmeldung wieder deaktiviert werden.

Danach erscheinen die verknüpften Lautsprecher. Diese können auch unter „Alle Apps“ > „Sonos“ gefunden werden.

ACHTUNG! Zum Verbinden mit Sonos muss der externe Zugriff aktiviert sein („Einstellungen“ >(„Externer Zugriff“). Dieser wird nur einmalig während der Anmeldung benötigt und kann danach gegebenenfalls wieder deaktiviert werden.

Operation

Before Sonos speakers can be integrated into the Smart Building Automation system, they must first be set up using the official Sonos software available here.

Open the Sonos software and start "Sonos setup". Select "Next" and then "Set up new system". Select how the speakers should be connected and follow the remaining setup steps.

Once the setup is complete, the Sonos speakers can be integrated into the Smart Building Automation system. To do this, select "Add new Sonos" in the "Sonos" app. A window opens and displays all available Sonos speakers. Select the Sonos speaker to be added.

Playback can be started or paused using the play and pause symbols in the ObjectPanel or OperatorPanel. The volume can be adjusted using the "+" and "-" buttons in the ParameterPanel or via the slider.

"Favourites" displays the programs and music stored as favourites in Sonos. To add programs or music to the favourites, use the official Sonos software.

A program or music title can also be stored as a favourite using the heart symbol on the right-hand side of the corresponding entry in the OperatorPanel.

Linking

You can use the Sonos with a scene. You have several possibilities.

The “IF” can have the following triggers:

Pause
The scene is invoked when the Sonos is paused.

Play
The scene is invoked when the Sonos play button is pressed.

The “THEN” can have the following actions:

Switch off
The Sonos is switched off when the scene is invoked.

Switch on
The Sonos is switched on when the scene is invoked.

Fade-in
The Sonos begins to play with the “start” volume and increase the volume up to the specified target volume. The ramp-up time defines how long this takes.

Fade-out
The Sonos lowers the volume until it is 0. The ramp-down time defines how long this takes.

Play favourite
The programme or title selected as favourite is played when the scene is invoked.

Configuration

The maximum volume can be adjusted in the Sonos parameter panel.

Siemens Sentron

Mit der App „Siemens Sentron“ können Siemens Leistungsmessgeräte der Serie PAC XXXX (Modbus TCP) in das Smart Building Automation System eingebunden werden. Die App ist unter „Alle Apps“ - „Siemens Sentron“ zu finden.

Aufgrund der kompakteren Bauform und einfacheren Integration werden für die Leistungsmessung die Geräte HC-SM300-00 und HC-SM100-00 empfohlen. Die Siemens Sentron Integration wird daher nicht weitergeführt. Bestehende Integrationen funktionieren weiterhin, neue Messgeräte können jedoch nicht mehr hinzugefügt werden.

Socket

The app “sockets” provides an overview of all sockets in your system and allows you to name them and change their state.

The app “sockets” can be found under “all apps” – “sockets”.

You have two possibilities to change the state of a socket. Either you can click on the power symbol on the left in the object panel or you can click on the button “toggle” in the operator panel.

Configuration

The parameter panel lets you give the socket a name and optionally allocate it to a room.

Save output if bus fault
If the socket is currently active and the bus connection to the CPU fails (e.g. the 24V power supply to the module fails), then activating this option will guarantee that the socket remains active even in a fail state. If this option is not activated, then the socket is reset after every bus connection failure.

In safety-critical controllers, it should be carefully examined whether this function should be activated, since this output is kept active if the system fails.

Reserve (hide in visualization)
If you have a socket in your system that you do not user, you can hide this socket in the app “sockets” by activating the option “reserve (hide in visualization) (located in the parameter panel). (To unhide, the socket can be found in the app “hardware”).

Change mode
If you want to change the mode, i.e. convert socket to a digital output, then this can be done by changing the mode in the socket’s parameter panel.

Scenes

The socket can be used for a scene (in as far as it has been named). In the scene’s “if….”, select the socket and one of the following possibilities:

Switch off
The socket is switched off.

Switch on
The socket is switched on.

Switch on for
The socket is switched on for the time you define.

Toggle
The status of the socket is toggled.

Scenes

Scenes provide a simple and powerful way to personalize the Smart Building Automation system and adapt its control to individual requirements. Without any programming – Directly from the app!

Scenes work according to the IF-THEN principle. For example, pressing a button can open all blinds in a room. This allows almost all functions of the Smart Building Automation system to be combined and linked with each other.

Scenes are quick and easy to create.

For more complex requirements, the Smart Building Automation system can be extended with logic.

Scenes can be found under "All Apps" – "Scenes".

Creating Scenes

To create a scene, simply open the app “scenes” and select “create new scene”. Then open the operator panel for this scene. Enter the name and optionally a room. Then you can start with the configuration (described below).

If you want to invoke a scene from the visualization, you can do this via the left-hand area of the object panel or via the operator panel with the button “invoke”. Otherwise the scene is invoked automatically if the condition you selected using the “IF” statement is true.

If

To add a trigger condition, click in the area “IF” on the button “add” and a window will open where you can add a trigger condition.
For example, if you add a button then you have three options:

  • Pressed
  • More press
  • Double press

If you want to invoke a scene only via the app, you do not need a trigger condition.

If you wish to add several “IFs”, the scene can be invoked by each individual trigger condition, independently of each other.

Then

Click on the button “add” in the area “THEN” to select the action you wish to be invoked from the window that opens. For example, you have the possibility to switch lights on or off, to close shading elements or to move them to a specific position, etc.

For example, if you wish to move the blinds to a specific position, then you are offered the opportunity to define the exact position of this blind and the angle of the slats.

Duplizieren

Bereits erstellte Szenen lassen sich auch duplizieren. Klicken Sie dafür lange auf die Szene, welche Sie duplizieren wollen und wählen dann „Duplizieren“ in der Leiste aus, welche am unteren Bildschirmrand erscheint.

Es werden alle Einstellungen der ausgewählten Szene dupliziert, wie z.B. Wenn, Dann, Bedingungen, Icon, Farbe und der Bereich der Szene.

Conditions

If you only want a scene to be invoked under certain conditions (for example only if it is raining), then you can do this using conditions.

To do this, click at the bottom of the overview on “conditions”. Select here the “only invoke if” and then you can select the corresponding value (e.g. under system – house status the value “rain active”.

After adding this value, you can select others. These are combined using AND or OR logic. If several values are combined via an AND, then all must be active (e.g. “rain active” AND “wind active”) for the scene to be invoked. IF several values are combined via an OR, then at least one of these values must be active (e.g. “rain active” OR “wind active” OR “both active”).

You can edit a condition by clicking on the pencil symbol and delete it by clicking on the trash can symbol.

If a scene is locked due to condition, you can see a padlock in the left-hand area of the object panel, which is also displayed in the operator panel.

Verlauf

Im Parameterpanel haben Sie die Möglichkeit, den Verlauf der Szene einzublenden. Hier werden die letzten 50 Aktionen angezeigt.

Der Verlauf beinhaltet folgende Aktionen:

  • Szene wurde ausgelöst
  • Szene wurde aufgrund einer Bedingung nicht ausgelöst
  • Szene wurde aktiviert
  • Szene wurde deaktiviert

Examples

Garden Watering

The following example shows you how to irrigate your garden using a weekly programme and scenes.
You own a garden irrigation system and would like to activate it at defined times. The garden irrigation system is connected to a digital output, i.e. if this output is active, the irrigation system is switched on. If the output is inactive, the irrigation system is switched off.

The first thing you need is a weekly programme. Create the weekly programme in the app “clock” and select “add clock”, then “weekly programme”. Next, name your weekly programme in the operator panel (e.g. garden irrigation).

Now select the day the irrigation system should be active via the “+” button. In the window that opens, define the two times “from “ and “to”. This means the irrigation system should be active between these times (e.g. Monday from 8 am to 10 am). When you have done this, you can see the time until the next switch point at the top of the operator panel.

Once you have entered all the times when you want the irrigation system to be active, you can change to the parameter panel. If you wish the irrigation system to be active outside of the defined times, you can select under “additional trigger” the trigger that you want to also activate the irrigation system (e.g. a switch is pressed). In the item “runtime for additional trigger”, you need to define how long the irrigation system should be active if you activate it via a switch.

Now all you need to do is link the digital output with the weekly programme. You do this via a scene.

Create a scene, select “add” in the IF section and select your weekly programme, then click on “activate”. Select the digital output under “THEN” and select “ON”. Then create another scene and select the weekly programme for “IF” and select “OFF”
Now your garden irrigation system is ready. Make further adjustments to the weekly programme as required.

Sprachausgabe

Im Folgenden wird erklärt, wie eine Sprachausgabe der aktuellen Außentemperatur mit Hilfe von Logik und Szenen erstellen werden kann.

Zuerst muss eine Logik mit einem Text Block erstellt werden. Dieser muss dann wie am Screenshot zu sehen mit statischen Texten und der Außentemperatur, welche z.B. über die Wetterstation oder Netatmo gelesen werden kann, verknüpft werden.

Danach kann eine Szene erstellt und bei „Wenn“ ein beliebiger Auslöser ausgewählt werden, über welchen die Szene ausgelöst werden soll. Z.B. ein doppelter Tastendruck auf einen Taster im Schlafzimmer.

Bei „Dann“ kann dann unter „System“ > „Sprachausgabe“ > „Sprechen“ beim Parameter „Text“, über den Button rechts neben dem Text Feld, den Text des erstellten Text Blocks ausgewählt werden.

Sobald mit „Übernehmen“ bestätigt wurde, wird der Text Block mit der Szene Verknüpft und die Sprachausgabe liefert den dynamischen Text.

Szenen

Erstellte Szenen können Sie auch in andere Szenen im „Dann“ Bereich verwenden und diese so z.B. auslösen oder deaktivieren.

Es stehen folgende Funktionen für Szenen (dann ...) zu Verfügung:
- Aktivieren: Die Szene wird aktiviert (wenn die Szene vorher deaktiviert war)
- Auslösen: Die Szene wird ausgelöst
- Deaktivieren: Die Szene wird deaktiviert und kann damit von keinem Auslöser (Wenn) gestartet werden

Szenengruppen

Über Szenengruppen lassen sich mehrere Szenen gruppieren um die Übersichtlichkeit zu verbessern.

Um eine Szenengruppe zu erstellen klicken Sie auf das Element „Neue Szenengruppe hinzufügen“. Danach öffnet sich ein Panel in dem Sie dieser Gruppe einen Namen (z.B. „Garten“), Farbe und ein Icon zuweist.

Um eine Szene für diese Gruppe zu erstellen, klicken Sie den Button „Gruppe öffnen“ und wählen dort „Neue Szene erstellen“ aus. Danach öffnet sich das Operatorpanel. Hier geben Sie Name und optional auch einen Raum an.
Auch bestehende Szenen können im Parameterpanel einer Szenengruppe nachträglich zugeordnet werden

Switches

A switch can be connected to a light module, blind module or a digital module.
A switch has a pre-defined function for a light or blind module.
Every switch can be simulated in the system for test purposes.

These switches can be found under "all apps" – "switches".

Erstellen

Taster werden automatisch durch die Konfiguration der Funktionsmodule erstellt. Jedoch können auch Universaltaster erstellt werden, wenn z.B. Taster über Modbus oder KNX integriert werden sollen. Mit einem Klick auf „Universaltaster hinzufügen“ wird ein universeller Taster hinzugefügt.

Configuration

Naming
If you have connected your switch to a light or shading module, then the switch is automatically named according to the light or blind. If you wish to give it a different name, then deactivate the option “same name as blind/light” in the parameter panel and give the switch a new name. If you have connected your switch to a digital module, then you must name it yourself.

Reserve
If you have a switch in your system that you don’t use, then you can hide it by deactivating the option “reserve “hide in display” in the app “ switches”. To unhide it, you can find your switch in the app “hardware”.

Mode
If you want to change the mode, i.e. define the switch as a presence detector or a digital input, then you can do this in the parameter panel under “mode”. Not every module can change the mode however, or not all possibilities are available. This means that the light modules’ switch can only be converted to a presence detector. Switches for a blind element cannot be converted. Switches for digital modules have all three modes.

Simulation

If you have linked a switch to a scene and would now like to simulate this scene, then there is no need to go to the switch and press it every time, you can use simulation to create the switch press. Simply activate the option “simulation” in the operator panel to see 3 buttons that you can use to simulate switch presses.

Warning: If you leave the simulation mode activated, the autonomous functions will not work!

Settings

Open the switches settings (“all apps” – “settings” – “switches”) if you want to define the times for a press and double-press. Select the desired values and confirm them by clicking the button “use values for all switches”.

Hold time (long button press)
A switch must be pressed for at least thus time to be recognized as a long button press.

Wait time (double-press)
The gap between two switch presses must be as least as big as the defined wait time to be recognized as a double-press.

If you wish to define different values for a switch that is connected to a blind module, then activate the option “use other values for blinds”.

Scene

You can use the switches for a scene (assuming it as been named). In the scene “if …” just select the switch and decide if you want the scene to be executed after a single, double or long press.

TCP Client

The TCP Client app allows you to communicate with TCP-compatible devices (TCP clients). Among them are devices like beamers, TVs and many more. Additionally, you can use a gateway (TCP to serial port) to send commands to different devices with a serial port.

The TCP Client app is located under “all apps” – “TCP Client”.

Create

To create a new TCP Client, navigate to the app and choose 'add TCP client'.

On every TCP Client, there is a symbol which shows you if there ist a working connection to the desired device. As you have to configure every new TCP Client first, the symbol will display a red X.

Before the TCP Client can communicate, you have to enter a valid IP address in the settings. To do so, open the Parameter panel of your newly created TCP Clients and enter the IP address and the port of the desired device.

If the IP address and port are correct and a successful connection could be established, you will see a green checkmark in the display of the TCP Client after some seconds.

Configuration

The settings of the TCP Client allow you to configure new commands and events, which can be linked in scenes.

IP configuration
The IP address and port of the device for which you want your TCP Client to establish a connection to should be entered here. This settings should be the first configuration you make after creating a new TCP Client. The Operator Panel will then tell you if your connection is working.

Commands
If you want to create a new command, you can do this here by using the 'new command' button. Choose a name and the data which should be send. You can decide between simple text or hex values. Additionally, you can also decide whether you expect a specific answer and choose between text or hex values.

Test command
If you just want to test a command, you can do this here. The result will then be displayed beneath the 'test command' button.

Events
There are some devices, which may frequently send data, without the need for a explicit request (e.g. via a command). For such use cases, every TCP Client has 3 events. For each event, you can set what data you are expecting and their type (text or hex). If an expected event occurs this event will be triggered and can be linked to when creating a Scene.

Operation

The Operator Panel of the TCP Client displays the current status of the client, allows you to send preconfigured commands and shows you a list of recently received data.

State
The current status of the TCP Client will be shown here.In case there are any problems with the connection to the desired device or you haven't entered a correct IP address yet, a red X will be displayed.

Events
Every TCP Client allows you to create 3 events, which are triggered when the conditions meets. You can then link to those events in created scenes (inside the Scene app) and use them as triggers. Configured events will be displayed in this list.

Commands
All commands you have created are listed here. You can trigger or delete each one.

Last received data
This list will display recently received data. You can switch between a 'text' or 'hex' view.

Szenen

Der TCP Client bietet folgende Auslöser für Szenen (wenn ...):
- Ereignis 1 ausgelöst: Das konfigurierte Ereignis 1 wurde ausgelöst
- Ereignis 2 ausgelöst: Das konfigurierte Ereignis 2 wurde ausgelöst
- Ereignis 3 ausgelöst: Das konfigurierte Ereignis 3 wurde ausgelöst
- Erwartete Daten vom Befehl empfangen: Die konfigurierten erwarteten Daten nach Absetzen des Befehls wurden empfangen

Temperature Sensor

You can view all the module channels to which you can connect temperature sensors (e.g. PT1000) in the app “temperature”.

The temperature sensors can be found under “all apps” – “temperature”.

Configuration

With module A1240, you can only set the temperature limits (as described in the item “scene” above). This module can only accept temperature sensors of type PT1000.

If you posses a module of type A1380, you can connect temperature sensors of type PT1000, KTY81-110 and KTY81-210. To ensure that the modules know which sensor has been connected, you must navigate to the parameter panel for this temperature sensor and select the type under “mode”.

Simulation

If you want to know what happens if the temperature rises above or falls below a certain value, then you don’t need to cool or heat the temperature sensor. You can use the option “simulation” in the operator panel. Simply activate the checkbox “simulation on” and enter the desired temperature in the input field that appears. Warning, do not forget to deactivate the simulation when you have finished testing.

Usage

Hier werden Dir einige Beispiele beschrieben wie Du einen Temperatursensor verwenden kannst.

Outside temperature
If you want a temperature sensor in your system to determine the outside temperature, you need to add it using the button “add” in the global settings under the item “outside temperature” and drag it to the first position. (More information in this in the documentation for global settings).

External current value for room climate zone
If you want to use this temperature sensor as an actual value for a room climate zone, then you must set the mode to “external actual value” in the desired room climate zone under “settings” and then connect the temperature sensor with it (more detail in the chapter “room climate”).

Scene
In order to link a temperature sensor with a scene, you must first allocate a name to it. Then you can set an upper and a lower temperature limit in the parameter panel that you can use in the scene for the “if …” statement. You can create a scene for the temperature falling below the lower limit or rising above the upper limit.

Logic
If you are an expert with the app “logic”, you can also use this temperature sensor here by connecting the input of a logic element with the current temperature reading.

Szenen

Die Temperatur App bietet folgende Auslöser für Szenen (wenn ...):
- Obere Grenze überschritten: Das konfigurierte obere Temperaturlimit wurde überschritten
- Untere Grenze unterschritten: Das konfigurierte untere Temperaturlimit wurde unterschritten

Door

The "Door" app allows doors to be created in the Smart Building Automation system and linked to a camera, doorbell button, doorbell, door contact, and door opener contact.

The "Door" app can be found under "All Apps" – "Door".

Configuration

Intercom
Choose a connected intercom. "Camera" and "Bellpush" will automatically be assigned.

Camera
This field lets you select a camera for this door. The camera image is then always displayed on the operator panel.

Bellpush
Use the button “add” to add one or more buttons you wish to use to ring the doorbell.

Doorbell
Select the digital output that is connected with the doorbell.

Door opener
Select the digital output connected to the door opener using the button “add”.

Signal light
If you in a room where it is not possible to hear the doorbell, you can select a light in this room that will flash when someone rings the doorbell

Number of flashes
Define the number of times the signal light is to flash when someone rings the doorbell.

Signal light on time
Defines how long the signal flash is to be.

Door open time
Defines how long the door remains open, if you open it via the app.

Doorbell time
Defines how long the digital output for the doorbell is to remain active.

Melody
If you want a melody to play on your smartphone, or tablet etc. when someone rings the doorbell, then you can choose here between two melodies.

Simulate
You can simulate the doorbell button press using the button “ring” to test whether you have satisfactorily configured all options according to your requirements. This has the same effect as if someone had really pressed the doorbell.

If you want to be able to use the built in microphone and speaker of your intercom to talk to visitors, we recommended to download and use the following apps:

iOS - https://itunes.apple.com/at/app/mobotix/id527836206?mt=8

Android - https://play.google.com/store/apps/details?id=org.abionix.axviewer&hl=de

Operation

If you open the operator panel for your door, then you can see the camera image (if a camera is linked to this door) and a button “open door” that lets you open this door (if a door open contact has been selected).

As soon as someone rings the bell for this door, you will receive a notification and a photo is taken of the moment the bell was rung that you can see when you open the notification.

Benachrichtigung

Wenn Sie die Benachrichtigungen aktiviert haben, öffnet sich auf ihrem Desktop ein Fenster in welchem entweder das Livebild oder das gespeicherte Bild angezeigt, welches beim Klingeln aufgenommen wurde. Was groß angezeigt wird, können Sie wie bereits zuvor beschrieben im Parameter Panel einstellen. In der rechten unteren Ecke wird entweder der Schriftzug „Live“ oder das aufgenommene Bild in Kleinformat angezeigt. Beim Klick auf einer dieser beiden Objekte, wird nun das ausgewählte groß dargestellt und das anderen in der rechten Ecke abgelegt.

Zudem können Sie die Nachricht als gelesen markieren, wodurch diese Benachrichtigung aus dem Nachrichtenordner entfernt wird.

Szenen

Die Tür bietet folgende Auslöser für Szenen (wenn ...):

  • Klingel läutet: Die Klingeltaste wurde betätigt
  • Tür wird geöffnet: Der elektrische Kontakte zum Türöffnen (z.B.: Motorschloss) wurde betätigt

Die Tür bietet folgende Funktionen für Szenen (dann ...):
- Aktuelles Kamerabild speichern: Das aktuelle Kamerabild der zugewiesenen Kamera wird gespeichert
- Öffnen: Der elektrische Kontakt zum Türöffnen (z.B.: Motorschloss) wird aktiviert
- Türklingel aktivieren: Die Türklingel wird aktiviert (wenn diese vorher deaktiviert war)
- Türklingel auslösen: Die konfigurierte Türklingel wird ausgelöst
- Türklingel deaktivieren: Die Türklingel wird deaktiviert

Trending

Mit der App „Trending“ können verschiedene Werte des Smart Building Automation Systems aufgezeichnet und in einem Diagramm dargestellt werden.

Die App „Trending“ ist unter „Alle Apps“ zu finden.

Erstellen

„Um ein neues Trending Panel zu erstellen, navigieren Sie zur App und wählen Sie 'Trending hinzufügen'.“

Konfiguration

In den Einstellungen können Sie konfigurieren welche Werte aufgezeichnet werden sollen, wie lange diese aufgezeichnet werden sollen und wie diese im Diagramm dargestellt werden sollen.

Einstellungen
Diagramm Typ
Der Diagramm Typ entscheidet ob das Diagramm als Flächen- oder Liniendiagramm angezeigt wird.

Werte dauerhaft speichern
Wenn diese Option aktiviert wird werden die aufgezeichneten Werte über den Neustart hinweg gespeichert.

Nur bei Wertänderung aufzeichnen
Wenn diese Option aktiviert ist, wird das Aufzeichnungsintervall ignoriert und nur dann ein Aufzeichnungspunkt erstellt, wenn sich der Wert ändert.

Aufzeichnungsintervall
Das Aufzeichnungsintervall bestimmt in welchen Abständen ein neuer Wert vom Trend aufgezeichnet wird. Gemeinsam mit der Anzahl an Aufzeichnungspunkten ergibt sich der Zeitraum über den aufgezeichnet wird.

Maximale Anzahl an Aufzeichnungspunkten
Die maximale Anzahl an Aufzeichnungspunkten entscheidet wie viele Punkte maximal aufgezeichnet werden können. Wenn diese Anzahl überschritten wird werden ältere Punkte gelöscht. Der Wert kann von 1 - 1.000 eingestellt werden. Gemeinsam mit dem Aufzeichnungsintervall ergibt sich der Zeitraum über den aufgezeichnet wird.

Damit die Einstellungen übernommen werden muss der Button „Einstellungen übernehmen“ betätigt werden.

Variablen
Es können insgesamt 8 Werte ausgewählt werden welche vom Trend aufgezeichnet werden sollen. Durch den Button „hinzufügen“ können neue Werte hinzugefügt werden.

Werte in Diagramm anzeigen
Wenn diese Option aktiviert ist wird der Wert im Diagramm angezeigt.

Interpolation
Wenn diese Option aktiviert ist, werden fehlende Zwischenwerte zwischen den aufgezeichneten Messpunkten berechnet, damit der Verlauf im Diagramm glatter und durchgehend dargestellt wird.

Alias
Wenn diese Option aktiviert ist können Sie einen eigenen Namen für den Wert angeben, welcher dann im Diagramm angezeigt wird.

Farbe
Hier können Sie eine eigene Farbe auswählen, in welcher dann der Wert im Diagramm angezeigt wird.

Bedienung

Die Ansicht der Trending App unterstützt drei verschiedene Größen. Wenn Sie für einige Sekunden die Auswahl auf der Trending App (mit dem Mauszeiger Linksklick oder mit dem Finger gedrückt halten) erscheint am unteren Bildschirmrand ein Panel, bei dem Sie unter anderem die Möglichkeit haben die Größe zu ändern.

In der kleinsten Ansicht wird Ihnen nur der Name und der Raum des Trends angezeigt. Bei Klick auf die Ansicht öffnet sich die Bedienung und die Einstellungen.

In der weiten Ansicht wird Ihnen zusätzlich das Diagramm angezeigt.

In der größten Ansicht haben Sie zusätzlich die Möglichkeit das Diagramm in einer größeren Ansicht zu betrachten indem Sie auf das Pfeil Symbol am rechten oberen Rand klicken.

Durch einen Klick auf den Namen des Trends öffnet sich die erweiterte Bedienung.

In der Bedienung des Trends sehen Sie das Diagramm mit den aufgezeichneten Werten. Zusätzlich können Sie eine größere Ansicht über das Pfeil Symbol in der rechten oberen Ecke öffnen. Im unteren Bereich des Diagramms wird Ihnen die Legende angezeigt, hier können Sie temporär einzelne Werte ausblenden.

Export

Sie können auch Ihre Trenddaten bequem als CSV-Dateien (comma-separated values) exportieren um diese anschließend in einem anderen Programm (z.B.: Excel) weiterzuverarbeiten. Dazu müssen Sie die Checkbox „Werte dauerhaft speichern“ anhaken, danach erscheint im Bedienpanel ein Button welcher den Download der Daten erlaubt.

Das nachfolgende Beispiel soll den Import der Dateien in MS-Excel veranschaulichen. Öffnen Sie dazu zunächst MS-Excel mit einer leeren Arbeitsmappe.

Navigieren Sie auf den Reiter „Daten“ und klicken Sie auf das Feld „Aus Text/CSV“.

Wählen Sie nun die zuvor heruntergeladene Datei aus. Prüfen Sie ob die Felder und deren Typen (Zeit, Datum) korrekt erkannt werden. Sollten die Typen falsch angezeigt werden, so wie in diesem Beispiel das Datum, können Sie über Bearbeiten den Typ jeder Spalte anpassen.

Die Änderung des Datentyps erfolgt durch Klicken auf das Symbol in der Kopfzeile jeder Spalte. Klicken Sie anschließend auf „Schließen&Laden“.

Durch Hinzufügen eines Liniendiagramms können Sie nun sehr einfach eigene Diagramme aus den Rohdaten erstellen.

uLux

The "uLux" app allows the uLux switch to be configured in the Smart Building Automation system.

The "uLux" app is located under "all apps" – "uLux".

Important: To use the uLux switch with the Smart Building Automation system, the required uLux design template must be stored on the switch. All Smart Building Automation uLux switches already contain this template when delivered. Further configuration using the uLux software is therefore not required.

Create

To create a new uLux room, click on the add symbol, after which a search for uLux switches in your network is started. If the switch is not immediately found, you can just restart the search. Once the uLux is found, you just have to select it to add it to your system.

Configuration

After the uLux switch has been found, you only need to add a name, a room and an IP-address.

Settings
Here, you can change the network address of your uLux switch.

If you edit this settings, you will have to press the button 'write configuration' to transfer them to your uLux switch. The switch will then restart and boot up with your new configuration after some seconds.

Operation

The uLux switch works like a room control. This makes it easy to add all elements from a room (lights, blinds, heating, scenes) to it.

Just add a name and room to your uLux switch and once you finish the configuration every element from this room will automatically be displayed on the switch.

If an uLux extension module is connected, your can find all measured values in the 'extension' section. Those values can also be linked in the Logic app.

Szenen

Der u::Lux Schalter bietet folgende Auslöser für Szenen (wenn ...):

  • Bewegung erkannt (Erweiterungsmodul): Am u::Lux wurde eine Bewegung erkannt (Nur mit Erweiterungsmodul möglich).

Vaillant

Die App „Vaillant“ ermöglicht die Integration von Vaillant Wärmeerzeugern in das Smart Building Automation System.

Möglichkeiten durch die Integration:

  1. Einfache Bedienung der Anlage über die Smart Building Automation App. Der Datenaustausch erfolgt ausschließlich über das lokale Netzwerk. Eine Cloud-Anbindung ist nicht erforderlich.

    • Anzeige der Istwerte: aktuelle Raumtemperatur, Brauchwassertemperatur und Außentemperatur
    • Anzeige und Änderung des Betriebsmodus
    • Anpassung der Brauchwassersolltemperatur
  2. Freie Definition gewerkeübergreifender Regeln zur Erhöhung des Wohnkomforts. Beispielsweise kann durch das Aktivieren des Urlaubsstatus der Wärmeerzeuger in die gewünschte Betriebsart versetzt werden.

  3. Maximierung der Energieeffizienz durch den direkten Informationsaustausch zwischen Vaillant Wärmeerzeugern und dem Smart Building Automation System. Die herstellerübergreifende Kommunikation erfolgt über EEBUS. Beispielsweise kann ein elektrischer Energieüberschuss zur Unterstützung der Brauchwassererzeugung genutzt werden.

Voraussetzungen:

  • Vaillant Wärmeerzeuger mit VRC 700/720-Regler und Kommunikationseinheit VR92X (bei Exklusivgeräten im Lieferumfang enthalten oder im Gerät integriert)
  • Schrack Smart Building Automation Controller „iX800“ oder „iX840“ mit den erforderlichen Systemmodulen
  • Vaillant Kommunikationseinheit VR9XX (LAN oder WLAN) und Smart Building Automation Controller (LAN) im selben lokalen Netzwerk
  • Freigabe der EEBUS-Verbindung in beiden Apps

Die App „Vaillant“ ist unter „Alle Apps“ – „Vaillant“ zu finden.

Erstellen

Um einen Vaillant Wärmeerzeuger hinzuzufügen, muss das Smart Building Automation System zunächst in der Vaillant myVaillant App auf einem iOS- oder Android-Gerät als vertrauenswürdiges Gerät hinzugefügt werden.

Dazu zuerst unter „Einstellungen“ – „EEBus“ den EEBUS-Dienst im Smart Building Automation System starten. Weitere Informationen: EEBus App

Anschließend kann das Smart Building Automation System in der myVaillant App unter „Einstellungen“ – „Netzwerkeinstellungen“ – „EEBus“ als vertrautes Gerät hinzugefügt werden.

Danach muss auch der Vaillant Wärmeerzeuger unter „Einstellungen“ – „EEBus“ im Smart Building Automation System als vertrautes Gerät hinzugefügt werden. Weitere Informationen: EEBus App

Nach erfolgreicher Verbindung wird unter „Alle Apps“ – „Vaillant“ automatisch eine Vaillant Instanz erstellt.

Bedienung

Nach erfolgreichem Verbinden wird der Wärmeerzeuger unter „Alle Apps“ - „Vaillant“ angezeigt.

Das Operator Panel zeigt den Status der einzelnen Zonen, den Status des Warmwassers und die aktuelle Außentemperatur an.

Zudem kann im Operator Panel der Modus der Zone geändert, sowie der Sollwert für „Tag“ und „Nacht“ angepasst werden.
Vaillant Wärmeerzeuger mit VRC 700-Regler haben folgende Modi, zwischen denen gewechselt werden kann:

  • Aus
  • Auto
  • Tag
  • Nacht

Auch bei einem VCR 720-Regler, kann der Modus der Zone geändert, jedoch kann der Sollwert nur für den Modus „Manuell“ geändert werden
Vaillant Wärmeerzeuger mit VRC 720-Regler haben folgende Modi, zwischen denen gewechselt werden kann:

  • Aus
  • Zeitgesteuert (Gleich wie „Auto“ bei VCR 700)
  • Manuell

Außerdem kann die Solltemperatur des Warmwassers und der Modus zwischen „Aus“, „Auto“ und „Ein“ angepasst werden.

Konfiguration

Im Parameter Panel kann der Name und Raum des Wärmeerzeugers vergeben werden.

Unter „Status“ ist der aktuelle Verbindungsstatus des Gerätes ersichtlich.

Unter „Einstellungen“ kann ausgewählt werden, welcher Wert für die Anzeige im Object Panel verwendet werden soll. Dabei können Sie zwischen der Warmwassertemperatur und den vorhandenen Heizzonen wählen.

Szenen

Die Vaillant App bietet folgende Funktionen für Szenen (dann ...):

Vaillant:

  • auf Auto Betrieb umschalten: Setzt den Betrieb des Warmwassers auf Auto
  • Ausschalten: Schaltet die Regelung des Warmwassers aus
  • Einschalten: Schaltet die Regelung des Warmwassers ein
  • Solltemperatur für Warmwasser setzen: Setzt die Solltemperatur für das Warmwasser

Zonen:
VRC 700:

  • auf Auto Betrieb umschalten: Setzt den Betrieb der Zone auf Auto
  • auf Nacht Betrieb umschalten: Setzt den Betrieb der Zone auf Nacht
  • auf Tag Betrieb umschalten: Setzt den Betrieb der Zone auf Tag
  • Ausschalten: Schaltet die Zone aus
  • Solltemperatur für Nacht setzen: Setzt die Solltemperatur für den Nachtbetrieb der Zone
  • Solltemperatur für Tag setzen: Setzt die Solltemperatur für den Tagbetrieb der Zone

VRC 720:

  • auf Modus Manuell umschalten: Setzt den Modus der Zone auf Manuell
  • auf Modus Zeitgesteuert umschalten: Setzt den Modus der Zone auf Zeitgesteuert
  • Ausschalten: Schaltet die Zone aus
  • Wunschtemperatur setzten: Setzt die Solltemperatur für die Zone

Logik

Die Vaillant App bietet folgende Möglichkeiten für die Verwendung in Logiken:

Vaillant:

  • Solltemperatur Warmwasser: Die Solltemperatur des Warmwassers (lesen & schreiben)
  • Außentemperatur: Die Außentemperatur (lesen)

Zonen:
VRC 700:

  • Solltemperatur Tag: Die Solltemperatur für den Tag (lesen & schreiben)
  • Solltemperatur Nacht: Die Solltemperatur für die Nacht (lesen & schreiben)

VRC 720:

  • Wunschtemperatur setzen: Die Solltemperatur (lesen & schreiben)

Velux

Mit der App „Velux“ können Velux Fenster- und Beschattungselemente über das Smart Building Automation System gesteuert werden. Die im Velux KLF200 Interface definierten Programme können in wenigen Schritten in das Smart Building Automation System importiert und anschließend verwendet werden.

Die App „Velux“ ist unter „Einstellungen“ – „Velux“ zu finden.

Erstellen

Für die Integration von Velux Geräten müssen diese mit einem Velux KLF200 Interface verknüpft sein.

Das KLF200 Interface muss per LAN mit demselben Netzwerk wie das Smart Building Automation System verbunden sein.

Für das KLF200 Interface sollte eine freie statische IP-Adresse vergeben werden.

Das KLF200 Interface muss mindestens über die Firmware-Version 0.2.0.0.71.0 verfügen. Die Firmware kann unter folgender Adresse heruntergeladen werden: https://updates2.velux.com/

Um die Netzwerkeinstellungen des KLF200 Interface zu konfigurieren, über WLAN mit dem Interface verbinden und im Browser die Adresse 192.168.0.1 aufrufen. Das Passwort für die Anmeldung befindet sich auf der Rückseite des Gerätes.

Nach erfolgreicher Anmeldung sind die Netzwerkeinstellungen unter „LAN“ zu finden.

Hier sollte eine noch freie statische IP-Adresse vergeben werden.

Unter dem Reiter „Programme“ können die Szenen des KLF200 Interface verwaltet werden. Diese können anschließend im Smart Building Automation System verknüpft werden.

Nach der Inbetriebnahme kann das KLF200 Interface über „Gateway hinzufügen“ in das Smart Building Automation System integriert werden.

Im nächsten Schritt müssen die IP-Adresse des KLF200 Interface und das Passwort im ParameterPanel eingegeben werden.

Das Passwort befindet sich auf der Rückseite des Gerätes. Für die Konfiguration im Smart Building Automation System muss das unter der SSID angeführte Passwort verwendet werden, nicht das Passwort für den Web-Login.

Nach erfolgreicher Verbindung zum KLF200 Interface wird der Verbindungsstatus im OperatorPanel angezeigt.

Über „Szenen aktualisieren“ werden alle am Gateway eingelernten Programme in das Smart Building Automation System importiert und stehen anschließend zur Verfügung.

Bedienung

Durch Klick auf den linken Bereich im Object Panel oder mittels Klick auf „Szenen anzeigen“ im Operator Panel werden alle Szenen angezeigt.

Jede Szene kann durch Klick auf den Play-Button im linken Bereich des Object Panel oder im Operator Panel mittels Klick auf „Szene ausführen“ ausgeführt werden.

Zusätzlich kann jede Szene unter „dann ...“ als Aktion in einer anderen Szene verwendet werden.

Nachdem eine Szene gestartet wurde, kann diese durch Klick auf den Pause-Button wieder gestoppt werden.

Achtung: Es kann immer nur eine Szene gleichzeitig ausgeführt werden. Falls mehrere Szenen gestartet werden, werden diese hintereinander ausgeführt.

Im Parameter Panel jeder Szene kann die Ausführungsgeschwindigkeit der Szene eingestellt werden.

Dabei ist zu beachten, dass nicht alle Geräte jede Geschwindigkeit unterstützen.

WakeOnLAN

Die Wake On Lan App ermöglicht Ihnen das Aktivieren/Starten verschiedener Netzwerkgeräte (TV-Geräte, Beamer, PCs, ...) welche sich in einem Standby-Zustand befinden.

Konfiguration

Geräte welche die Wake On Lan (WOL) Funktion unterstützen erwarten den Empfang der eigenen MAC-Adresse in einer speziellen Form. Aus diesem Grund muss zur Konfiguration nur die MAC-Adresse des gewünschten Gerätes eingestellt werden. Die eingegebene MAC-Adresse wird dabei validiert, die folgenden Formate werden unterstützt:

  • AA:BB:CC:DD:EE:FF
  • AA-BB-CC-DD-EE-FF
  • AA.BB.CC.DD.EE.FF

Die Wake On Lan Funktion muss bei einigen Geräten erst aktiviert werden. Als Beispiel wird das Aktivieren der Funktion auf einem Windows-PC erklärt. Unter Systemsteuerung -> Netzwerk und Internet -> Netzwerkverbindungen -> Adapter auswählen -> Eigenschaften -> Konfigurieren... -> Erweitert -> Wake on Magic Packet -> ENABLED.
Das Aktivieren der Funktion kann abhängig vom Gerät und Schnittstelle anders funktionieren, wird aber meistens von den Herstellern dokumentiert.

Bedienung

Durch drücken des „Wake Up!“ Buttons wird die Wake On Lan Funktion für das konfigurierte Gerät (MAC-Adresse) ausgeführt.

Szenen

Die WakeOnLAN App bietet folgende Funktionen für Szenen (dann ...):

  • WakeUp: Löst den Aufwachvorgang des konfigurierten Endgerätes aus

Heatpump

Erstellen

Die Anbindung und Steuerung einer Wärmepumpe im Smart Building Automation System erfolgt über digitale Eingänge sowie digitale oder analoge Ausgänge, abhängig davon, welche Schnittstellen die Wärmepumpe unterstützt.

Nachdem die Wärmepumpe an die entsprechenden Ein- und Ausgänge angeschlossen wurde, muss sie im Smart Building Automation System angelegt werden.

Dazu „Wärmepumpe hinzufügen“ auswählen.

Nun wird eine neue Wärmepumpe erstellt und kann konfiguriert werden.

Konfiguration

Nachdem eine neue Wärmepumpe im Smart Building Automation System angelegt wurde, kann dieser zunächst ein Name zugewiesen und ein Raum zugeordnet werden.

In den Einstellungen kann außerdem die Funktion „Betriebsmodus für Raumklima übernehmen“ aktiviert werden. Ist diese Funktion aktiv, wird bei einer Änderung des Betriebsmodus der Wärmepumpe (Heizen/Kühlen) auch der Modus des Raumklimas entsprechend angepasst.

Um die angebundene Wärmepumpe zu steuern oder deren aktuellen Status abzufragen, müssen die entsprechenden Ein- und Ausgänge ausgewählt werden, über die diese mit dem System verbunden ist.

Über die digitalen Eingänge kann der Status folgender Werte abgefragt werden:

Ein/Aus
Zeigt den aktuellen Betriebszustand an.

Modus (Heizen/Kühlen)
Zeigt den aktuellen Betriebsmodus der Wärmepumpe an.

Störung
Zeigt eine Störung der Wärmepumpe an.

Da nicht jede Wärmepumpe die digitalen Signale gleich handhabt, kann für jeden Eingang festgelegt werden, wie das jeweilige Signal interpretiert werden soll.

Die Verwendung der digitalen Eingänge ist für den Betrieb der Wärmepumpen-App nicht zwingend erforderlich. Sind nicht alle oder keine der digitalen Eingänge konfiguriert, werden für die angezeigten Werte (Modus, Status) die aktuellen Zustände der digitalen Ausgänge verwendet.

Über die digitalen Ausgänge können folgende Werte gesteuert werden:

Ein/Aus
Steuert den Betriebszustand der Wärmepumpe. Dieser Ausgang ist zwingend erforderlich, um die Wärmepumpe in Betrieb zu nehmen und die weiteren Bedienelemente zu aktivieren..

Modus (Heizen/Kühlen)
Steuert den Betriebsmodus der Wärmepumpe.

Auch für die Ausgänge kann festgelegt werden, wie die Signale interpretiert werden sollen.

Steuerung der Betriebsstufe
Für die Steuerung der Betriebsstufe kann zwischen einem analogen und digitalen Ausgang gewählt werden. Bei analoger Steuerung wird nur ein Ausgang benötigt, über den die Betriebsstufe in 10 Stufen geregelt werden kann.

Bei der Verwendung digitaler Ausgänge werden drei einzelne digitale Ausgänge benötigt, über die die Wärmepumpe in drei Stufen geregelt werden kann.

Operation

Szenen

Die Wärmepumpe bietet folgende Auslöser für Szenen (wenn ...):

  • Betrieb Aus: Die Wärmepumpe wurde ausgeschaltet
  • Betrieb Ein: Die Wärmepumpe wurde eingeschaltet
  • Modus Heizen: Der Modus der Wärmepumpe wurde auf Heizen gestellt
  • Modus Kühlen: Der Modus der Wärmepumpe wurde auf Kühlen gestellt
  • Störung erkannt: Eine Störung der Wärmepumpe wurde gemeldet

Die Wärmepumpe bietet folgende Funktionen für Szenen (dann ...):

  • Ausschalten: Die Wärmepumpe wird ausgeschaltet
  • Betriebsstufe setzen: Eine beliebige Betriebsstufe kann für das Gerät gesetzt werden
  • Einschalten: Die Wärmepumpe wird eingeschaltet
  • Heizen: Der Modus Heizen wird aktiviert
  • Kühlen: Der Modus Kühlen wird aktiviert

Weather Station

The Schrack Smart Building Automation weather station is a simple way to receive local weather data and use it in your Schrack Smart Building Automation system.

The app "weather station" is located under "all apps" – "weather station".

In order to use this weather station, open the global settings, found in "all apps" – "settings" – "global settings" and drag the weather station to the first position for wind, rain, outside temperature and daylight (it is also possible to only use the weather station for wind).

Create

The following steps are required to set up the Schrack Smart Building Automation weather station.

Mounting
Mount the weather station according to the documentation. Pay attention to the specified orientation and required mounting distances.

Connecting
Connect the 2-wire bus cable of the weather station to a Schrack Smart Building Automation controller, such as the "iX800" or "iX840".
Ensure the correct polarity of connections A and B. J-Y(ST)Y 2 × 2 × 0.8 is recommended as the cable.
The weather station must be connected to the rightmost RS485 interface of the controller in order to be detected by the system.

Power supply
Supply the weather station with power according to the documentation.

Add
Add a new weather station in the app. If installed correctly, a connection is established automatically. The weather data is then updated once per second.

Note: Only one weather station can be operated per Schrack Smart Building Automation controller.

Note: The weather station must be connected to the rightmost RS485 interface of the controller.

Configuration

Wind alarm settings
The wind alarm settings let you define a wind speed above which an alarm is triggered. You can also define hysteresis so that the wind alarm does not trigger and end continuously should the wind speed oscillate around the alarm value. If you want that the wind alarm is active only after a certain time, then you need to enter a delay. This means that this time must be longer than the time set for “wind speed alarm”, so that a wind alarm is triggered.

Dawn/dusk settings
These settings let you define the light levels when dusk/dawn is active and inactive. Hysteresis and delay have the same functions as described previously.

Operation

In the Operatorpanel of the Weather Station, you will find several statistics and charts, which provide you with an insight on the measured values.

Szenen

Die Wetterstation bietet folgende Auslöser für Szenen (wenn ...):

  • Aufgehört zu regnen: Das Ende des Niederschlags wurde erkannt
  • Außentemperatur Max-Limit überschritten: Das konfigurierte Max-Limit der Außentemperatur wurde überschritten
  • Außentemperatur Min-Limit unterschritten: Das konfigurierte Min-Limit der Außentemperatur wurde unterschritten
  • Regen (Niederschlag) erkannt: Der Beginn des Niederschlags wurde erkannt
  • Sonnenaufgang: Der Sonnenaufgang wurde erkannt
  • Sonneneinstrahlung-Ost Max-Limit überschritten: Das konfigurierte Sonnenstrahlung Max-Limit im Osten wurde überschritten
  • Sonneneinstrahlung-Ost Min-Limit unterschritten: Das konfigurierte Sonnenstrahlung Min-Limit im Osten wurde unterschritten
  • Sonneneinstrahlung-Süd Max-Limit überschritten: Das konfigurierte Sonnenstrahlung Max-Limit im Süden wurde überschritten
  • Sonneneinstrahlung-Süd Min-Limit unterschritten: Das konfigurierte Sonnenstrahlung Min-Limit im Süden wurde unterschritten
  • Sonneneinstrahlung-West Max-Limit überschritten: Das konfigurierte Sonnenstrahlung Max-Limit im Westen wurde überschritten
  • Sonneneinstrahlung-West Min-Limit unterschritten: Das konfigurierte Sonnenstrahlung Min-Limit im Westen wurde unterschritten
  • Sonnenuntergang: Der Sonnenuntergang wurde erkannt
  • Sturm erkannt: Das konfigurierte Wind-Limit wurde überschritten
  • Sturm vorbei: Das konfigurierte Wind-Limit wurde unterschritten
  • Windalarm Grenze 1 überschritten: Das konfigurierte Wind-Limit für Grenze 1 wurde überschritten
  • Windalarm Grenze 1 unterschritten: Das konfigurierte Wind-Limit für Grenze 1 wurde unterschritten
  • Windalarm Grenze 2 überschritten: Das konfigurierte Wind-Limit für Grenze 2 wurde überschritten
  • Windalarm Grenze 2 unterschritten: Das konfigurierte Wind-Limit für Grenze 2 wurde unterschritten

Proxy

Zusätzlich zur lokalen Wetterstation kann eine Proxy-Wetterstation erstellt werden. Diese ermöglicht den Zugriff auf Daten von Wetterstationen, die sich auf demselben oder auf einem anderen Controller befinden.

Zum Erstellen einer Proxy-Wetterstation zunächst wie bei einer lokalen Wetterstation vorgehen und „Hinzufügen“ auswählen.

Ist auf dem Controller bereits eine Wetterstation eingerichtet oder ein anderes Gerät an der Hauptschnittstelle angeschlossen, wird automatisch ein entsprechender Hinweis angezeigt. Anschließend kann direkt eine Proxy-Wetterstation erstellt werden.

Ist noch keine lokale Wetterstation installiert, im Operator Panel im unteren Bereich den Typ über das Dropdown-Menü auf „Proxy-Wetterstation“ ändern.

Im Parameter Panel befindet sich der Bereich „Verbindung“. Dort müssen die Verbindungsdaten einer lokalen Wetterstation eingetragen werden.

Nach erfolgreicher Konfiguration stehen über die Proxy-Wetterstation dieselben Funktionen wie bei einer lokalen Wetterstation zur Verfügung.

Counter

This app is used when you connect a counter to a digital input. With it's help you can react to the signals send form the counter unit and evaluate them. For example, you can record a power consumption in kW, set various value limits and react to them later in scenes.

The Counter ist located under “all apps” – “Counter”.

The minimum pulse length for a counter connected to a digital module is 100ms. For faster counters, please use the input located on the cpu module.

Create

To use a counter with the corresponding app, it must first be connected to a digital input of the Smart Building Automation system. A digital input on the controller (DI1–DI4) or on a Schrack Smart Building Automation digital module, such as the "D1180" or "D1344", can be used for this purpose. Then follow these steps:

If no counter has been created in the Smart Building Automation system yet, a digital input must first be configured accordingly.

Navigate to the digital inputs under "All Apps" – "Digital Inputs", select the desired input, and open the ParameterPanel.

Under "Mode", select "Counter". The digital input is then configured as a counter and displayed in the "Counter" app.

Configuration

Every Counter allow you to change certain settings, which determine what will be counted (e.g. kWh) and what limits exists.

Pulse value
Choose the significance of the impulse which gets received by the counter. The necessary settings for this are usually listed on the counter device.

Settings
Inverted
If this option is activated, only falling edges will be counted instead of rising edges.

Reserve
Hides this counter from the visualization.

Color
Changes the color of the visible graphs.

Edit count
Here, you can set the current count to a desired value

Show statistics
Choose the graph/chart, which will be displayed in the OperatorPanel.

Limits
You can choose various limits (and according delays) here, which you can then link in scenes. Linkable values are: 'current consumption - upper limit', 'current consumption - lower limit' and 'daily consumption - limit'.

Mode
With this setting you can convert/revert a counter to a digital input or switch

Operation

Once a Counter has been created, you can add additional visual panels. Those grant you an overview about the evaluated values.

To add such a panel, use the button "add panel".

In the popup which will appear, you can choose between several graphs/charts. To do so, you have to select the corresponding Counter under 'choose counter' and then one of the desired charts.

The OperatorPanel gives you an overview about the measured values. The following sections exist:

Status
Gives you information about the total, daily and current consumption. In addition, you can also reset the counter.

Statistic
The graphs/charts which you can activate in the ParamterPanel will be shown here. The statistics which are shown here can also be reset with the corresponding button.

Szenen

Der Zähler bietet folgende Auslöser für Szenen (wenn ...):

  • Grenzwert Gesamtverbrauch überschritten: Der Grenzwerte für den Gesamtverbrauch wurde überschritten
  • Grenzwert Tagesverbrauch überschritten: Der Grenzwert für den Tagesverbrauch wurde überschritten
  • Oberer Grenzwert aktueller Verbrauch überschritten: Der obere Grenzwert für den aktuellen Verbrauch wurde überschritten
  • Unterer Grenzwert aktueller Verbrauch unterschritten: Der untere Grenzwert für den aktuellen Verbrauch wurde unterschritten

Der Zähler bietet folgende Funktionen für Szenen (dann ...):

  • Gesamtverbrauch zurücksetzen: Der Gesamtverbrauchszähler wird zurückgesetzt
  • Tagesverbrauch zurücksetzen: Der Tagesverbrauch wird zurückgesetzt

Clock

The clock lets you create an alarm clock, a timer or a weekly programme. The next chapters explain how to use them.

The clock is located under “all apps” – “clock”.

To create an alarm clock, a timer or a weekly programme, simply open the app “clock” and select “add clock”. A window then opens offering you a selection of elements you can create.

Alarm Clock

The app “alarm clock” lets you create an alarm clock that goes off at the time you define and is shut off after a certain time. An alarm clock is intended to be used with a scene to react to the alarm and the end of the alarm.

Using With A Scene

In order to use this alarm with a scene, it must first be named and then you can click on “add” in the scene’s “IF” and select the app “Clock”, unfold the alarm clock and select either “alarm triggered” or “alarm ended”.

Configuration

To define the alarm time, simply click on the currently defined time and select the time you wish for the alarm. You must also activate this alarm via the option “activate”.

The item “repeat” lets you select which on weekdays should the alarm be repeated. If you only want the alarm to go off once, select the option “just once”.

The length of time the alarm is active can be set under “extended” by activating the option “activate extended settings”. You will need the active alarm time if you want the alarm to last for a specific time. For example, if you have activated the alarm for 8pm with an active time of 10 minutes, then the alarm is active from 8 pm till 8:10 pm and then switches itself off. If you haven’t activated this option then the alarm stops directly after the trigger.

Timer

The app “timer” lets you define a countdown that, once the defined time has expired, can invoke a scene. You can also allocate a signal light to this timer that signals when the time has expired.

Operation

To adjust the time, click on the currently defined timer for this timer in the operator panel under “operation” and change it as you require.

The button “start” is used to start the timer and “reset” to reset the start time. The button “pause” stops the timer and you can continue the timer by pressing “start”.

Using With A Scene

In order to be able to use this timer with a scene, it must have a name. Then you can select the trigger “time expired” in the scene under “IF” and the appropriate action to be carried out when the timer has expired. You can also use the timer in the scene for the “THEN”. This lets you start, stop or reset a timer via a scene.

Configuration

Once you have allocated this timer a name and optionally a room, you can begin with the configuration.

You can add as many lights as you want in the item “signal light” using the button “add”. These lights are intended to flash on and off and the number of flashes can be set via the option “number of flashes”. The duration of each flash can be set via the “duration of signal flash”.

Weekly Program

The app “weekly program” lets you define up to 3 time periods per day in which you can execute actions. In order to be able to carry out an action, a scene must react to the activation and de-activation of the weekly program.

Using With A Scene

In order to be able to use this weekly program, you must give it a name. Once done, you can select the triggers “activated” and “de-activated” in the scene’s “IF” statement. For example, if a time from 9 am to 10 am has been defined for each Monday, then “activated” is invoked at 9 am and “de-activated” is invoked at 10 am. Furthermore you can use the weekly program in the scene for “THEN” by selecting “switch on once” (“switch on once” is explained in the chapter “configuration”).

Creating And Editing Entries

To create an entry in the weekly program, click on “+” for the desired day. This opens a window where you can configure the entry. You have the following possibilities:

Day
The weekday for which this entry is to be created.

No end time
If you only want to define a start point then activate this option. If a point has no end time, then the weekly program is activated after the time for the “runtime for additional trigger” has expired (located in the parameter panel).

From
This is the start point for your entry

Until
This is the end point for your entry

To edit an entry, click on the previously created entry (in the operator panel) and then proceed the same as for creating the entry.

Configuration

Runtime for additional trigger
If the weekly program is activated once via the additional trigger, then the weekly program remains active for the defined time. If you have an entry without end point, then the weekly program also remains active for this time after the defined time has expired.

Additional trigger
You can add as many additional triggers as you wish that trigger the weekly program once.

Kalender

Mit der App „Kalender“ können Kalendertage wie Feiertage oder andere Ereignisse verwaltet werden. Kalenderereignisse können dann als Ausnahmebedingungen in Szenen verwendet werden.

Konfiguration

Sie können einen neuen Kalender unter „Alle Apps“ - „Zeitprogramme“ durch Klick auf „Zeitprogramm hinzufügen“ anlegen.

Um länderspezifische Feiertage automatisch dem Kalender hinzuzufügen, muss das Land ausgewählt werden. Wenn keine Feiertage hinzugefügt werden sollen, kann „Keine Feiertage hinzufügen“ ausgewählt werden.

Feiertage können später jederzeit neu in den Kalender importiert werden.

Wenn die Wochenendtage Samstag oder Sonntag als Kalenderereignis verwendet werden soll, können Sie dies auswählen.

Achtung: Diese Tage werden aus Gründen der Übersichtlichkeit nicht im Kalender aufgelistet.

Nach erfolgreicher Erstellung eines Kalenders kann dieser im Parameter Panel konfiguriert werden. Dabei kann dieser wie gewohnt benannt und einem Bereich hinzugefügt werden.

Durch Deaktivieren des Kalenders werden alle Kalenderereignisse inaktiv.

Zusätzlich können die Einstellungen wie Land oder Wochenendereignisse geändert werden, sowie Feiertage importiert werden.

Bedienung

Im Object Panel des Kalenders ist ersichtlich, ob dieser aktiviert (blau) oder deaktiviert (grau) ist. Aktuelle Kalenderereignisse werden unterhalb des Namens aufgelistet.

Im Operator Panel werden alle Kalenderereignisse dargestellt. Dabei können Sie erkennen, ob es sich um einen Feiertag oder ein selbst hinzugefügtes Ereignis handelt. (Selbst hinzugefügte Ereignisse werden mit einem seitlichen blauen Balken dargestellt). Wiederholende Ereignisse werden mithilfe eines Kreises dargestellt.

Im unteren Bereich können Sie einen neuen Kalendereintrag hinzufügen oder bestehende bearbeiten. Dabei können einzelne Einträge gelöscht oder ignoriert werden.

Szenen

Die konfigurierten Kalender-Ereignisse können als „Bedingungen“ bei den Szenen verwendet werden. Als einfaches Beispiel kann die morgendliche Weckfunktion genannt werden. Die Szenen wird über einen Wecker im „Wenn-Bereich“ aktiviert und schaltet im „Dann-Bereich“ bestimmte Lichter und Beschattungselemente. Diese Funktion ist jedoch an Feiertagen nicht gewünscht, hierzu kann nun der Kalender als „Bedingung“ gesetzt werden.

Szenen

Die Zeitprogramme bieten folgende Auslöser für Szenen (wenn ...):

  • (Wecker) Alarm wurde ausgelöst: Der konfigurierte Alarm wurde ausgelöst
  • (Wecker) Alarm wurde beendet: Der Alarm wurde beendet
  • (Timer) Zeit abgelaufen: Die konfigurierte Timer-Zeit ist abgelaufen
  • (Wochenprogramm) Aktiviert: Eine der konfigurierten Zeiten des Wochenprogramms wurde aktiv
  • (Wochenprogramm) Deaktiviert: Eine der konfigurierten Zeiten des Wochenprogramms wurde inaktiv

Die Zeitprogramme bieten folgende Funktionen für Szenen (dann ...):

  • (Timer) Neu starten: Der Timer wird zurückgesetzt und neu gestartet
  • (Timer) Reset: Der Timer wird zurückgesetzt
  • (Timer) Start: Der Timer wird gestartet
  • (Timer) Stop: Der Timer wird gestoppt
  • (Wochenprogramm) Einmalig einschalten: Einmalig einschalten: Das Wochenprogramm wird einmalig aktiviert

Die Einträge des Jahreskalender können als „Bedingungen“ in Szenen verwendet werden. Die Szene soll zum Beispiel nur auslösen, wenn kein Feiertag ist (Bedingung).

Circulation Pump

“Circulation pump” lets you configure and control the times for suitable pump systems.

These functions are located under “all apps” – “circulation pump”.

Configuration

You can define the operation times for each one of your circulation pumps. This is done by defining the operating times in the operator panel. You can define one or more time intervals for each weekday when you wish the circulation pump to be in operation.

In addition to the operating times, you can also define intervals within the operating times, which trigger activates them, where they are connected and whether they should be put into maintenance mode.

Active interval during operating time
Define the intervals within the operating time you wish to circulation pump to be active.

Additional trigger
Select the trigger and the duration for which the circulation pump should be additional active for a short period of time.

Select socket
Define which socket the circulation pump is connected to.

Maintenance
Switch the circulation pump permanently on or off for maintenance purposes.

Operation

To add a new circulation pump, click on the element “add circulation pump”. The next step is to allocate a name for your circulation pump in the parameter panel. Then you can continue with the configuration (described below).

Szenen

Die Zirkulationspumpe bietet folgende Auslöser für Szenen (wenn ...):

  • Ausgeschaltet: Die Zirkulationspumpe wurde ausgeschaltet
  • Eingeschaltet: Die Zirkulationspumpe wurde eingeschaltet

Die Zirkulationspumpe bietet folgende Funktionen für Szenen (dann ...):

  • Einmalig einschalten: Die Zirkulationspumpe wird zusätzlich einmalig eingeschaltet

Access Control

Erstellen

Nachdem der Fingerscanner an das Schrack Smart Building Automation RS485-Auxiliary-Modul „TA200“ oder an die RS485-Schnittstelle des Controllers angeschlossen wurde, kann er im Smart Building Automation System hinzugefügt werden.

Dazu über den entsprechenden Button ein neues Zutrittssystem anlegen.

Im erscheinenden Popup werden alle erkannten Zutrittssysteme aufgelistet. Das gewünschte System kann durch einen Klick auf den Namen oder das Plus-Symbol hinzugefügt werden.

Sind mehrere Zutrittssysteme vorhanden, kann über den zweiten Button die LED-Anzeige des zugehörigen Systems aktiviert werden, um dieses leichter zu identifizieren.

Nachdem ein System ausgewählt wurde, kann ihm im zweiten Schritt ein Name zugewiesen werden.

Nach Bestätigung der Eingabe wird das Zutrittssystem erstellt und kann anschließend konfiguriert werden.

Konfiguration

Um die Konfiguration des Fingerscanners zu starten, wird das neu erstellte Zutrittssystem ausgewählt und im Parameterpanel zu den Einstellungen navigiert.

Im Bereich „Status“ werden Informationen über die Verbindung zum Zutrittssystem angezeigt.

Bei mehreren vorhandenen Zutrittssystemen kann der Button „Identifizieren“ genutzt werden, um die LEDs des verlinkten Systems aufblinken zu lassen und es zu identifizieren.

Es kann nun mit dem Anlegen von Nutzern begonnen werden, für die Finger oder RFID-Chips eingelernt werden sollen.

Dafür wird auf das Plus-Symbol geklickt.

Der Assistent führt durch die einzelnen Schritte zum Anlegen eines Nutzers und den Einlernvorgang.

Zuerst wird der Systembenutzer ausgewählt, für den Finger oder RFID-Chips eingelernt werden sollen.

Eine Übersicht der bereits eingelernten Finger/Chips wird angezeigt.

Um weitere hinzuzufügen, wird auf das Plus-Symbol geklickt.

Der gewünschte Finger oder RFID-Chip wird ausgewählt und auf „Einlernen“ geklickt.

Der Einlernvorgang beginnt, und der Fingerscanner blinkt orange. Der Finger wird mehrmals langsam über den Scanner gezogen, bis das Gerät blau leuchtet. Der Finger wurde erfolgreich eingelernt. Es können weitere Finger oder RFID-Chips hinzugefügt werden. Sobald alle Eingaben abgeschlossen sind, wird auf „Weiter“ geklickt.

Wenn eine Tür mit Türöffner vorhanden ist, kann diese im nächsten Schritt mit dem Benutzer verknüpft werden. Die Tür wird entsperrt, sobald der Finger oder RFID-Chip des Benutzers erkannt wird.

Durch Klicken auf „Weiter“ wird die Konfiguration abgeschlossen. Änderungen können mit einem Klick auf „Fertig“ bestätigt werden. Es besteht auch die Möglichkeit, zurückzugehen und weitere Finger/RFID-Chips hinzuzufügen.

Alle erstellten Benutzer werden in der Liste des Zutrittssystems angezeigt. Neben jedem Benutzer befindet sich ein Schloss-Symbol, mit dem der Benutzer gesperrt werden kann, wodurch er keine Zutrittsberechtigung mehr hat.

Benutzer können über das X-Symbol gelöscht oder durch einen Klick auf den Namen angepasst werden. Der Schalter „Deaktiviert“ ermöglicht das temporäre Deaktivieren des Zutrittssystems. Sollte das System für eine längere Zeit nicht erreichbar sein, wird es automatisch deaktiviert.

Um später weitere Finger oder RFID-Chips zu einem Benutzer hinzuzufügen, wird der entsprechende Name in der Liste ausgewählt.

In der Ansicht können alle bisher eingelernten Finger/RFID-Chips gelöscht oder für den Türöffner deaktiviert werden. Zudem können verknüpfte Türen hinzugefügt oder entfernt werden.

Das Zutrittssystem kann auch bei der Erstellung von Szenen genutzt werden. Da viele Funktionen an Nutzer gekoppelt sind, befinden sich Auslöser, die einen bestimmten Nutzer betreffen, unter „Benutzer“.

Beispiel:
Um eine Szene zu erstellen, die ausgelöst wird, sobald irgendein Finger erkannt wird, sind die entsprechenden Funktionen unter „Wenn“ → „Apps“ → „Zutrittssystem“ zu finden.

Wenn eine Szene ausgelöst werden soll, sobald ein bestimmter Benutzer oder dessen Finger erkannt wird, befinden sich die Auslöser unter „Wenn“ → „System“ → „Benutzer“.

Szenen

Das Zutrittssystem bietet folgende Auslöser für Szenen (wenn ...):

  • Finger/RFID erkannt: Ein eingelernter Finger, RFID-Token oder RFID-Karte wurde erkannte
  • Finger/RFID nicht erkannt: Der benutze Finger bzw. die RFID-Karte wurden nicht erkannt